메뉴 건너뛰기




Volumn 4786, Issue , 2002, Pages 132-143

Optimization of X-ray spectra for bone mineral density and body composition measurements. Theoretical study and experimental validation

Author keywords

Body composition; Bone mineral density; CdZnTe detector; X ray spectra optimization

Indexed keywords

MATHEMATICAL MODELS; MEDICAL IMAGING; OPTIMIZATION; RADIATION DETECTORS;

EID: 0036980427     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.451534     Document Type: Conference Paper
Times cited : (6)

References (18)
  • 1
    • 0026080670 scopus 로고
    • Theoretical and experimental limits of triple photon energy absorptiometry in the measurement of bone mineral
    • P. O. Kotzki, D. Mariano, and M. Rossi, "Theoretical and experimental limits of triple photon energy absorptiometry in the measurement of bone mineral," Phys.Med.Biol. 36(4), pp. 429-437, 1991.
    • (1991) Phys.Med.Biol. , vol.36 , Issue.4 , pp. 429-437
    • Kotzki, P.O.1    Mariano, D.2    Rossi, M.3
  • 2
    • 0017108614 scopus 로고
    • Energy-selective reconstruction in X-ray computerized tomography
    • R. E. Alvarez and A. Macovski, "Energy-selective reconstruction in X-ray computerized tomography," Phys. Med. Biol. 21(5), pp. 733-744, 1981.
    • (1981) Phys. Med. Biol. , vol.21 , Issue.5 , pp. 733-744
    • Alvarez, R.E.1    Macovski, A.2
  • 3
    • 4243967399 scopus 로고
    • The characterization of materials in multiple energy computerized tomography and digital radiography
    • PhD thesis, University of Virginia
    • J. B. Weaver, The characterization of materials in multiple energy computerized tomography and digital radiography. PhD thesis, University of Virginia, 1983.
    • (1983)
    • Weaver, J.B.1
  • 4
    • 0032404460 scopus 로고    scopus 로고
    • Non destructive chemical identification using an X ray transmission function obtained with the multi-energy method
    • in Hard X-ray and gamma-ray detector physics and applications, F. P. Doty and R. B. Hoover, eds.
    • S. Maitrejean and D. S. D. Perion, "Non destructive chemical identification using an X ray transmission function obtained with the multi-energy method," in Hard X-ray and gamma-ray detector physics and applications, F. P. Doty and R. B. Hoover, eds., Proc. SPIE 3446, pp. 134-152, 1998.
    • (1998) Proc. SPIE , vol.3446 , pp. 134-152
    • Maitrejean, S.1    Perion, D.S.D.2
  • 6
    • 0025059876 scopus 로고
    • Effect of non mineral tissues on measurement of bone mineral content by dual-photon absorptiometry
    • J. A. Sorenson, "Effect of non mineral tissues on measurement of bone mineral content by dual-photon absorptiometry," Med.Phys. 17(5), pp. 905-912, 1990.
    • (1990) Med.Phys. , vol.17 , Issue.5 , pp. 905-912
    • Sorenson, J.A.1
  • 7
    • 58149413803 scopus 로고
    • Photon cross section from 1keV to 100MeV for element Z=1 to Z=100
    • E. Storm and H. I. Israël, "Photon cross section from 1keV to 100MeV for element Z=1 to Z=100," Nuclear Data Tables A7, pp. 565-681, 1969.
    • (1969) Nuclear Data Tables , vol.A7 , pp. 565-681
    • Storm, E.1    Israël, H.I.2
  • 8
    • 0029080928 scopus 로고
    • The European spine phantom - A tool for standardization and quality control in spinal bone mineral measurements by DXA and QCT
    • W. A. Kalender, D. Felsenberg, H. K. Genant, M. Fischer, J. Dequeker, and M. Reve, "The European Spine Phantom - a tool for standardization and quality control in spinal bone mineral measurements by DXA and QCT," European journal of radiology 20, pp. 83-92, 1995.
    • (1995) European Journal of Radiology , vol.20 , pp. 83-92
    • Kalender, W.A.1    Felsenberg, D.2    Genant, H.K.3    Fischer, M.4    Dequeker, J.5    Reve, M.6
  • 9
    • 0001512012 scopus 로고    scopus 로고
    • Sindbad. from CAD model to synthetic radiographs
    • D. O. Thomson and D. Chimenti, eds.; Plenum Press
    • A. Glière, "Sindbad. from CAD model to synthetic radiographs," in Review of Progress in Quantitative Nondestructive Evaluation, D. O. Thomson and D. Chimenti, eds., 17A, pp. 387-394, Plenum Press, 1998.
    • (1998) Review of Progress in Quantitative Nondestructive Evaluation , vol.17 A , pp. 387-394
    • Glière, A.1
  • 10
    • 0026517504 scopus 로고
    • Systematic bias in basis material decomposition applied to quantitative dual-energy x-ray imaging
    • E. L. Gingold and B. H. Hasegawa, "Systematic bias in basis material decomposition applied to quantitative dual-energy x-ray imaging," Med. Phys. 19(1), pp. 25-33, 1992.
    • (1992) Med. Phys. , vol.19 , Issue.1 , pp. 25-33
    • Gingold, E.L.1    Hasegawa, B.H.2
  • 11
    • 0019450609 scopus 로고
    • A method for selective tissue and bone visualization using dual energy scanned projection radiography
    • W. R. Brody, G. Butt, A. Hall, and A. Macovski, "A method for selective tissue and bone visualization using dual energy scanned projection radiography," Med. Phys. 8(3), pp. 353-357, 1981.
    • (1981) Med. Phys. , vol.8 , Issue.3 , pp. 353-357
    • Brody, W.R.1    Butt, G.2    Hall, A.3    Macovski, A.4
  • 12
    • 0019389495 scopus 로고
    • Generalized image combination in dual KVP digital radiography
    • L. A. Lehman, R. E. Alvarez, A. Macovski, and W. R. Brody, "Generalized image combination in dual KVP digital radiography," Med. Phys. 8(5), pp. 659-667, 1981.
    • (1981) Med. Phys. , vol.8 , Issue.5 , pp. 659-667
    • Lehman, L.A.1    Alvarez, R.E.2    Macovski, A.3    Brody, W.R.4
  • 13
    • 0026545813 scopus 로고
    • Evaluation of a new set of calibration standards for the measurement of fat content via DPA and DXA
    • M. M. Goodsitt, "Evaluation of a new set of calibration standards for the measurement of fat content via DPA and DXA," Med. Phys. 19(1), pp. 35-44, 1992.
    • (1992) Med. Phys. , vol.19 , Issue.1 , pp. 35-44
    • Goodsitt, M.M.1
  • 14
    • 0031912326 scopus 로고    scopus 로고
    • Analytic and quantitative exposition of patient-specific systematic inaccuracies inherent in planar DXA-derived in vivo BMD measurements
    • H. H. Bolotin, "Analytic and quantitative exposition of patient-specific systematic inaccuracies inherent in planar DXA-derived in vivo BMD measurements," Med. Phys. 25(2), pp. 139-151, 1997.
    • (1997) Med. Phys. , vol.25 , Issue.2 , pp. 139-151
    • Bolotin, H.H.1
  • 15
    • 0033233339 scopus 로고    scopus 로고
    • Simulation studies of optimum energies for DXA: Dependence on tissue type, patient size and dose model
    • G. J. Michael and C. J. Hendersen, "Simulation studies of optimum energies for DXA: dependence on tissue type, patient size and dose model," Australas. Phys. Eng. Med. 22, pp. 126-135, 1999.
    • (1999) Australas. Phys. Eng. Med. , vol.22 , pp. 126-135
    • Michael, G.J.1    Hendersen, C.J.2
  • 16
    • 0031936250 scopus 로고    scopus 로고
    • Measurement of bone mineral using multiple-energy X-ray absorptiometry
    • J. Swanpalmer, R. Kullenberg, and T. Hansson, "Measurement of bone mineral using multiple-energy X-ray absorptiometry," Phys. Med. Biol. 43, pp. 379-387, 1998.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 379-387
    • Swanpalmer, J.1    Kullenberg, R.2    Hansson, T.3
  • 17
    • 0024543815 scopus 로고
    • Simulation studies of dual-energy X-ray absorptiometry
    • J. A. Sorenson, P. R. Duke, and S. Smith, "Simulation studies of dual-energy X-ray absorptiometry," Med. Phys. 16(1), pp. 75-80, 1989.
    • (1989) Med. Phys. , vol.16 , Issue.1 , pp. 75-80
    • Sorenson, J.A.1    Duke, P.R.2    Smith, S.3
  • 18
    • 0034383149 scopus 로고    scopus 로고
    • Correction for escape in X-ray spectra measured by NaI scintillation counters
    • S. Steenstrup, L. Gerward, K. K. Hansen, and S. K. Jensen, "Correction for escape in X-ray spectra measured by NaI scintillation counters," X-ray spectrometry 29, pp. 249-252, 2000.
    • (2000) X-Ray Spectrometry , vol.29 , pp. 249-252
    • Steenstrup, S.1    Gerward, L.2    Hansen, K.K.3    Jensen, S.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.