메뉴 건너뛰기




Volumn 22, Issue 4, 1999, Pages 126-135

Simulation studies of optimum energies for DXA: Dependence on tissue type, patient size and dose model

Author keywords

Dose; Dual energy x ray absorptiometry; Monte Carlo modelling; Optimum energies; Tissue type

Indexed keywords

ADIPOSE TISSUE; ARTICLE; BIOLOGICAL MODEL; BODY CONSTITUTION; BONE DENSITY; CONNECTIVE TISSUE; FEMUR NECK; HUMAN; IMAGE QUALITY; METHODOLOGY; MONTE CARLO METHOD; RADIATION DOSE; RADIODENSITOMETRY; RADIOGRAPHY;

EID: 0033233339     PISSN: 01589938     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (20)
  • 1
    • 0029947590 scopus 로고    scopus 로고
    • Dual-energy x-ray absorptiometry and body composition
    • Laskey, M.A., Dual-energy x-ray absorptiometry and body composition. Nutrition Vol: 12, No: 1, 45-51, 1996.
    • (1996) Nutrition , vol.12 , Issue.1 , pp. 45-51
    • Laskey, M.A.1
  • 2
    • 0029314411 scopus 로고
    • Radiographic measurement of bone mineral: Reviewing dual-energy x-ray absorptiometry
    • Sim, L.H. and van Doom, T., Radiographic measurement of bone mineral: reviewing dual-energy x-ray absorptiometry. Austral. Phys. Eng. Sci. Med., Vol: 18, No:2, 65-80, 1995.
    • (1995) Austral. Phys. Eng. Sci. Med. , vol.18 , Issue.2 , pp. 65-80
    • Sim, L.H.1    Van Doom, T.2
  • 4
    • 0016611462 scopus 로고
    • Optimum energies for the measurement of bone mineral and fat fractions
    • Watt, D.E., Optimum energies for the measurement of bone mineral and fat fractions. British Journal of Radiology, Vol:48, 265-274, 1975.
    • (1975) British Journal of Radiology , vol.48 , pp. 265-274
    • Watt, D.E.1
  • 5
    • 0017526106 scopus 로고
    • Applications of filtered bremsstrahlung spectra in radiologic studies part I: Spectrum properties and optimal energies
    • Chan, J.L.H. and Macovski, A., Applications of filtered bremsstrahlung spectra in radiologic studies part I: Spectrum properties and optimal energies. IEEE Transactions on Nuclear Science, NS-24, Vol:4, 1968-76, 1977.
    • (1977) IEEE Transactions on Nuclear Science, NS-24 , vol.4 , pp. 1968-1976
    • Chan, J.L.H.1    Macovski, A.2
  • 6
    • 0018014157 scopus 로고
    • Optimum energies for the measurement of bone mineral and fat fractions
    • Letter to Editor
    • Bolin, F.P. and Preuss, L.E., Optimum energies for the measurement of bone mineral and fat fractions. Letter to Editor, British Journal of Radiology, Vol:51, 750, 1978.
    • (1978) British Journal of Radiology , vol.51 , pp. 750
    • Bolin, F.P.1    Preuss, L.E.2
  • 7
    • 84921366732 scopus 로고
    • Optimised kVp, filtration and detection parameters for dual-energy imaging
    • Rutt, B.K., Optimised kVp, filtration and detection parameters for dual-energy imaging. Medical Physics, Vol:12, No:4, 536, 1985.
    • (1985) Medical Physics , vol.12 , Issue.4 , pp. 536
    • Rutt, B.K.1
  • 8
    • 0024543815 scopus 로고
    • Simulation studies of dual-energy x-ray absorptiometry
    • Sorensen, J.A., Duke, P.R. and Smith, S.W., Simulation studies of dual-energy x-ray absorptiometry. Medical Physics, Vol: 16, No:1, 75-80, 1989.
    • (1989) Medical Physics , vol.16 , Issue.1 , pp. 75-80
    • Sorensen, J.A.1    Duke, P.R.2    Smith, S.W.3
  • 9
    • 0026091293 scopus 로고
    • Bone mineral densilometry with x-ray and radionuclide sources: A theoretical comparison
    • Chakraborty, D.P. and Barnes, G.T., Bone mineral densilometry with x-ray and radionuclide sources: A theoretical comparison. Medical Physics Vol: 18, No:5, 978-84, 1991.
    • (1991) Medical Physics , vol.18 , Issue.5 , pp. 978-984
    • Chakraborty, D.P.1    Barnes, G.T.2
  • 10
    • 0024336121 scopus 로고
    • X-ray energy optimisation in computed microtomography
    • Spanne, P., X-ray energy optimisation in computed microtomography. Phys. Med. Biol., Vol:34, No:6, 679-690, 1989.
    • (1989) Phys. Med. Biol. , vol.34 , Issue.6 , pp. 679-690
    • Spanne, P.1
  • 11
    • 0011956937 scopus 로고    scopus 로고
    • Bone densitometry and morphometry
    • Kalendar, W.A. and Engelke, K., Bone densitometry and morphometry, ICRU News, Vol:97, No:2, 9-14, 1997.
    • (1997) ICRU News , vol.97 , Issue.2 , pp. 9-14
    • Kalendar, W.A.1    Engelke, K.2
  • 12
    • 0026748608 scopus 로고
    • Dual energy x-ray absorptiometry: The effects of beam hardening on bone density measurements
    • Blake, G.M., McKeeney, D.B., Chhaya, S.C., Ryan, P.J. and Fogelman, I., Dual energy x-ray absorptiometry: The effects of beam hardening on bone density measurements. Medical Physics, Vol: 19, No:2, 459-465, 1992.
    • (1992) Medical Physics , vol.19 , Issue.2 , pp. 459-465
    • Blake, G.M.1    McKeeney, D.B.2    Chhaya, S.C.3    Ryan, P.J.4    Fogelman, I.5
  • 13
    • 0026802211 scopus 로고
    • Photon absorption measurements of bone density in the presence of scattered radiation
    • Mooney, M.J. and Speller, R.D., Photon absorption measurements of bone density in the presence of scattered radiation. Phys. Med. Biol., Vol:37, No: 10, 1873-1882, 1992.
    • (1992) Phys. Med. Biol. , vol.37 , Issue.10 , pp. 1873-1882
    • Mooney, M.J.1    Speller, R.D.2
  • 15
    • 8744267398 scopus 로고
    • Tissue substitutes in radiation dosimetry and measurement. International Commission on Radiation Units and Measurements, Bethesda, Md., U.S.A.
    • ICRU Report 44, Tissue substitutes in radiation dosimetry and measurement. International Commission on Radiation Units and Measurements, Bethesda, Md., U.S.A. 1989.
    • (1989) ICRU Report , vol.44
  • 16
    • 0026611965 scopus 로고
    • A phantom for standardisation and quality control in spinal bone mineral measurements by QCT and DXA: Design considerations and specifications
    • Kalender, W.A., A phantom for standardisation and quality control in spinal bone mineral measurements by QCT and DXA: Design considerations and specifications. Medical Physics, Vol: 19, No:3, 583-586, 1992.
    • (1992) Medical Physics , vol.19 , Issue.3 , pp. 583-586
    • Kalender, W.A.1
  • 17
    • 0001540751 scopus 로고    scopus 로고
    • Single - And dual-energy x-ray absorptiometry
    • edited by Genant HK, Guglielmi G and Jergas M, Springer-Verlag, Berlin
    • Adams, J.E., Single - and dual-energy x-ray absorptiometry. In Bone Density and Osteoporosis, edited by Genant HK, Guglielmi G and Jergas M, Springer-Verlag, Berlin, 1998.
    • (1998) Bone Density and Osteoporosis
    • Adams, J.E.1
  • 20
    • 0018843471 scopus 로고
    • Optimum energies for dual-energy computed tomography
    • Talbert, A.J., Brooks, R.A. and Morgenthaler, D.G., Optimum energies for dual-energy computed tomography. Phys. Med. Biol., Vol:25, No:2, 261-269, 1980.
    • (1980) Phys. Med. Biol. , vol.25 , Issue.2 , pp. 261-269
    • Talbert, A.J.1    Brooks, R.A.2    Morgenthaler, D.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.