-
1
-
-
0025894848
-
Alanine ESR dosimetry: An assessment of peak-to-peak evaluation
-
Ahlers F.J., Schneider C.C.J.: Alanine ESR dosimetry: an assessment of peak-to-peak evaluation, Radiat. Prot. Dos. 1991, 37, 2, 117-122.
-
(1991)
Radiat. Prot. Dos.
, vol.37
, pp. 117-122
-
-
Ahlers, F.J.1
Schneider, C.C.J.2
-
4
-
-
0023908769
-
The energy response of agar-alanine phantom dosimeter to gamma radiation
-
Ciesielski B., Wielopolski L., Reinstein L.E.: The energy response of agar-alanine phantom dosimeter to gamma radiation, Med. Phys. 1988, 15, 3, 380-383.
-
(1988)
Med. Phys.
, vol.15
, pp. 380-383
-
-
Ciesielski, B.1
Wielopolski, L.2
Reinstein, L.E.3
-
5
-
-
0027753975
-
Energy response of agar-alanine free radical dosimetry to therapeutic electron beams
-
Ciesielski B., Reinstein L.E., Meek A.G., Wielopolski L.: Energy response of agar-alanine free radical dosimetry to therapeutic electron beams, Med. Phys. 1993, 20, 5, 1453-1456.
-
(1993)
Med. Phys.
, vol.20
, pp. 1453-1456
-
-
Ciesielski, B.1
Reinstein, L.E.2
Meek, A.G.3
Wielopolski, L.4
-
6
-
-
0032931222
-
Alanine/EPR dosimetry in brachytherapy
-
De Angelis C., Onori S., Petetti E. et al.: Alanine/EPR dosimetry in brachytherapy, Phys. Med. Biol. 1999, 44, 1181-1191.
-
(1999)
Phys. Med. Biol.
, vol.44
, pp. 1181-1191
-
-
De Angelis, C.1
Onori, S.2
Petetti, E.3
-
7
-
-
0031693650
-
A high sesitivity EPR technique for alanine dosimetry
-
Haskell E.H., Hayes R.B., Kenner G.H: A high sesitivity EPR technique for alanine dosimetry, Radiat. Prot. Dosim. 1998, 77, 1/2, 43-49.
-
(1998)
Radiat. Prot. Dosim.
, vol.77
, Issue.1-2
, pp. 43-49
-
-
Haskell, E.H.1
Hayes, R.B.2
Kenner, G.H.3
-
9
-
-
0012726583
-
Metoda bezpósredniego pomiaru dawki promieniowania X lub gamma u chorych napromienianych wia̧zkami zewnȩtrznymi (dozymetria in vivo)
-
Łobodziec W., Orlef A., Maniakowski Z.: Metoda bezpósredniego pomiaru dawki promieniowania X lub gamma u chorych napromienianych wia̧zkami zewnȩtrznymi (dozymetria in vivo), Nowotwory 1996, 46, 67-78.
-
(1996)
Nowotwory
, vol.46
, pp. 67-78
-
-
Łobodziec, W.1
Orlef, A.2
Maniakowski, Z.3
-
11
-
-
0020983087
-
A system of transfer dosimetry in radiation processing
-
Regulla D.F., Deffner U.: A system of transfer dosimetry in radiation processing, Radiat. Phys. Chem. 1983, 22, 3-5, 305-309.
-
(1983)
Radiat. Phys. Chem.
, vol.22
, Issue.3-5
, pp. 305-309
-
-
Regulla, D.F.1
Deffner, U.2
-
12
-
-
0012637334
-
In vivo dosimetry with L-alanine: A fesibility study and possible aplications in brachytherapy
-
Wagner J.P., Delpech L.P., Marchioni F. et al.: In vivo dosimetry with L-alanine: a fesibility study and possible aplications in brachytherapy, Radiother. Oncol. 1994, 31, 22.
-
(1994)
Radiother Oncol
, vol.31
, pp. 22
-
-
Wagner, J.P.1
Delpech, L.P.2
Marchioni, F.3
-
13
-
-
0004618458
-
-
ed. C. G. Orton, Plenum Press, New York, London
-
White D.R., Mortin R.J.: Antropomorphic Phantom Materials, Progress in Medical Radiation Physics, ed. C. G. Orton, Plenum Press, New York, London 1982, 133-193.
-
(1982)
Antropomorphic Phantom Materials, Progress in Medical Radiation Physics
, pp. 133-193
-
-
White, D.R.1
Mortin, R.J.2
-
14
-
-
0023492781
-
Continuous three-dimensional radiation dosimetry in tissue-equivalent phantoms using electron paramagnetic resonance in Lalanine
-
Wielopolski L., Maryański M., Ciesielski B. et al.: Continuous three-dimensional radiation dosimetry in tissue-equivalent phantoms using electron paramagnetic resonance in Lalanine, Med. Phys. 1987, 14, 4, 646-652.
-
(1987)
Med. Phys.
, vol.14
, pp. 646-652
-
-
Wielopolski, L.1
Maryański, M.2
Ciesielski, B.3
-
15
-
-
0024840273
-
Influence of the radiation temperature on free redical response of alanine
-
Wieser A., Siegele R., Regulla D.F.: Influence of the radiation temperature on free redical response of alanine, Appl. Radiat. Isot. 1989, 40, 10-12, 957-959.
-
(1989)
Appl. Radiat. Isot.
, vol.40
, Issue.10-12
, pp. 957-959
-
-
Wieser, A.1
Siegele, R.2
Regulla, D.F.3
-
16
-
-
0027476301
-
The influence of non-radiation induced ESR background signal from paraffin-alanine probes for dosimetry in the radiotherapy dose range
-
Wieser A., Lettau C., Fill U., Regulla D.F.: The influence of non-radiation induced ESR background signal from paraffin-alanine probes for dosimetry in the radiotherapy dose range, Appl. Radiat. Isot. 1993, 44, 1/2, 59-65.
-
(1993)
Appl. Radiat. Isot.
, vol.44
, Issue.1-2
, pp. 59-65
-
-
Wieser, A.1
Lettau, C.2
Fill, U.3
Regulla, D.F.4
|