메뉴 건너뛰기




Volumn 77, Issue 1-2, 1998, Pages 43-49

A high sensitivity EPR technique for alanine dosimetry

Author keywords

[No Author keywords available]

Indexed keywords

ALANINE; MANGANESE;

EID: 0031693650     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.rpd.a032293     Document Type: Conference Paper
Times cited : (42)

References (13)
  • 1
    • 0030293959 scopus 로고    scopus 로고
    • Progress Towards an Alanine/ESR Therapy Level Reference Dosimetry Service at NPL
    • Sharpe, P. H. G., Rajendran, K. and Sephton, J. P. Progress Towards an Alanine/ESR Therapy Level Reference Dosimetry Service at NPL. Appl. Radiat. Isot. 47, 1171-1176 (1996).
    • (1996) Appl. Radiat. Isot. , vol.47 , pp. 1171-1176
    • Sharpe, P.H.G.1    Rajendran, K.2    Sephton, J.P.3
  • 2
    • 0030294901 scopus 로고    scopus 로고
    • Alanine-ESR Dosimetry for Radiotherapy. IAEA Experience
    • Mehta, K. and Girzikowski, R. Alanine-ESR Dosimetry for Radiotherapy. IAEA Experience. Appl. Radiat. Isot. 47, 1189-1192 (1996).
    • (1996) Appl. Radiat. Isot. , vol.47 , pp. 1189-1192
    • Mehta, K.1    Girzikowski, R.2
  • 3
    • 0030293060 scopus 로고    scopus 로고
    • Numerical Signal Treatment for Optimized Alanine/ESR Dosimetry in the Therapy-Level Dose Range
    • Ruckerbauer, F., Sprunck, M. and Regulla, D. F. Numerical Signal Treatment for Optimized Alanine/ESR Dosimetry in the Therapy-Level Dose Range. Appl. Radiat. Isot. 47, 1263-1268 (1996).
    • (1996) Appl. Radiat. Isot. , vol.47 , pp. 1263-1268
    • Ruckerbauer, F.1    Sprunck, M.2    Regulla, D.F.3
  • 4
    • 0030294716 scopus 로고    scopus 로고
    • Application of an Alanine Dosimetry System for Industrial Irradiation and Radiation Protection
    • Gohs, U. Application of an Alanine Dosimetry System for Industrial Irradiation and Radiation Protection. Appl. Radiat. Isot. 47, 1169-1170 (1996).
    • (1996) Appl. Radiat. Isot. , vol.47 , pp. 1169-1170
    • Gohs, U.1
  • 5
    • 0030293908 scopus 로고    scopus 로고
    • The Extension of the Range of NIM Alanine/ESR Dosimetric System to Therapy Level
    • Gao Juncheng and Wang Zaiyong. The Extension of the Range of NIM Alanine/ESR Dosimetric System to Therapy Level. Appl. Radiat. Isot. 47, 1193-1196 (1996).
    • (1996) Appl. Radiat. Isot. , vol.47 , pp. 1193-1196
    • Gao, J.1    Wang, Z.2
  • 6
    • 0030293066 scopus 로고    scopus 로고
    • One Year of Experience with Alanine Dosimetry in Radiatherapy
    • Schaeken, B. and Scalliet, P. One Year of Experience with Alanine Dosimetry in Radiatherapy. Appl. Radiat. Isot. 47, 1177-1182 (1996).
    • (1996) Appl. Radiat. Isot. , vol.47 , pp. 1177-1182
    • Schaeken, B.1    Scalliet, P.2
  • 8
    • 0027476301 scopus 로고
    • The Influence of Non-Radiation Induced ESR Background Signal from Paraffin-Alanine Probes for Dosimetry in the Radiotherapy Dose Range
    • Wieser, A., Lettau, C., Fill, U. and Regulla, D. The Influence of Non-Radiation Induced ESR Background Signal from Paraffin-Alanine Probes for Dosimetry in the Radiotherapy Dose Range. Appl. Radiat. Isot. 44, 59-66 (1993).
    • (1993) Appl. Radiat. Isot. , vol.44 , pp. 59-66
    • Wieser, A.1    Lettau, C.2    Fill, U.3    Regulla, D.4
  • 9
    • 0030294888 scopus 로고    scopus 로고
    • The NIM Alanine-ESR Dosimetric System for Industrial Radiation Processing
    • Gao Juncheng. The NIM Alanine-ESR Dosimetric System for Industrial Radiation Processing. Appl Radiat. Isot. 47, 1161-1164 (1996).
    • (1996) Appl Radiat. Isot. , vol.47 , pp. 1161-1164
    • Gao, J.1
  • 10
    • 0031122791 scopus 로고    scopus 로고
    • Improved Accuracy of EPR Dosimetry Using a Constant Rotation Goniometer
    • Haskell, E. H., Hayes, R. B. and Kenner, G. H. Improved Accuracy of EPR Dosimetry Using a Constant Rotation Goniometer. Radiat. Meas. 27, 325-329 (1997).
    • (1997) Radiat. Meas. , vol.27 , pp. 325-329
    • Haskell, E.H.1    Hayes, R.B.2    Kenner, G.H.3
  • 12
    • 0024814955 scopus 로고
    • Alanine in High-Dose Dosimetry: Spectrophotometric and Electrochemical Readout Procedures Compared with ESR
    • Van Laere, K., Buysse, J. and Berkvens, P. Alanine in High-Dose Dosimetry: Spectrophotometric and Electrochemical Readout Procedures Compared with ESR. Appl. Radiat. Isot. 40, 885-896 (1989).
    • (1989) Appl. Radiat. Isot. , vol.40 , pp. 885-896
    • Van Laere, K.1    Buysse, J.2    Berkvens, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.