메뉴 건너뛰기




Volumn 32, Issue 12, 2002, Pages 896-901

Detection of rib fractures in an abused infant using digital radiography: A laboratory study

Author keywords

Child abuse; Digital radiography; Fractures

Indexed keywords

ARTICLE; AUTOPSY; BONE INJURY; CHILD ABUSE; CONTROLLED STUDY; DIAGNOSTIC IMAGING; DIAGNOSTIC TEST; DIGITAL RADIOGRAPHY; HUMAN; IMAGE ANALYSIS; IMAGING SYSTEM; INFANT; INTERMETHOD COMPARISON; LABORATORY TEST; MEDICAL ASSESSMENT; MEDICAL INSTRUMENTATION; PEDIATRICS; PRIORITY JOURNAL; PROBABILITY; RADIATION EXPOSURE; RADIOLOGIST; RIB FRACTURE; ROC CURVE; SCREENING TEST; X RAY FILM;

EID: 0036946817     PISSN: 03010449     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00247-002-0778-4     Document Type: Article
Times cited : (20)

References (29)
  • 1
    • 0012388299 scopus 로고    scopus 로고
    • American College of Radiology ACR standards Res. 22. Reston, Va
    • American College of Radiology (1997) ACR standards. Standards for skeletal surveys in children, Res. 22. Reston, Va, p 23
    • (1997) Standards for Skeletal Surveys in Children , pp. 23
  • 2
    • 0031740171 scopus 로고    scopus 로고
    • Skeletal surveys for child abuse: Comparison of interpretation using digitized images and screen-film radiographs
    • Youmans DC, Don S, Hildebolt C, et al (1998) Skeletal surveys for child abuse: comparison of interpretation using digitized images and screen-film radiographs. AJR 171:1415-1419
    • (1998) AJR , vol.171 , pp. 1415-1419
    • Youmans, D.C.1    Don, S.2    Hildebolt, C.3
  • 3
    • 0012558845 scopus 로고    scopus 로고
    • Skeletal surveys using computed radiography (CR) in suspected child abuse: Does CR meet the American College of Radiology (ACR) standards?
    • Oregon Health Sciences University, Portland, USA
    • Brown PH, Silberberg PJ, Primack SL, et al(2001) Oregon Health Sciences University, Portland, USA. Skeletal surveys using computed radiography (CR) in suspected child abuse: does CR meet the American College of Radiology (ACR) standards? Pediatr Radiol [Suppl 1]31:36
    • (2001) Pediatr Radiol , Issue.SUPPL. 1 , pp. 31-36
    • Brown, P.H.1    Silberberg, P.J.2    Primack, S.L.3
  • 4
    • 0033919453 scopus 로고    scopus 로고
    • Selenium-based digital radiography in the detection of bone lesions: Preliminary experience with experimentally created defects
    • Ludwig K, Link TM, Feibich M, et al (2000) Selenium-based digital radiography in the detection of bone lesions: preliminary experience with experimentally created defects. Radiology 216:220-224.
    • (2000) Radiology , vol.216 , pp. 220-224
    • Ludwig, K.1    Link, T.M.2    Feibich, M.3
  • 5
    • 0342264667 scopus 로고    scopus 로고
    • Simulated bone erosions in a hand phantom: Detection with conventional screen-film technology versus cesium iodide-amorphous silicon flat-panel detector
    • Strotzer M, Volk M, Wild T, et al (2000) Simulated bone erosions in a hand phantom: detection with conventional screen-film technology versus cesium iodide-amorphous silicon flat-panel detector. Radiology 215:512-515
    • (2000) Radiology , vol.215 , pp. 512-515
    • Strotzer, M.1    Volk, M.2    Wild, T.3
  • 6
    • 0028101786 scopus 로고
    • Artificial bone erosions: Detection with magnification radiography versus conventional high-resolution radiography
    • Link TM, Rummeny EJ, Lenzen H, et al (1994) Artificial bone erosions: detection with magnification radiography versus conventional high-resolution radiography. Radiology 192:861-864
    • (1994) Radiology , vol.192 , pp. 861-864
    • Link, T.M.1    Rummeny, E.J.2    Lenzen, H.3
  • 7
    • 0025180192 scopus 로고
    • Storage phosphor versus screen-film radiography: Effect of varying exposure parameters and unsharp mask filtering on the detectability of cortical bone defects
    • Prokop M, Galanski M, Oestmann JW, et al (1990) Storage phosphor versus screen-film radiography: effect of varying exposure parameters and unsharp mask filtering on the detectability of cortical bone defects. Radiology 177:109-113
    • (1990) Radiology , vol.177 , pp. 109-113
    • Prokop, M.1    Galanski, M.2    Oestmann, J.W.3
  • 8
    • 0029891421 scopus 로고    scopus 로고
    • Digital luminescence radiography in comparison with the conventional film-screen technique in diagnosis of fractures
    • Fink U, Schwerdtfeger J, Fink BK, et al (1996) Digital luminescence radiography in comparison with the conventional film-screen technique in diagnosis of fractures. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 164:275-280
    • (1996) Rofo. Fortschr. Geb. Rontgenstr. Neuen. Bildgeb. Verfahr. , vol.164 , pp. 275-280
    • Fink, U.1    Schwerdtfeger, J.2    Fink, B.K.3
  • 9
    • 0029329442 scopus 로고
    • Multireader, multicase receiver operating characteristic methodology a bootstrap analysis
    • Dorfman DD, Berbaum KS, Lenth RV (1995) Multireader, multicase receiver operating characteristic methodology a bootstrap analysis. Acad Radiol 2:626-633
    • (1995) Acad Radiol. , vol.2 , pp. 626-633
    • Dorfman, D.D.1    Berbaum, K.S.2    Lenth, R.V.3
  • 11
    • 0020524559 scopus 로고
    • A method of comparing the areas under receiver operating characteristic curves derived from the same cases
    • Hanley JA, McNeil BJ (1983) A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 148:839-843
    • (1983) Radiology , vol.148 , pp. 839-843
    • Hanley, J.A.1    McNeil, B.J.2
  • 12
    • 0003476298 scopus 로고    scopus 로고
    • US Department of Health and Human Services US Government Printing Office, Washington DC
    • US Department of Health and Human Services (1996) The third national incidence study of child abuse and neglect. US Government Printing Office, Washington DC
    • (1996) The Third National Incidence Study of Child Abuse and Neglect
  • 13
    • 0027459332 scopus 로고
    • Estimates of fatal child abuse and neglect, United States, 1979 through 1988
    • McClain PW, Sacks, JJ, Foehlke, et al (1993) Estimates of fatal child abuse and neglect, United States, 1979 through 1988. Pediatrics 91:338-343
    • (1993) Pediatrics , vol.91 , pp. 338-343
    • McClain, P.W.1    Sacks, J.J.2    Foehlke, A.3
  • 14
    • 0029118228 scopus 로고
    • Inflicted skeletal injury: A postmortem radiologic-histopathologic study in 31 infants
    • Kleinman PK, Marks SC Jr, Richmond JM, et al (1995) Inflicted skeletal injury: a postmortem radiologic-histopathologic study in 31 infants. AJR 165:647-650
    • (1995) AJR , vol.165 , pp. 647-650
    • Kleinman, P.K.1    Marks S.C., Jr.2    Richmond, J.M.3
  • 15
    • 0023865477 scopus 로고
    • Factors affecting visualization of posterior rib fractures in abused infants
    • Kleinman PK, Marks SC Jr, Adams VI, et al (1988) Factors affecting visualization of posterior rib fractures in abused infants. AJR 150:635-638
    • (1988) AJR , vol.150 , pp. 635-638
    • Kleinman, P.K.1    Marks S.C., Jr.2    Adams, V.I.3
  • 16
    • 0029787389 scopus 로고    scopus 로고
    • Rib fractures in 31 abused infants: Postmortem radiologic-histopathologic study
    • Kleinman PK, Marks SC Jr, Nimkin K, et al (1996) Rib fractures in 31 abused infants: postmortem radiologic-histopathologic study. Radiology 200:807-810
    • (1996) Radiology , vol.200 , pp. 807-810
    • Kleinman, P.K.1    Marks S.C., Jr.2    Nimkin, K.3    et, al..4
  • 17
    • 0025062583 scopus 로고
    • Serial abuse in children who are shaken
    • Alexander R, Crabbe L, Sato Y, et al (1990) Serial abuse in children who are shaken. AJDC 144:58-60
    • (1990) AJDC , vol.144 , pp. 58-60
    • Alexander, R.1    Crabbe, L.2    Sato, Y.3
  • 18
    • 0033623770 scopus 로고    scopus 로고
    • Performance of a 41×41-cm2 amorphous silicon flat panel x-ray detector for radiographic imaging applications
    • Granfors PR, Aufrichtig R (2000) Performance of a 41×41-cm2 amorphous silicon flat panel x-ray detector for radiographic imaging applications. Med Phys 27:1324-31
    • (2000) Med. Phys. , vol.27 , pp. 1324-1331
    • Granfors, P.R.1    Aufrichtig, R.2
  • 19
    • 0033849943 scopus 로고    scopus 로고
    • Mammographic imaging with a small format CCD-based digital cassette: Physical characteristics of a clinical system
    • Vedantham S, Karellas A, Suryanarayanan S, et al (2000) Mammographic imaging with a small format CCD-based digital cassette: physical characteristics of a clinical system. Med Phys 27:1832-40
    • (2000) Med. Phys. , vol.27 , pp. 1832-1840
    • Vedantham, S.1    Karellas, A.2    Suryanarayanan, S.3
  • 20
    • 0034068552 scopus 로고    scopus 로고
    • Full breast digital mammographic imaging with an amorphous silicon-based flat panel detector: Physical characteristics of a clinical prototype
    • Vedantham S, Karellas A, Suryanarayanan S, et al (2000) Full breast digital mammographic imaging with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype. Med Phys 27:558-567
    • (2000) Med. Phys. , vol.27 , pp. 558-567
    • Vedantham, S.1    Karellas, A.2    Suryanarayanan, S.3
  • 21
    • 0035119131 scopus 로고    scopus 로고
    • Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography
    • Floyd CE Jr, Warp RJ, Dobbins JT 3rd, et al (2001) Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography. Radiology 218:683-8
    • (2001) Radiology , vol.218 , pp. 683-688
    • Floyd C.E., Jr.1    Warp, R.J.2    Dobbins J.T. III3    et al4
  • 22
    • 0033983981 scopus 로고    scopus 로고
    • Signal-to-noise ratio and spatial resolution in x-ray electronic imagers: Is the MTF a relevant parameter?
    • Moy JP (2000) Signal-to-noise ratio and spatial resolution in x-ray electronic imagers: is the MTF a relevant parameter? Med Phys 27:86-93
    • (2000) Med. Phys. , vol.27 , pp. 86-93
    • Moy, J.P.1
  • 23
    • 0026158277 scopus 로고
    • Detection of small bone lesions with digital radiography using storage phosphors
    • Salvini E, Zincone G, Fossati N (1991) Detection of small bone lesions with digital radiography using storage phosphors. Radiol Med 81:705-708
    • (1991) Radiol. Med. , vol.81 , pp. 705-708
    • Salvini, E.1    Zincone, G.2    Fossati, N.3
  • 24
    • 0027938722 scopus 로고
    • Use of digital photoluminescence radiography in traumatology. Report of experiences
    • Braunschweig R, Rether J, Niemeier R, et al (1994) Use of digital photoluminescence radiography in traumatology. Report of experiences. Unfallchirurg 97:337-342
    • (1994) Unfallchirurg. , vol.97 , pp. 337-342
    • Braunschweig, R.1    Rether, J.2    Niemeier, R.3
  • 25
    • 0028468815 scopus 로고
    • Film-screen vs. digital radiography in rheumatoid arthritis of the hand. An ROC analysis
    • Jonsson A, Borg A, Hannesson P, et al (1994) Film-screen vs. digital radiography in rheumatoid arthritis of the hand. An ROC analysis. Acta Radiol 35:311-318
    • (1994) Acta. Radiol. , vol.35 , pp. 311-318
    • Jonsson, A.1    Borg, A.2    Hannesson, P.3
  • 26
    • 0028331961 scopus 로고
    • Digital radiography in pediatric orthopaedics: A prospective, controlled, and randomized trial
    • Phillips JH, Albregts AE, Kling TF Jr, et al (1994) Digital radiography in pediatric orthopaedics: a prospective, controlled, and randomized trial. J Pediatr Orthop 14:377-380
    • (1994) J. Pediatr. Orthop. , vol.14 , pp. 377-380
    • Phillips, J.H.1    Albregts, A.E.2    Kling T.F., Jr.3
  • 27
    • 0027845524 scopus 로고
    • Comparative evaluation of digital radiography versus conventional radiography of fractured skulls
    • Langen HJ, Klein HM, Wein B, et al (1993) Comparative evaluation of digital radiography versus conventional radiography of fractured skulls. Invest Radiol 28:686-689
    • (1993) Invest. Radiol. , vol.28 , pp. 686-689
    • Langen, H.J.1    Klein, H.M.2    Wein, B.3
  • 28
    • 0035178468 scopus 로고    scopus 로고
    • Detection of porcine bone lesions and fissures: Comparing digital selenium, digital luminescence, and analog film-screen radiography
    • Zähringer M, Krug B, Kamm KF, et al (2001) Detection of porcine bone lesions and fissures: comparing digital selenium, digital luminescence, and analog film-screen radiography. AJR 177:1397-1403
    • (2001) AJR , vol.177 , pp. 1397-1403
    • Zähringer, M.1    Krug, B.2    Kamm, K.F.3
  • 29
    • 0035114759 scopus 로고    scopus 로고
    • Comparison of full-field digital mammography with screen-film mammography for cancer detection: Results of 4,945 paired examinations
    • Lewin JM, Hendrick RE, D'Orsi CJ, et al (2001) Comparison of full-field digital mammography with screen-film mammography for cancer detection: results of 4,945 paired examinations. Radiology 218:873-880
    • (2001) Radiology , vol.218 , pp. 873-880
    • Lewin, J.M.1    Hendrick, R.E.2    D'Orsi, C.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.