-
1
-
-
0032896881
-
Determination of Hounsfield value for CT-based design of custom femoral stems
-
Aamodt A, Kvistad KA, Andersen E, Lund-Larsen J, Eine J, Benum P, Husby OS (1999) Determination of Hounsfield value for CT-based design of custom femoral stems. J Bone Joint Surg Br 81: 143-147
-
(1999)
J. Bone Joint Surg. Br.
, vol.81
, pp. 143-147
-
-
Aamodt, A.1
Kvistad, K.A.2
Andersen, E.3
Lund-Larsen, J.4
Eine, J.5
Benum, P.6
Husby, O.S.7
-
2
-
-
0035100715
-
The internal calcar septum (femoral thigh spur) in computed tomography and conventional radiography
-
Adam F, Hammer D, Pape D, Kohn D (2001) The internal calcar septum (femoral thigh spur) in computed tomography and conventional radiography. Skeletal Radiol 30: 77-83
-
(2001)
Skeletal Radiol.
, vol.30
, pp. 77-83
-
-
Adam, F.1
Hammer, D.2
Pape, D.3
Kohn, D.4
-
3
-
-
0024957917
-
Shape the implant to the patient. A rationale for the use of custom-fit cementless total hip implants
-
Bargar WL (1989) Shape the implant to the patient. A rationale for the use of custom-fit cementless total hip implants. Clin Orthop 249: 73-78
-
(1989)
Clin. Orthop.
, vol.249
, pp. 73-78
-
-
Bargar, W.L.1
-
4
-
-
0018859794
-
Mechanical property distributions in the cancellous bone of the human proximal femur
-
Brown TD, Ferguson AB Jr (1980) Mechanical property distributions in the cancellous bone of the human proximal femur. Acta Orthop Scand 51: 429-437
-
(1980)
Acta Orthop. Scand.
, vol.51
, pp. 429-437
-
-
Brown, T.D.1
Ferguson A.B., Jr.2
-
5
-
-
0024951130
-
Fit the patient to the prosthesis. An argument against the routine use of custom hip implants
-
Capello WN (1989) Fit the patient to the prosthesis. An argument against the routine use of custom hip implants. Clin Orthop 249: 56-59
-
(1989)
Clin. Orthop.
, vol.249
, pp. 56-59
-
-
Capello, W.N.1
-
6
-
-
0026674164
-
Computerized templating in uncemented total hip arthroplasty to assess component fit and fill
-
Clarke HJ, Jinnah RH, Cox QG, Curtis MJ (1992) Computerized templating in uncemented total hip arthroplasty to assess component fit and fill. J Arthroplasty 7: 235-239
-
(1992)
J. Arthroplasty
, vol.7
, pp. 235-239
-
-
Clarke, H.J.1
Jinnah, R.H.2
Cox, Q.G.3
Curtis, M.J.4
-
7
-
-
0001560122
-
Geometric and biomechanical analysis of the human femur
-
Dai KR, An KN, Hein Tjea (1985) Geometric and biomechanical analysis of the human femur. Orthop Trans 10: 256-261
-
(1985)
Orthop. Trans.
, vol.10
, pp. 256-261
-
-
Dai, K.R.1
An, K.N.2
Hein, T.3
-
8
-
-
0032781830
-
Measurement of thickness and density of thin structures by computed tomography: A simulation study
-
Dougherty G, Newman D (1999) Measurement of thickness and density of thin structures by computed tomography: a simulation study. Med Phys 26: 1341-1348
-
(1999)
Med. Phys.
, vol.26
, pp. 1341-1348
-
-
Dougherty, G.1
Newman, D.2
-
9
-
-
0029130131
-
Three-dimensional anatomy of the cancellous structures within the proximal femur from computed tomography data
-
Elke RP, Cheal EJ, Simmons C, Poss R (1995) Three-dimensional anatomy of the cancellous structures within the proximal femur from computed tomography data. J Orthop Res 13: 513-523
-
(1995)
J. Orthop. Res.
, vol.13
, pp. 513-523
-
-
Elke, R.P.1
Cheal, E.J.2
Simmons, C.3
Poss, R.4
-
10
-
-
0026531266
-
Fit and fill: Fashionable fact or fantasy?
-
Horne G (1992) Fit and fill: fashionable fact or fantasy? J Bone Joint Surg Br 74: 4-5
-
(1992)
J. Bone Joint Surg. Br.
, vol.74
, pp. 4-5
-
-
Horne, G.1
-
11
-
-
0030002439
-
Accuracy of using radiographs for custom hip stem design
-
Iguchi H, Hua J, Walker PS (1996) Accuracy of using radiographs for custom hip stem design. J Arthroplasty 11: 312-321
-
(1996)
J. Arthroplasty
, vol.11
, pp. 312-321
-
-
Iguchi, H.1
Hua, J.2
Walker, P.S.3
-
12
-
-
0031002597
-
Image processing for femoral endosteal anatomy detection: Description and testing of a computed tomography based program
-
Laine HJ, Kontola K, Lehto MU, Pitkanen M, Jarske P, Lindholm TS (1997) Image processing for femoral endosteal anatomy detection: description and testing of a computed tomography based program. Phys Med Biol 42: 1673-1689
-
(1997)
Phys. Med. Biol.
, vol.42
, pp. 1673-1689
-
-
Laine, H.J.1
Kontola, K.2
Lehto, M.U.3
Pitkanen, M.4
Jarske, P.5
Lindholm, T.S.6
-
14
-
-
0030717503
-
Tapered design for the cementless total hip arthroplasty femoral component
-
Mallory TH, Head WC, Lombardi AV (1997) Tapered design for the cementless total hip arthroplasty femoral component. Clin Orthop 344: 172-178
-
(1997)
Clin. Orthop.
, vol.344
, pp. 172-178
-
-
Mallory, T.H.1
Head, W.C.2
Lombardi, A.V.3
-
15
-
-
0000377936
-
Bemerkungen über das Os femoris
-
Merkel FR (1874) Bemerkungen über das Os femoris. Arch Pathol Anat 59: 237-241
-
(1874)
Arch. Pathol. Anat.
, vol.59
, pp. 237-241
-
-
Merkel, F.R.1
-
16
-
-
0023789202
-
The anatomic basis of femoral component design
-
Noble PC, Alexander JW, Lindahl LJ, Yew DT, Granberry WM, Tullos HS (1988) The anatomic basis of femoral component design. Clin Orthop 235: 148-165
-
(1988)
Clin. Orthop.
, vol.235
, pp. 148-165
-
-
Noble, P.C.1
Alexander, J.W.2
Lindahl, L.J.3
Yew, D.T.4
Granberry, W.M.5
Tullos, H.S.6
-
17
-
-
0029146236
-
The effect of aging on the shape of the proximal femur
-
Noble PC, Box GG, Kamaric E, Fink MJ, Alexander JW, Tullos HS (1995) The effect of aging on the shape of the proximal femur. Clin Orthop 316: 31-44
-
(1995)
Clin. Orthop.
, vol.316
, pp. 31-44
-
-
Noble, P.C.1
Box, G.G.2
Kamaric, E.3
Fink, M.J.4
Alexander, J.W.5
Tullos, H.S.6
-
18
-
-
0023907919
-
Improving the fit of press-fit hip stems
-
Robertson DD (1988) Improving the fit of press-fit hip stems. Clin Orthop 228: 134-140
-
(1988)
Clin. Orthop.
, vol.228
, pp. 134-140
-
-
Robertson, D.D.1
-
19
-
-
0023227991
-
Design of custom hip stem prostheses using three-dimensional CT modeling
-
Robertson DD, Walker PS, Granholm JW, Nelson PC, Weiss PJ, Fishman EK, Magid D (1987) Design of custom hip stem prostheses using three-dimensional CT modeling. J Comput Assist Tomogr 5: 804-809
-
(1987)
J. Comput. Assist. Tomogr.
, vol.5
, pp. 804-809
-
-
Robertson, D.D.1
Walker, P.S.2
Granholm, J.W.3
Nelson, P.C.4
Weiss, P.J.5
Fishman, E.K.6
Magid, D.7
-
20
-
-
0026599455
-
The morphology of the proximal femur. A three-dimensional radiographic analysis
-
Rubin PJ, Leyvraz PF, Aubaniac JM, Argenson JN, Esteve P, De Roguin B (1992) The morphology of the proximal femur. A three-dimensional radiographic analysis. J Bone Joint Surg Br 74: 28-32
-
(1992)
J. Bone Joint Surg. Br.
, vol.74
, pp. 28-32
-
-
Rubin, P.J.1
Leyvraz, P.F.2
Aubaniac, J.M.3
Argenson, J.N.4
Esteve, P.5
De Roguin, B.6
-
21
-
-
0019978336
-
Measurement of cortical thickness in a human cadaver femur. Conventional roentgenography versus computed tomography
-
Smith HW, De Smet AA, Levine E (1982) Measurement of cortical thickness in a human cadaver femur. Conventional roentgenography versus computed tomography. Clin Orthop 169: 269-274
-
(1982)
Clin. Orthop.
, vol.169
, pp. 269-274
-
-
Smith, H.W.1
De Smet, A.A.2
Levine, E.3
-
22
-
-
0032456049
-
Computed-tomography-based computer preoperative planning for total hip arthroplasty
-
Sugano N, Ohzono K, Nishii T, Haraguchi K, Sakai T, Ochi T (1998) Computed-tomography-based computer preoperative planning for total hip arthroplasty. Comput Aided Surg 3: 320-324
-
(1998)
Comput. Aided Surg.
, vol.3
, pp. 320-324
-
-
Sugano, N.1
Ohzono, K.2
Nishii, T.3
Haraguchi, K.4
Sakai, T.5
Ochi, T.6
-
23
-
-
0026602161
-
Torsional fixation of the femoral component in total hip arthroplasty. The effect of surgical press-fit technique
-
Sugiyama H, Whiteside LA, Engh CA (1992) Torsional fixation of the femoral component in total hip arthroplasty. The effect of surgical press-fit technique. Clin Orthop 275: 187-193
-
(1992)
Clin. Orthop.
, vol.275
, pp. 187-193
-
-
Sugiyama, H.1
Whiteside, L.A.2
Engh, C.A.3
-
24
-
-
0023161998
-
Strains and micromotions of press-fit femoral stem prostheses
-
Walker PS (1987) Strains and micromotions of press-fit femoral stem prostheses. J Biomech 20: 693-702
-
(1987)
J. Biomech.
, vol.20
, pp. 693-702
-
-
Walker, P.S.1
-
25
-
-
0023759917
-
Design and fabrication of cementless hip stems
-
Walker PS (1988) Design and fabrication of cementless hip stems. Clin Orthop 235: 25-34
-
(1988)
Clin. Orthop.
, vol.235
, pp. 25-34
-
-
Walker, P.S.1
-
27
-
-
0023802491
-
Biologic fixation of a press-fit titanium hip joint endoprosthesis
-
Zweymüller KA, Lintner FK, Semlitsch MF (1988) Biologic fixation of a press-fit titanium hip joint endoprosthesis. Clin Orthop 235: 195-206
-
(1988)
Clin. Orthop.
, vol.235
, pp. 195-206
-
-
Zweymüller, K.A.1
Lintner, F.K.2
Semlitsch, M.F.3
|