메뉴 건너뛰기




Volumn 31, Issue 8, 2002, Pages 445-450

In vivo high-resolution MR imaging of the carpal tunnel at 8.0 tesla

Author keywords

Cartilage; High resolution MR imaging; High field MRI; Magnetic resonance imaging; Tendon; Wrist

Indexed keywords

ARTICLE; BLOOD VESSEL; BODY POSTURE; CARPAL TUNNEL SYNDROME; CONTRAST ENHANCEMENT; CONTROLLED STUDY; FEASIBILITY STUDY; FLEXOR TENDON; HUMAN; HUMAN EXPERIMENT; IN VIVO STUDY; INTERMETHOD COMPARISON; MEDIAN NERVE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SOFT TISSUE;

EID: 0036934894     PISSN: 03642348     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00256-002-0506-z     Document Type: Article
Times cited : (27)

References (32)
  • 1
    • 0028880506 scopus 로고
    • Carpal tunnel syndrome: Correlation of magnetic resonance imaging, clinical, electrodiagnostic, and intraoperative findings
    • Britz GW, Haynor DR, Kuntz C, Goodkin R, Gitter, A, Kliot M. Carpal tunnel syndrome: correlation of magnetic resonance imaging, clinical, electrodiagnostic, and intraoperative findings. Neurosurgery 1995; 37:1097-1103.
    • (1995) Neurosurgery , vol.37 , pp. 1097-1103
    • Britz, G.W.1    Haynor, D.R.2    Kuntz, C.3    Goodkin, R.4    Gitter, A.5    Kliot, M.6
  • 2
    • 0012382974 scopus 로고
    • Diagnosis of nerve injury
    • Mackinnen SE, Dellon AL, eds. New York: Thieme
    • McKinnen SE, Dellon AL. Diagnosis of nerve injury. In: Mackinnen SE, Dellon AL, eds. Surgery of the peripheral nerve. New York: Thieme, 1988:74-79.
    • (1988) Surgery of the Peripheral Nerve , pp. 74-79
    • McKinnen, S.E.1    Dellon, A.L.2
  • 3
    • 0012424908 scopus 로고
    • Carpal tunnel and ulnar tunnel syndromes and stenosing tenosynovitis
    • Crenshaw AH, ed. 8th ed. St Louis: Mosby
    • Wright PE. Carpal tunnel and ulnar tunnel syndromes and stenosing tenosynovitis. In: Crenshaw AH, ed. Campbell's operative orthopaedics. 8th ed. St Louis: Mosby, 1992:3435-3437.
    • (1992) Campbell's Operative Orthopaedics , pp. 3435-3437
    • Wright, P.E.1
  • 7
    • 0023125856 scopus 로고
    • MR imaging of the carpal tunnel: Normal anatomy and preliminary findings in the carpal tunnel syndrome
    • Middleton WD, Kneeland JB, Kellman GM, et al. MR imaging of the carpal tunnel: normal anatomy and preliminary findings in the carpal tunnel syndrome. AJR Am J Roentgenol 1987; 148:307-316.
    • (1987) AJR Am. J. Roentgenol. , vol.148 , pp. 307-316
    • Middleton, W.D.1    Kneeland, J.B.2    Kellman, G.M.3
  • 9
    • 0031303007 scopus 로고    scopus 로고
    • Carpal tunnel syndrome: Are the MR findings a result of population selection bias?
    • Radack DM, Schweitzer ME, Taras J. Carpal tunnel syndrome: are the MR findings a result of population selection bias? AJR Am J Roentgenol 1997; 169:1649-1653.
    • (1997) AJR Am. J. Roentgenol. , vol.169 , pp. 1649-1653
    • Radack, D.M.1    Schweitzer, M.E.2    Taras, J.3
  • 11
    • 0029914365 scopus 로고    scopus 로고
    • Anatomic delineation of the ulnar nerve and ulnar artery in relation to the carpal tunnel by axial magnetic resonance imaging
    • Netscher D, Polsen C, Thornby J, Choi H, Udeh J. Anatomic delineation of the ulnar nerve and ulnar artery in relation to the carpal tunnel by axial magnetic resonance imaging. J Hand Surg [Am] 1996; 21:273-276.
    • (1996) J. Hand Surg. [Am] , vol.21 , pp. 273-276
    • Netscher, D.1    Polsen, C.2    Thornby, J.3    Choi, H.4    Udeh, J.5
  • 19
    • 0032724834 scopus 로고    scopus 로고
    • Black body and transverse electromagnetic resonators operating at 340 MHz: Volume RF coils for ultra high field MRI
    • Robitaille PML. Black body and transverse electromagnetic resonators operating at 340 MHz: volume RF coils for ultra high field MRI. J Comput Assist Tomogr 1999; 23:879-890.
    • (1999) J. Comput. Assist. Tomogr. , vol.23 , pp. 879-890
    • Robitaille, P.M.L.1
  • 21
    • 0033630179 scopus 로고    scopus 로고
    • High resolution MR imaging of the carpal tunnel and the wrist: Application of a 5-cm surface coil
    • Maurer J, Bleschkowski A, Tempka A, Felix R. High resolution MR imaging of the carpal tunnel and the wrist: application of a 5-cm surface coil. Acta Radiol 2000; 41:78-83.
    • (2000) Acta Radiol. , vol.41 , pp. 78-83
    • Maurer, J.1    Bleschkowski, A.2    Tempka, A.3    Felix, R.4
  • 23
    • 0024315867 scopus 로고
    • Anatomic relations between the median nerve and flexor tendons in the carpal tunnel: MR evaluation in normal volunteers
    • Zeiss J, Skie M, Ebraheim N, Jackson WT. Anatomic relations between the median nerve and flexor tendons in the carpal tunnel: MR evaluation in normal volunteers. AJR Am J Roentgenol 1989; 153:533-536.
    • (1989) AJR Am. J. Roentgenol. , vol.153 , pp. 533-536
    • Zeiss, J.1    Skie, M.2    Ebraheim, N.3    Jackson, W.T.4
  • 24
    • 0023888406 scopus 로고
    • Reactive perineural fibroblastic proliferation of the median nerve: MR characteristics
    • Bodne D, Quinn SF, Kloss J, et al, Reactive perineural fibroblastic proliferation of the median nerve: MR characteristics. J Comput Assist Tomogr 1988; 12:532-534.
    • (1988) J. Comput. Assist. Tomogr. , vol.12 , pp. 532-534
    • Bodne, D.1    Quinn, S.F.2    Kloss, J.3
  • 25
    • 0029125738 scopus 로고
    • MRI of peripheral nerves and pathology of sural nerves in hereditary motor and sensory neuropathy type III
    • Tachi T, Kozka N, Ohya K, Chiba S, Naganuma M. MRI of peripheral nerves and pathology of sural nerves in hereditary motor and sensory neuropathy type III. Neuroradiology 1995; 37:496-499.
    • (1995) Neuroradiology , vol.37 , pp. 496-499
    • Tachi, T.1    Kozka, N.2    Ohya, K.3    Chiba, S.4    Naganuma, M.5
  • 26
    • 9344236516 scopus 로고    scopus 로고
    • Application of magnetic resonance neurography in the evaluation of patients with peripheral nerve pathology
    • Filler AG, Kliot M, Howe FA, et al. Application of magnetic resonance neurography in the evaluation of patients with peripheral nerve pathology. J Neurosurg 1996; 85:299-309.
    • (1996) J. Neurosurg. , vol.85 , pp. 299-309
    • Filler, A.G.1    Kliot, M.2    Howe, F.A.3
  • 27
    • 0004281917 scopus 로고
    • 28th ed. Philadelphia: Lea & Febiger
    • Goss CM, ed. Gray's anatomy. 28th ed. Philadelphia: Lea & Febiger, 1966:975.
    • (1966) Gray's Anatomy , pp. 975
    • Goss, C.M.1
  • 28
    • 0030666614 scopus 로고    scopus 로고
    • High resolution imaging of the musculoskeletal system
    • Erickson SE. High resolution imaging of the musculoskeletal system. Radiology 1997; 205:593-618.
    • (1997) Radiology , vol.205 , pp. 593-618
    • Erickson, S.E.1
  • 29
    • 0029782266 scopus 로고    scopus 로고
    • Changes in water diffusion due to wallerian degeneration in peripheral nerve
    • Beaulieu C, Does MD, Snyder RE, Allen PS. Changes in water diffusion due to wallerian degeneration in peripheral nerve. Magn Reson Med 1996; 36:627-631.
    • (1996) Magn. Reson. Med. , vol.36 , pp. 627-631
    • Beaulieu, C.1    Does, M.D.2    Snyder, R.E.3    Allen, P.S.4
  • 30
    • 0028048621 scopus 로고
    • Diagnosis of compressive and entrapment neuropathy of the upper extremity: Value of MR imaging
    • Beltran J, Rosenberg ZS. Diagnosis of compressive and entrapment neuropathy of the upper extremity: value of MR imaging. AJR Am J Roentgenol 1994; 163:525-531.
    • (1994) AJR Am. J. Roentgenol. , vol.163 , pp. 525-531
    • Beltran, J.1    Rosenberg, Z.S.2
  • 32
    • 0032914675 scopus 로고    scopus 로고
    • NMR relaxation times in the human brain at 3.0 tesla
    • Wanaspura, JP, Holland SK, Dunn RS, Ball WS. NMR relaxation times in the human brain at 3.0 tesla. J MRI 1999; 9:531-538.
    • (1999) J MRI , vol.9 , pp. 531-538
    • Wanaspura, J.P.1    Holland, S.K.2    Dunn, R.S.3    Ball, W.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.