메뉴 건너뛰기




Volumn 25, Issue 12, 2002, Pages 1715-1723

Upgrade of permanent pacemakers and single chamber implantable cardioverter defibrillators to pectoral dual chamber implantable cardioverter defibrillators: Indications, surgical approach, and long-term clinical results

Author keywords

LCDs; Pacemaker; Surgery

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; CLINICAL FEATURE; CONTROLLED STUDY; DEFIBRILLATOR; ELECTRIC CONDUCTIVITY; ELECTRIC POTENTIAL; FEMALE; FOLLOW UP; HEART EJECTION FRACTION; HUMAN; ISCHEMIC HEART DISEASE; LONG QT SYNDROME; MAJOR CLINICAL STUDY; MALE; SURGICAL TECHNIQUE; TREATMENT INDICATION; TREATMENT OUTCOME;

EID: 0036915687     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1460-9592.2002.01715.x     Document Type: Article
Times cited : (16)

References (47)
  • 2
    • 0028077584 scopus 로고
    • Feasibility of concomitant implantation of permanent transvenous pacemaker and defibrillator systems
    • Blanck Z, Niazi I, Axtell K, et al. Feasibility of concomitant implantation of permanent transvenous pacemaker and defibrillator systems. Am J Cardiol 1994; 74:1249-1253.
    • (1994) Am J Cardiol , vol.74 , pp. 1249-1253
    • Blanck, Z.1    Niazi, I.2    Axtell, K.3
  • 3
    • 0028817526 scopus 로고
    • Implantation of transvenous nonthoracotomy cardioverter-defibrillator systems in patients with permanent endocardial pacemakers
    • Brooks R, Garan H, McGovern BA, et al. Implantation of transvenous nonthoracotomy cardioverter-defibrillator systems in patients with permanent endocardial pacemakers. Am Heart J 1995; 129:45-53.
    • (1995) Am Heart J , vol.129 , pp. 45-53
    • Brooks, R.1    Garan, H.2    McGovern, B.A.3
  • 4
    • 17344378906 scopus 로고    scopus 로고
    • Physiologic cardiac pacing in patients with contemporary implantable cardioverter-defibrillators
    • Iskos D, Fahy GJ, Lurie KG, et al. Physiologic cardiac pacing in patients with contemporary implantable cardioverter-defibrillators. Am J Cardiol 1998; 82:66-71.
    • (1998) Am J Cardiol , vol.82 , pp. 66-71
    • Iskos, D.1    Fahy, G.J.2    Lurie, K.G.3
  • 5
    • 8044261416 scopus 로고    scopus 로고
    • Interactions between transvenous nonthoracotomy cardioverter defibrillator systems and permanent transvenous endocardial pacemakers
    • Geiger MJ, O'Neill P, Sharma A, et al. Interactions between transvenous nonthoracotomy cardioverter defibrillator systems and permanent transvenous endocardial pacemakers. PACE 1997; 20:624-630.
    • (1997) PACE , vol.20 , pp. 624-630
    • Geiger, M.J.1    O'Neill, P.2    Sharma, A.3
  • 6
    • 0031958610 scopus 로고    scopus 로고
    • Importance of pacemaker noise reversion as a potential mechanism of pacemaker-ICD interactions
    • Glikson M, Trusty JM, Grice SK, et al. Importance of pacemaker noise reversion as a potential mechanism of pacemaker-ICD interactions. PACE 1998; 21:1111-1121.
    • (1998) PACE , vol.21 , pp. 1111-1121
    • Glikson, M.1    Trusty, J.M.2    Grice, S.K.3
  • 7
    • 0002994003 scopus 로고    scopus 로고
    • Implanation of ICDs in the electrophysiology laboratory
    • I Singer, (ed.). Baltimore, Williams and Wilkins
    • Jones GK, Bardy GH. Implanation of ICDs in the electrophysiology laboratory. In I Singer, (ed.): Interventional Electrophysiology. Baltimore, Williams and Wilkins, 1997, pp. 725-740.
    • (1997) Interventional Electrophysiology , pp. 725-740
    • Jones, G.K.1    Bardy, G.H.2
  • 8
    • 0002830337 scopus 로고
    • Management of implant complications
    • KA Ellenbogen, GN K, BL Kay Wilkoff (eds.). Philadelphia, W.B. Saunders Company
    • Byrd CL. Management of implant complications. In KA Ellenbogen, GN K, BL Kay Wilkoff (eds.): Clinical Cardiac Pacing. Philadelphia, W.B. Saunders Company, 1995, pp. 491-522.
    • (1995) Clinical Cardiac Pacing , pp. 491-522
    • Byrd, C.L.1
  • 9
    • 0030887221 scopus 로고    scopus 로고
    • Effect of a passive endocardial electrode on defibrillation efficacy of a nonthoracotomy lead system
    • Fotuhi PC, KenKnight BH, Melnick SB, et al. Effect of a passive endocardial electrode on defibrillation efficacy of a nonthoracotomy lead system. J Am Coll Cardiol 1997; 29:825-830.
    • (1997) J Am Coll Cardiol , vol.29 , pp. 825-830
    • Fotuhi, P.C.1    KenKnight, B.H.2    Melnick, S.B.3
  • 10
    • 26344456842 scopus 로고    scopus 로고
    • Predictors of thrombosis after transvenous permanent pacemaker implantation
    • Jarwe M, Messaoudene SA, Klug D, et al. Predictors of thrombosis after transvenous permanent pacemaker implantation. (abstract) Circulation 2000; 102:II-787.
    • (2000) Circulation , vol.102
    • Jarwe, M.1    Messaoudene, S.A.2    Klug, D.3
  • 11
    • 0035035997 scopus 로고    scopus 로고
    • Prevalence of central venous occlusion in patients with chronic implantable defibrillator leads
    • Sticherling C, Chough SP, Baker RL, et al. Prevalence of central venous occlusion in patients with chronic implantable defibrillator leads. Am Heart J 2001: 141:813-816.
    • (2001) Am Heart J , vol.141 , pp. 813-816
    • Sticherling, C.1    Chough, S.P.2    Baker, R.L.3
  • 12
    • 0025614577 scopus 로고
    • Intravascular lead extraction using locking stylets and sheaths
    • Byrd CL, Schwartz SJ, Hedin NB, et al. Intravascular lead extraction using locking stylets and sheaths. PACE 1990; 13:1871-1875.
    • (1990) PACE , vol.13 , pp. 1871-1875
    • Byrd, C.L.1    Schwartz, S.J.2    Hedin, N.B.3
  • 13
    • 0033520022 scopus 로고    scopus 로고
    • Initial experience with larger laser sheaths for the removal of transvenous pacemaker and implantable defibrillator leads
    • Epstein LM, Byrd CL, Wilkoff BL, et al. Initial experience with larger laser sheaths for the removal of transvenous pacemaker and implantable defibrillator leads. Circulation 1999; 100:516-525.
    • (1999) Circulation , vol.100 , pp. 516-525
    • Epstein, L.M.1    Byrd, C.L.2    Wilkoff, B.L.3
  • 14
    • 0023270355 scopus 로고
    • Cephalic vein guide wire technique for implantation of permanent pacemakers
    • Ong LS, Barold SS, Lederman M, et al. Cephalic vein guide wire technique for implantation of permanent pacemakers. Am Heart J 1987; 114:753-756.
    • (1987) Am Heart J , vol.114 , pp. 753-756
    • Ong, L.S.1    Barold, S.S.2    Lederman, M.3
  • 15
    • 0027442941 scopus 로고
    • A new approach to percutaneous subclavian venipuncture to avoid lead fracture or central venous catheter occlusion
    • Magney JE, Staplin DH, Flynn DM, et al. A new approach to percutaneous subclavian venipuncture to avoid lead fracture or central venous catheter occlusion. PACE 1993; 16:2133-2142.
    • (1993) PACE , vol.16 , pp. 2133-2142
    • Magney, J.E.1    Staplin, D.H.2    Flynn, D.M.3
  • 16
    • 0027183654 scopus 로고
    • Standardized reporting of ICD patient outcome: The report of a North American Society of Pacing and Electrophysiology Policy Conference, February 9-10, 1993
    • Kim SG, Fogoros RN, Furman S, et al. Standardized reporting of ICD patient outcome: The report of a North American Society of Pacing and Electrophysiology Policy Conference, February 9-10, 1993. PACE 1993; 16:1358-1362.
    • (1993) PACE , vol.16 , pp. 1358-1362
    • Kim, S.G.1    Fogoros, R.N.2    Furman, S.3
  • 17
    • 0032721104 scopus 로고    scopus 로고
    • Outcome of patients with nonischemic dilated cardiomyopathy and unexplained syncope treated with an implantable defibrillator
    • Knight BP, Strickberger SA, Daoud E, et al. Outcome of patients with nonischemic dilated cardiomyopathy and unexplained syncope treated with an implantable defibrillator. J Am Coll Cardiol 1999; 33:1970-1974.
    • (1999) J Am Coll Cardiol , vol.33 , pp. 1970-1974
    • Knight, B.P.1    Strickberger, S.A.2    Daoud, E.3
  • 18
    • 0034628532 scopus 로고    scopus 로고
    • Efficacy of implantable cardioverter-defibrillators for the prevention of sudden death in patients with hypertrophic cardiomyopathy
    • Maron BJ, Shen WK, Link M, et al. Efficacy of implantable cardioverter-defibrillators for the prevention of sudden death in patients with hypertrophic cardiomyopathy. N Engl J Med 2000; 342:365-373.
    • (2000) N Engl J Med , vol.342 , pp. 365-373
    • Maron, B.J.1    Shen, W.K.2    Link, M.3
  • 20
    • 0034036119 scopus 로고    scopus 로고
    • A randomized trial comparing heparin initiation 6h or 24h after pacemaker or defibrillator implantation
    • Michaud G, Pelosi F Jr, Noble MD, et al. A randomized trial comparing heparin initiation 6h or 24h after pacemaker or defibrillator implantation. J Am Coll Cardiol 2000; 35:1915-1918.
    • (2000) J Am Coll Cardiol , vol.35 , pp. 1915-1918
    • Michaud, G.1    Pelosi F., Jr.2    Noble, M.D.3
  • 21
    • 0028864523 scopus 로고
    • Elevated defibrillation threshold when right-sided venous access is used for nonthoracotomy implantable defibrillator lead implantation. The Endotak Investigators
    • Epstein AE, Kay GN, Plumb VJ, et al. Elevated defibrillation threshold when right-sided venous access is used for nonthoracotomy implantable defibrillator lead implantation. The Endotak Investigators. J Cardiovasc Electrophysiol 1995; 6:979-986.
    • (1995) J Cardiovasc Electrophysiol , vol.6 , pp. 979-986
    • Epstein, A.E.1    Kay, G.N.2    Plumb, V.J.3
  • 22
    • 0012138244 scopus 로고    scopus 로고
    • Right sided active pectoral pulse generators do not reduce defibrillation thresholds
    • Kirk MM, Shorofsky SR, Gold MR. Right sided active pectoral pulse generators do not reduce defibrillation thresholds. (abstract) PACE 1999; 22:747.
    • (1999) PACE , vol.22 , pp. 747
    • Kirk, M.M.1    Shorofsky, S.R.2    Gold, M.R.3
  • 23
    • 0028861895 scopus 로고
    • Influence of epicardial patches on defibrillafion threshold with nonthoracotomy lead configurations
    • Fotuhi PC, Ideker RE, Idriss SF, et al. Influence of epicardial patches on defibrillafion threshold with nonthoracotomy lead configurations. Circulation 1995; 92:3082-3088.
    • (1995) Circulation , vol.92 , pp. 3082-3088
    • Fotuhi, P.C.1    Ideker, R.E.2    Idriss, S.F.3
  • 24
    • 0028924520 scopus 로고
    • Comparison of defibrillation probability of success curves for an endocardial lead configuration with and without an inactive epicardial patch
    • Callihan RL, Idriss SF, Dahl RW, et al. Comparison of defibrillation probability of success curves for an endocardial lead configuration with and without an inactive epicardial patch. J Am Coll Cardiol 1995; 25:1373-1379.
    • (1995) J Am Coll Cardiol , vol.25 , pp. 1373-1379
    • Callihan, R.L.1    Idriss, S.F.2    Dahl, R.W.3
  • 25
    • 0035043891 scopus 로고    scopus 로고
    • Provoked and spontaneous high frequency, low amplitude respirophasic noise transients in patients with implantable cardioverter-defibrillators
    • Sweeney MO, Ellison KE, Shea JB. Provoked and spontaneous high frequency, low amplitude respirophasic noise transients in patients with implantable cardioverter-defibrillators. J Cardiovasc Electrophysiol 2001; 12:402-410.
    • (2001) J Cardiovasc Electrophysiol , vol.12 , pp. 402-410
    • Sweeney, M.O.1    Ellison, K.E.2    Shea, J.B.3
  • 26
    • 0000187305 scopus 로고    scopus 로고
    • Atrial lead position affects far-field R wave oversensing for rate responsive dual chamber implantable cardioverter defibrillators
    • Williamson B, Baker JH, Bartelt NJ, et al. Atrial lead position affects far-field R wave oversensing for rate responsive dual chamber implantable cardioverter defibrillators. (abstract) PACE 1999; 22:849.
    • (1999) PACE , vol.22 , pp. 849
    • Williamson, B.1    Baker, J.H.2    Bartelt, N.J.3
  • 27
    • 0032710593 scopus 로고    scopus 로고
    • Bipolar ventricular far-field signals in the atrium
    • Frohlig G, Iewani Z, Kusch O, et al. Bipolar ventricular far-field signals in the atrium. PACE 1999; 22:1604-1613.
    • (1999) PACE , vol.22 , pp. 1604-1613
    • Frohlig, G.1    Iewani, Z.2    Kusch, O.3
  • 28
    • 0000947113 scopus 로고    scopus 로고
    • Mode switch without atrial tachyarrhythmias
    • Frohlig G, Kinderman M, Heisel A, et al. Mode switch without atrial tachyarrhythmias. (abstract) PACE 1996; 19:592.
    • (1996) PACE , vol.19 , pp. 592
    • Frohlig, G.1    Kinderman, M.2    Heisel, A.3
  • 29
    • 0033081491 scopus 로고    scopus 로고
    • A stepwise testing protocol for modern implantable cardioverter defibrillator systems to prevent pacemaker-implantable cardioverter-defibrillator interactions
    • Glikson M, Trusty JM, Grice SK, et al. A stepwise testing protocol for modern implantable cardioverter defibrillator systems to prevent pacemaker-implantable cardioverter-defibrillator interactions. Am J Cardiol 1999; 83:360-366.
    • (1999) Am J Cardiol , vol.83 , pp. 360-366
    • Glikson, M.1    Trusty, J.M.2    Grice, S.K.3
  • 30
    • 0019120477 scopus 로고
    • Unusual complications of endocardial pacing
    • Lee ME, Chaux A. Unusual complications of endocardial pacing. J Thorac Cardiovasc Surg 1980; 80:934-940.
    • (1980) J Thorac Cardiovasc Surg , vol.80 , pp. 934-940
    • Lee, M.E.1    Chaux, A.2
  • 31
    • 0023736984 scopus 로고
    • Far-field QRS complex sensing via the atrial pacemaker lead. I. Mechanism, consequences, differential diagnosis and countermeasures in AAI and VDD/DDD pacing
    • Brandt J, Fahraeus T, Schuller H. Far-field QRS complex sensing via the atrial pacemaker lead. I. Mechanism, consequences, differential diagnosis and countermeasures in AAI and VDD/DDD pacing. PACE 1988; 11:1432-1438.
    • (1988) PACE , vol.11 , pp. 1432-1438
    • Brandt, J.1    Fahraeus, T.2    Schuller, H.3
  • 32
    • 0024274730 scopus 로고
    • Far-field QRS complex sensing via the atrial pacemaker lead. II. Prevalence, clinical significance and possibility of intraoperative prediction in DDD pacing
    • Brandt J, Fahraeus T, Schuller H. Far-field QRS complex sensing via the atrial pacemaker lead. II. Prevalence, clinical significance and possibility of intraoperative prediction in DDD pacing. PACE 1988; 11:1540-1544.
    • (1988) PACE , vol.11 , pp. 1540-1544
    • Brandt, J.1    Fahraeus, T.2    Schuller, H.3
  • 33
    • 0034021440 scopus 로고    scopus 로고
    • Far-field QRS complex sensing: Prevalence and timing with bipolar atrial leads
    • Brandt J, Worzewski W. Far-field QRS complex sensing: Prevalence and timing with bipolar atrial leads. PACE 2000; 23:315-320.
    • (2000) PACE , vol.23 , pp. 315-320
    • Brandt, J.1    Worzewski, W.2
  • 34
    • 0002604945 scopus 로고    scopus 로고
    • Far-field R wave oversensing in new dual chamber ICDs. Incidence, predisposing factors and clinical implications
    • Weretka S, Becker R, Hilbel T, et al. Far-field R wave oversensing in new dual chamber ICDs. Incidence, predisposing factors and clinical implications. (abstract) PACE 2000; 23:571.
    • (2000) PACE , vol.23 , pp. 571
    • Weretka, S.1    Becker, R.2    Hilbel, T.3
  • 35
    • 0021186817 scopus 로고
    • The effect of electrode position on atrial sensing for physiologically responsive cardiac pacemakers
    • Timmis GC, Westveer DC, Gadowski G, et al. The effect of electrode position on atrial sensing for physiologically responsive cardiac pacemakers. PACE 1984; 108:909-916.
    • (1984) PACE , vol.108 , pp. 909-916
    • Timmis, G.C.1    Westveer, D.C.2    Gadowski, G.3
  • 36
    • 0001561110 scopus 로고    scopus 로고
    • Effect of different location of the atrial lead on the nearfield and farfield electrograms in dual chamber pacemaker-defibrillators
    • Kantharia B, wilbur S, Padder F, et al. Effect of different location of the atrial lead on the nearfield and farfield electrograms in dual chamber pacemaker-defibrillators. (abstract) PACE 1999; 22:824.
    • (1999) PACE , vol.22 , pp. 824
    • Kantharia, B.1    Wilbur, S.2    Padder, F.3
  • 37
    • 0017706910 scopus 로고
    • A comparison of unipolar and bipolar electrograms for cardiac pacemaker sensing
    • DeCaprio V, Hurzeler P, Furman S. A comparison of unipolar and bipolar electrograms for cardiac pacemaker sensing. Circulation 1977; 56:750-755.
    • (1977) Circulation , vol.56 , pp. 750-755
    • DeCaprio, V.1    Hurzeler, P.2    Furman, S.3
  • 38
    • 0012202324 scopus 로고    scopus 로고
    • Importance of far field R wave sensing evaluation for correct function of arrhythmia discrimination algorithm in dual chamber ICD
    • Dijkman B, Wellens HJJ. Importance of far field R wave sensing evaluation for correct function of arrhythmia discrimination algorithm in dual chamber ICD. (abstract) PACE 2000; 23:676.
    • (2000) PACE , vol.23 , pp. 676
    • Dijkman, B.1    Wellens, H.J.J.2
  • 39
    • 0033163081 scopus 로고    scopus 로고
    • Inappropriate implantable defibrillator discharge caused by a retained pacemaker lead fragment
    • Lickfett L, Wolpert L, Jung W, et al. Inappropriate implantable defibrillator discharge caused by a retained pacemaker lead fragment. J Interv Card Electrophysiol 1999; 3:163-167.
    • (1999) J Interv Card Electrophysiol , vol.3 , pp. 163-167
    • Lickfett, L.1    Wolpert, L.2    Jung, W.3
  • 41
    • 0031030345 scopus 로고    scopus 로고
    • The value of DDD pacing in patients with an implantable cardioverter defibrillator
    • Geelen P, Lorga-Filho A, Chauvin M, et al. The value of DDD pacing in patients with an implantable cardioverter defibrillator. PACE 1997; 20:177-181.
    • (1997) PACE , vol.20 , pp. 177-181
    • Geelen, P.1    Lorga-Filho, A.2    Chauvin, M.3
  • 42
    • 0032104051 scopus 로고    scopus 로고
    • Indications for implantation of a dual-chamber pacemaker combined with an implantable cardioverter-defibrillator
    • Higgins SL, Williams SK, Pak JP, et al. Indications for implantation of a dual-chamber pacemaker combined with an implantable cardioverter-defibrillator. Am J Cardiol 1998; 81:1360-1362.
    • (1998) Am J Cardiol , vol.81 , pp. 1360-1362
    • Higgins, S.L.1    Williams, S.K.2    Pak, J.P.3
  • 43
    • 0000858283 scopus 로고    scopus 로고
    • Should all patients receive a dual chamber device? Unanticipated use of the implantable defibrillator as a pacemaker
    • Sutandar A, Solimon S, Kaddaha R, et al. Should all patients receive a dual chamber device? Unanticipated use of the implantable defibrillator as a pacemaker. J Am Coll Cardiol 2000; 35:127A.
    • (2000) J Am Coll Cardiol , vol.35
    • Sutandar, A.1    Solimon, S.2    Kaddaha, R.3
  • 44
    • 0031586473 scopus 로고    scopus 로고
    • Long-term follow-up of patients from a randomized trial of atrial versus ventricular pacing for sick-sinus syndrome
    • Andersen HR, Nielsen JC, Rhomsen PEB, et al. Long-term follow-up of patients from a randomized trial of atrial versus ventricular pacing for sick-sinus syndrome. Lancet 1997; 350:1210-1216.
    • (1997) Lancet , vol.350 , pp. 1210-1216
    • Andersen, H.R.1    Nielsen, J.C.2    Rhomsen, P.E.B.3
  • 45
    • 17544391516 scopus 로고    scopus 로고
    • For the Canadian Trial of Physiologic Pacing Investigators. Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes
    • Connolly SJ, Kerr CR, Gent M, et al., For the Canadian Trial of Physiologic Pacing Investigators. Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes. N Engl J Med 2000; 342:1385-1391.
    • (2000) N Engl J Med , vol.342 , pp. 1385-1391
    • Connolly, S.J.1    Kerr, C.R.2    Gent, M.3
  • 46
    • 0026448128 scopus 로고
    • Electrocardiographically documented unnecessary, spontaneous shocks in 241 patients with implantable cardioverter defibrillators
    • Grimm W, Flores BT, Marchlinski FE. Electrocardiographically documented unnecessary, spontaneous shocks in 241 patients with implantable cardioverter defibrillators. PACE 1992; 15:1667-1673.
    • (1992) PACE , vol.15 , pp. 1667-1673
    • Grimm, W.1    Flores, B.T.2    Marchlinski, F.E.3
  • 47
    • 0032990250 scopus 로고    scopus 로고
    • Clinical experience with the new detection algorithms for atrial fibrillation of a defibrillator with dual chamber sensing and pacing
    • Kuhlkamp V, Dornberger V, Mewis C, et al. Clinical experience with the new detection algorithms for atrial fibrillation of a defibrillator with dual chamber sensing and pacing. J Cardiovasc Electrophysiol 1999; 10:905-915.
    • (1999) J Cardiovasc Electrophysiol , vol.10 , pp. 905-915
    • Kuhlkamp, V.1    Dornberger, V.2    Mewis, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.