메뉴 건너뛰기




Volumn 26, Issue 10, 2002, Pages 851-855

The medtronic intact bioprosthesis: Clinical and hemodynamic performance over 13 years

Author keywords

Aortic Valve; Bioprosthesis; Medtronic Intact; Replacement

Indexed keywords

BLOOD VESSELS;

EID: 0036906741     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1525-1594.2002.06984.x     Document Type: Article
Times cited : (4)

References (20)
  • 1
    • 0026873268 scopus 로고
    • Prosthetic heart valve performance: Long term follow-up
    • O'Rourke RA, McCall D, eds. St. Louis: Mosby Year-Book
    • Grunkemeier GL, Starr A, Rahimtoola SH. Prosthetic heart valve performance: Long term follow-up. In: O'Rourke RA, McCall D, eds. Current Problems in Cardiology. St. Louis: Mosby Year-Book, 1992:329-406.
    • (1992) Current Problems in Cardiology , pp. 329-406
    • Grunkemeier, G.L.1    Starr, A.2    Rahimtoola, S.H.3
  • 4
    • 0026356431 scopus 로고
    • The zero pressure fixed Medtronic Intact porcine valve: Clinical results over six year period, including serial echocardiographic assessment
    • Barratt-Boyes BG, Ko PH, Jaffe WM. The zero pressure fixed Medtronic Intact porcine valve: Clinical results over six year period, including serial echocardiographic assessment. J Cardiac Surg 1991;6(Suppl 4):606-12.
    • (1991) J Cardiac Surg , vol.6 , pp. 606-612
    • Barratt-Boyes, B.G.1    Ko, P.H.2    Jaffe, W.M.3
  • 5
    • 0026465943 scopus 로고
    • Clinical experience with the zero-pressure fixed Medtronic Intact bioprosthetic valve
    • Barratt-Boyes BG. Clinical experience with the zero-pressure fixed Medtronic Intact bioprosthetic valve. Eur J Cardiothorac Surg 1992;6(Suppl I):S79-81.
    • (1992) Eur J Cardiothorac Surg , vol.6 , pp. S79-S81
    • Barratt-Boyes, B.G.1
  • 8
    • 0027959891 scopus 로고
    • Early clinical and hemodynamic evaluation of the aortic intact porcine bioprosthesis
    • Mullany CJ, Schaff HV, Orszulak TA, Miller FA. Early clinical and hemodynamic evaluation of the aortic intact porcine bioprosthesis. J Heart Valve Dis 1994;3:641-7.
    • (1994) J Heart Valve Dis , vol.3 , pp. 641-647
    • Mullany, C.J.1    Schaff, H.V.2    Orszulak, T.A.3    Miller, F.A.4
  • 12
    • 0018361555 scopus 로고
    • Influence of fixation condition on performance of glutaraldehyde-treated porcine aortic valves: Towards a more scientific basis
    • Broom N, Thomson EJ. Influence of fixation condition on performance of glutaraldehyde-treated porcine aortic valves: Towards a more scientific basis. Thorax 1979;34:166-76.
    • (1979) Thorax , vol.34 , pp. 166-176
    • Broom, N.1    Thomson, E.J.2
  • 13
    • 0024308401 scopus 로고
    • An assessment of the mechanical properties of leaflets from four second generation porcine bioprostheses with biaxial testing techniques
    • Mayne ASD, Christie GW, Smaill BH, Hunger PJ, BarrattBoyes BG. An assessment of the mechanical properties of leaflets from four second generation porcine bioprostheses with biaxial testing techniques. J Thorac Cardiovasc Surg 1989;98:170-80.
    • (1989) J Thorac Cardiovasc Surg , vol.98 , pp. 170-180
    • Mayne, A.S.D.1    Christie, G.W.2    Smaill, B.H.3    Hunger, P.J.4    BarrattBoyes, B.G.5
  • 14
    • 0026019929 scopus 로고
    • Analysis of Medtronic Intact bioprosthetic valve: Effects of "zero-pressure" fixation
    • Vesely I. Analysis of Medtronic Intact bioprosthetic valve: Effects of "zero-pressure" fixation. J Thorac Cardiovasc Surg 1991;101:90-9.
    • (1991) J Thorac Cardiovasc Surg , vol.101 , pp. 90-99
    • Vesely, I.1
  • 15
    • 0027390272 scopus 로고
    • Effects of fixation back pressure and antimineralization treatment on the morphology of porcine aortic bioprosthetic valves
    • Flomenbaum MA, Schoen FJ. Effects of fixation back pressure and antimineralization treatment on the morphology of porcine aortic bioprosthetic valves. J Thorac Cardiovasc Surg 1993;105:154-64.
    • (1993) J Thorac Cardiovasc Surg , vol.105 , pp. 154-164
    • Flomenbaum, M.A.1    Schoen, F.J.2
  • 16
    • 0012190240 scopus 로고
    • Inhibition of mineralization of glutaraldehydefixed Hancock bioprosthetic heart valves
    • Cohn LH, Galluci V, eds. New York: Yorke
    • Lentz D J, Pollock EM, Olsen DB, Andrews E J, Murashita J, Hartrip WL. Inhibition of mineralization of glutaraldehydefixed Hancock bioprosthetic heart valves. In: Cohn LH, Galluci V, eds. Cardiac Bioprostheses. New York: Yorke, 1982: 306-19.
    • (1982) Cardiac Bioprostheses , pp. 306-319
    • Lentz, D.J.1    Pollock, E.M.2    Olsen, D.B.3    Andrews, E.J.4    Murashita, J.5    Hartrip, W.L.6
  • 17
    • 0024384054 scopus 로고
    • Anticalcification treatments of bioprosthetic heart valves. In vivo, studies in sheep
    • Jones M, Eidbo EE, Hilbert SL, Ferrano V J, Clark RE. Anticalcification treatments of bioprosthetic heart valves. In vivo, studies in sheep. V Cardiac Surg 1989;4:69-73.
    • (1989) V Cardiac Surg , vol.4 , pp. 69-73
    • Jones, M.1    Eidbo, E.E.2    Hilbert, S.L.3    Ferrano J. V4    Clark, R.E.5
  • 18
    • 0024995193 scopus 로고
    • Rest and exercise hemodynamics of 20 to 23 mm allograft, Medtronic Intact (porcine), and St Jude Medical valves in the aortic position
    • Jaffe WM, Coverdale HA, Roch AH, Whitlock RM, Neutze JM, Barratt-Boyes BG. Rest and exercise hemodynamics of 20 to 23 mm allograft, Medtronic Intact (porcine), and St Jude Medical valves in the aortic position. J Thorac Cardiovasc Surg 1990;100:167-74.
    • (1990) J Thorac Cardiovasc Surg , vol.100 , pp. 167-174
    • Jaffe, W.M.1    Coverdale, H.A.2    Roch, A.H.3    Whitlock, R.M.4    Neutze, J.M.5    Barratt-Boyes, B.G.6
  • 19
    • 0030939379 scopus 로고    scopus 로고
    • Dynamic evaluation of the 21 mm Medtronic Intact aortic bioprosthesis by dobutamine echocardiography
    • Kadir I, Izzat MB, Wilde P, Reeves B, Bryan AJ, Angelini GD. Dynamic evaluation of the 21 mm Medtronic Intact aortic bioprosthesis by dobutamine echocardiography. Ann Thorac Surg 1997;63:1128-32.
    • (1997) Ann Thorac Surg , vol.63 , pp. 1128-1132
    • Kadir, I.1    Izzat, M.B.2    Wilde, P.3    Reeves, B.4    Bryan, A.J.5    Angelini, G.D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.