메뉴 건너뛰기




Volumn 17, Issue 11-12, 2002, Pages 1089-1094

Microbial biosensor array with transport mutants of Escherichia coli K12 for the simultaneous determination of mono-and disaccharides

Author keywords

Bacterial biosensors; Flow injection analysis; Sensor array; Sugar analysis; Transport mutants; Whole cell biosensor

Indexed keywords

CELLS; FRUCTOSE; GLUCOSE; METABOLISM; MICROBIAL ELECTRODES; MUTAGENESIS;

EID: 0036883710     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(02)00103-3     Document Type: Article
Times cited : (46)

References (26)
  • 1
    • 0034699619 scopus 로고    scopus 로고
    • New ways of enzymatic two-substrate determinations in flow injection systems
    • Becker T.M., Schmidt H.-L. New ways of enzymatic two-substrate determinations in flow injection systems. Anal. Chim. Acta. 421:2000;7-18.
    • (2000) Anal. Chim. Acta , vol.421 , pp. 7-18
    • Becker, T.M.1    Schmidt, H.-L.2
  • 7
  • 8
    • 0031773806 scopus 로고    scopus 로고
    • Biosensors for the measurement of toxicity of wastewaters to activated sludge
    • Evans M.R., Jordinson G.M., Rawson D.M., Rogerson J.G. Biosensors for the measurement of toxicity of wastewaters to activated sludge. Pesticide Sci. 54:1998;447-452.
    • (1998) Pesticide Sci. , vol.54 , pp. 447-452
    • Evans, M.R.1    Jordinson, G.M.2    Rawson, D.M.3    Rogerson, J.G.4
  • 11
    • 0030607267 scopus 로고    scopus 로고
    • Whole cell amperometric biosensor based on Aspergillus niger for determination of glucose with enhanced upper linearity limit
    • Katrlik J., Svorc J., Rosenberg M., Miertus S. Whole cell amperometric biosensor based on Aspergillus niger for determination of glucose with enhanced upper linearity limit. Anal. Chim. Acta. 331:1996;225-232.
    • (1996) Anal. Chim. Acta , vol.331 , pp. 225-232
    • Katrlik, J.1    Svorc, J.2    Rosenberg, M.3    Miertus, S.4
  • 12
    • 0032190792 scopus 로고    scopus 로고
    • A microbial sensor for detecting inhibitors of nitrification in wastewater
    • König A., Riedel K., Metzger J.W. A microbial sensor for detecting inhibitors of nitrification in wastewater. Biosensors Bioelectron. 13:1998;869-874.
    • (1998) Biosensors Bioelectron. , vol.13 , pp. 869-874
    • König, A.1    Riedel, K.2    Metzger, J.W.3
  • 15
    • 0028059826 scopus 로고
    • Monitoring BOD in the presence of heavy metal ions using a poly(4-vinylpyridine)-coated microbial sensor
    • Li F., Tan T.C. Monitoring BOD in the presence of heavy metal ions using a poly(4-vinylpyridine)-coated microbial sensor. Biosensors Bioelectron. 9:1994;445-455.
    • (1994) Biosensors Bioelectron. , vol.9 , pp. 445-455
    • Li, F.1    Tan, T.C.2
  • 16
    • 0025833671 scopus 로고
    • Flow-injection systems for the determination of oxidoreductase substrates - Applications in food quality control and process monitoring
    • Ogbomo I., Kittsteiner-Eberle R., Englbrecht U., Prinzing U., Danzer J., Schmidt H.-L. Flow-injection systems for the determination of oxidoreductase substrates - applications in food quality control and process monitoring. Anal. Chim. Acta. 249:1991;137-143.
    • (1991) Anal. Chim. Acta , vol.249 , pp. 137-143
    • Ogbomo, I.1    Kittsteiner-Eberle, R.2    Englbrecht, U.3    Prinzing, U.4    Danzer, J.5    Schmidt, H.-L.6
  • 17
    • 0029256639 scopus 로고
    • Sandwich enzyme membranes for amperometric multi-biosensor applications - Improvement of linearity and reduction of chemical cross-talk
    • Popp J., Silber A., Bräuchle C., Hampp N. Sandwich enzyme membranes for amperometric multi-biosensor applications - improvement of linearity and reduction of chemical cross-talk. Biosensors Bioelectron. 10:1995;243-249.
    • (1995) Biosensors Bioelectron. , vol.10 , pp. 243-249
    • Popp, J.1    Silber, A.2    Bräuchle, C.3    Hampp, N.4
  • 19
    • 0035021326 scopus 로고    scopus 로고
    • Characteristics of Gluconobacter oxydans B-1280 and Pichia methanolica MN4 cell based biosensors for detection of ethanol
    • Reshetilov A.N., Trotsenko J.A., Morozova N.O., Iliasov P.V., Ashin V.V. Characteristics of Gluconobacter oxydans B-1280 and Pichia methanolica MN4 cell based biosensors for detection of ethanol. Proc. Biochem. 36:2001;1015-1020.
    • (2001) Proc. Biochem. , vol.36 , pp. 1015-1020
    • Reshetilov, A.N.1    Trotsenko, J.A.2    Morozova, N.O.3    Iliasov, P.V.4    Ashin, V.V.5
  • 22
    • 0030367144 scopus 로고    scopus 로고
    • Flow-injection analysis systems with immobilized enzymes. Improvement of applicability by integration of coupled reactions, separation steps and background correction
    • Schmidt H.-L., Becker T., Ogbomo I., Schuhmann W. Flow-injection analysis systems with immobilized enzymes. Improvement of applicability by integration of coupled reactions, separation steps and background correction. Talanta. 43:1996;937-942.
    • (1996) Talanta , vol.43 , pp. 937-942
    • Schmidt, H.-L.1    Becker, T.2    Ogbomo, I.3    Schuhmann, W.4
  • 24
    • 0026152352 scopus 로고
    • Amperometric substrate determination in flow-injection systems with polypyrrole-enzyme electrodes
    • Schuhmann W. Amperometric substrate determination in flow-injection systems with polypyrrole-enzyme electrodes. Sens. Actuat. B - Chemical. 4:1991;41-49.
    • (1991) Sens. Actuat. B - Chemical , vol.4 , pp. 41-49
    • Schuhmann, W.1
  • 25
    • 0342466098 scopus 로고    scopus 로고
    • Methods in biotechnology, vol. 6: Enzyme and microbial biosensors: Techniques and protocols
    • A. Mulchandani, & K. Rogers. Totowa: Humana Press
    • Schuhmann W. Methods in biotechnology, vol. 6: enzyme and microbial biosensors: techniques and protocols. Mulchandani A., Rogers K., Enzyme Biosensors Based on Conducting Polymers. 1998;143-156 Humana Press, Totowa.
    • (1998) Enzyme Biosensors Based on Conducting Polymers , pp. 143-156
    • Schuhmann, W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.