Volumn 36, Issue 10, 2001, Pages 1015-1020

Characteristics of Gluconobacter oxydans B-1280 and Pichia methanolica MN4 cell based biosensors for detection of ethanol

Author keywords

Clark type electrode; Ethanol detection; Gluconobacter oxydans; Microbial sensors; Pichia methanolica

Indexed keywords

2 PROPANOL; ACETIC ACID; ALCOHOL; ARABINITOL; ARABINOSE; CITRIC ACID; GLUCOSE; GLYCEROL; METHANOL; PYRUVIC ACID; XYLITOL; XYLOSE;

EID: 0035021326     PISSN: 13595113     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0032-9592(01)00141-8     Document Type: Article
Times cited : (41)

References (18)
  • 1
    • 0028949867 scopus 로고
    • Flow analysis with membrane separation and time based sampling for ethanol determination in beer and wine
    • Mohns J, Kunnecke W. Flow analysis with membrane separation and time based sampling for ethanol determination in beer and wine. Anal Chim Acta 1995;305:241-7.
    • (1995) Anal Chim Acta , vol.305 , pp. 241-247
    • Mohns, J.1    Kunnecke, W.2
  • 2
    • 0029104315 scopus 로고
    • Simultaneous spectrofluorimetric determination of glycerol and ethanol in wine by flow injection using immobilized enzymes
    • Mattos IL, Fernandez-Romero JM, Luque De Castro MD, Valcarcel M. Simultaneous spectrofluorimetric determination of glycerol and ethanol in wine by flow injection using immobilized enzymes. Analyst 1995; 120:179-82.
    • (1995) Analyst , vol.120 , pp. 179-182
    • Mattos, I.L.1    Fernandez-Romero, J.M.2    De Luque Castro, M.D.3    Valcarcel, M.4
  • 3
    • 0028899594 scopus 로고
    • Simultaneous determination of alcohols and ethylene glycol in serum by packed- Or capillary-column gas chromatography
    • Livesey JF, Perkins SL, Tokessy NE, Maddock MJ. Simultaneous determination of alcohols and ethylene glycol in serum by packed- or capillary-column gas chromatography. Clin Chem 1995;41/2:300-5.
    • (1995) Clin Chem , vol.41 , Issue.2 , pp. 300-305
    • Livesey, J.F.1    Perkins, S.L.2    Tokessy, N.E.3    Maddock, M.J.4
  • 4
    • 0028189645 scopus 로고
    • Conductometric biosensor for ethanol detection based on whole yeast cells
    • Korpan Y, Dzyadevich S, Zharova V, El'skaya A. Conductometric biosensor for ethanol detection based on whole yeast cells. Ukr Biokhim Zhurn 1994;66:82-6.
    • (1994) Ukr Biokhim Zhurn , vol.66 , pp. 82-86
    • Korpan, Y.1    Dzyadevich, S.2    Zharova, V.3    El'Skaya, A.4
  • 5
    • 0028031787 scopus 로고
    • Enzyme-based biosensor as a selective detecton unit in column liquid chromatography
    • Marko-Varga G, Johansson K, Gorton L. Enzyme-based biosensor as a selective detecton unit in column liquid chromatography. J Chromatogr A 1994;660:153-67.
    • (1994) J Chromatogr A , vol.660 , pp. 153-167
    • Marko-Varga, G.1    Johansson, K.2    Gorton, L.3
  • 7
    • 0025280457 scopus 로고
    • Development of a sensor for ethanol
    • Koon WS. Development of a sensor for ethanol. Biosen Bioelectron 1990;5:311-25.
    • (1990) Biosen Bioelectron , vol.5 , pp. 311-325
    • Koon, W.S.1
  • 8
    • 0028197033 scopus 로고
    • Electrocatalytic oxidation of reduced nicotinamide coenzymes at methylene green-modified electrodes and fabrication of amperometric alcohol biosensors
    • Qijin C, Shaojun D. Electrocatalytic oxidation of reduced nicotinamide coenzymes at methylene green-modified electrodes and fabrication of amperometric alcohol biosensors. Anal Chim Acta 1994;285:125-33.
    • (1994) Anal Chim Acta , vol.285 , pp. 125-133
    • Qijin, C.1    Shaojun, D.2
  • 10
    • 0027498260 scopus 로고
    • Methylotrophic yeast microbiosensor based on ion-sensitive field effect transistor for methanol and ethanol determination
    • Korpan Y, Soldatkin A, Starodub N, El'skaya A, et al. Methylotrophic yeast microbiosensor based on ion-sensitive field effect transistor for methanol and ethanol determination. Anal Chim Acta 1993;271:203-8.
    • (1993) Anal Chim Acta , vol.271 , pp. 203-208
    • Korpan, Y.1    Soldatkin, A.2    Starodub, N.3    El'Skaya, A.4
  • 11
    • 26944475834 scopus 로고
    • Turner APF, Karube I, Wilson GS, editors. Moscow: Mir Publishers
    • Karube I. In: Turner APF, Karube I, Wilson GS, editors. Biosensors. Fundamentals and applications. Moscow: Mir Publishers, 1992:20 33.
    • (1992) Biosensors. Fundamentals and Applications , vol.20 , pp. 33
    • Karube, I.1
  • 13
    • 0001553812 scopus 로고
    • Immobilized cells of Gluconobacter oxydans as a receptor element of a glucose sensor
    • Reshetilov A, Donova M, Koshcheyenko K. Immobilized cells of Gluconobacter oxydans as a receptor element of a glucose sensor. Appl Biochem Microbiol (Russian) 1992;28:518-24.
    • (1992) Appl Biochem Microbiol (Russian) , vol.28 , pp. 518-524
    • Reshetilov, A.1    Donova, M.2    Koshcheyenko, K.3
  • 14
    • 84987492148 scopus 로고
    • Carbon paste electrodes modified with enzymes, tissues and cells
    • Gorton L. Carbon paste electrodes modified with enzymes, tissues and cells. Electroanalysis 1995;2:23-45.
    • (1995) Electroanalysis , vol.2 , pp. 23-45
    • Gorton, L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.