메뉴 건너뛰기




Volumn 17, Issue 11-12, 2002, Pages 973-981

Bio-smart hydrogels: Co-joined molecular recognition and signal transduction in biosensor fabrication and drug delivery

Author keywords

Acetaminophen; Ascorbic acid; Cholesterol; Conducting electroactive polymers; Galactose; Glucose; Hydrogel; Insulin; Uric acid

Indexed keywords

BIOSENSORS; CHOLESTEROL; CONTROLLED DRUG DELIVERY; ENZYMES; GLUCOSE; HYDROGELS; PH EFFECTS; PHYSIOLOGY; POLYMERS; PROSTHETICS;

EID: 0036883536     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(02)00089-1     Document Type: Article
Times cited : (113)

References (25)
  • 1
    • 0031873729 scopus 로고    scopus 로고
    • Characterisation and analytical use of a polypyrrole electrode containing anti-human serum albumin
    • Barisci J.N., Hughes D., Minett A., Wallace G.G. Characterisation and analytical use of a polypyrrole electrode containing anti-human serum albumin. Anal. Chim. Acta. 371:1998;39-48.
    • (1998) Anal. Chim. Acta , vol.371 , pp. 39-48
    • Barisci, J.N.1    Hughes, D.2    Minett, A.3    Wallace, G.G.4
  • 2
    • 0029583977 scopus 로고
    • Improvement of the analytical characteristics of an enzyme electrode for free and total cholesterol via laponite clay additives
    • Besombes J.-L., Cosnier S., Labbe P., Reverdy G. Improvement of the analytical characteristics of an enzyme electrode for free and total cholesterol via laponite clay additives. Anal. Chim. Acta. 317:1995;275-280.
    • (1995) Anal. Chim. Acta , vol.317 , pp. 275-280
    • Besombes, J.-L.1    Cosnier, S.2    Labbe, P.3    Reverdy, G.4
  • 3
    • 0036134835 scopus 로고    scopus 로고
    • Polypyrrole-hydrogel composites for the construction of clinically important biosensors
    • Brahim S., Narinesingh D., Guiseppi-Elie A. Polypyrrole-hydrogel composites for the construction of clinically important biosensors. Biosens. Bioelectronics. 17:2002;53-59.
    • (2002) Biosens. Bioelectronics , vol.17 , pp. 53-59
    • Brahim, S.1    Narinesingh, D.2    Guiseppi-Elie, A.3
  • 4
    • 0035804102 scopus 로고    scopus 로고
    • Amperometric determination of cholesterol in serum using a biosensor of cholesterol oxidase contained within a polypyrrole-hydrogel membrane
    • Brahim S., Narinesingh D., Guiseppi-Elie A. Amperometric determination of cholesterol in serum using a biosensor of cholesterol oxidase contained within a polypyrrole-hydrogel membrane. Anal. Chim. Acta. 448:2001;27-36.
    • (2001) Anal. Chim. Acta , vol.448 , pp. 27-36
    • Brahim, S.1    Narinesingh, D.2    Guiseppi-Elie, A.3
  • 5
    • 0029075404 scopus 로고
    • Continuous in vivo monitoring in diabetes: The subcutaneous glucose concentration
    • Fischer U. Continuous in vivo monitoring in diabetes: the subcutaneous glucose concentration. Acta Anaesthesiol. Scand. 39:1995;21-29.
    • (1995) Acta Anaesthesiol. Scand. , vol.39 , pp. 21-29
    • Fischer, U.1
  • 6
    • 84987564494 scopus 로고
    • Evaluation of Nafion as media for glucose oxidase immobilization for the development of an amperometric glucose biosensor
    • Fortier G., Vaillancourt M., Belanger D. Evaluation of Nafion as media for glucose oxidase immobilization for the development of an amperometric glucose biosensor. Electroanalysis. 4:1992;275-283.
    • (1992) Electroanalysis , vol.4 , pp. 275-283
    • Fortier, G.1    Vaillancourt, M.2    Belanger, D.3
  • 7
    • 0035923327 scopus 로고    scopus 로고
    • Enzyme microgels in packed-bed bioreactors with downstream amperometric detection using microfabricated interdigitated microsensor electrode arrays
    • Guiseppi-Elie A., Sheppard N.F. Jr., Brahim S., Narinesingh D. Enzyme microgels in packed-bed bioreactors with downstream amperometric detection using microfabricated interdigitated microsensor electrode arrays. Biotech. Bioeng. 75:2001;475-484.
    • (2001) Biotech. Bioeng. , vol.75 , pp. 475-484
    • Guiseppi-Elie, A.1    Sheppard N.F., Jr.2    Brahim, S.3    Narinesingh, D.4
  • 9
    • 0031259910 scopus 로고    scopus 로고
    • Polymerized colloidal crystal hydrogel films as intelligent chemical sensing materials
    • Holtz J.H., Asher S.A. Polymerized colloidal crystal hydrogel films as intelligent chemical sensing materials. Nature. 389:1997;829-832.
    • (1997) Nature , vol.389 , pp. 829-832
    • Holtz, J.H.1    Asher, S.A.2
  • 10
    • 0000092040 scopus 로고    scopus 로고
    • Bioinspired phospholipid polymer biomaterials for making high performance artificial organs
    • Ishihara K. Bioinspired phospholipid polymer biomaterials for making high performance artificial organs. Sci. Technol. Adv. Mater. 1:2000;131-138.
    • (2000) Sci. Technol. Adv. Mater. , vol.1 , pp. 131-138
    • Ishihara, K.1
  • 12
    • 0031882484 scopus 로고    scopus 로고
    • Amperometric biosensor sensitive to glucose and lactose based on co-immobilization of ferrocene, glucose oxidase, β-galactosidase and mutarotase in β-cyclodextrin polymer
    • Liu H., Li H., Ying T., Sun K., Qin Y., Qi D. Amperometric biosensor sensitive to glucose and lactose based on co-immobilization of ferrocene, glucose oxidase, β-galactosidase and mutarotase in β-cyclodextrin polymer. Anal. Chim. Acta. 358:1998;137-144.
    • (1998) Anal. Chim. Acta , vol.358 , pp. 137-144
    • Liu, H.1    Li, H.2    Ying, T.3    Sun, K.4    Qin, Y.5    Qi, D.6
  • 13
    • 0033552944 scopus 로고    scopus 로고
    • Entropic trapping of macromolecules by mesoscopic periodic voids in a polymer hydrogel
    • Liu L., Li P., Asher S.A. Entropic trapping of macromolecules by mesoscopic periodic voids in a polymer hydrogel. Nature. 397:1999;141-144.
    • (1999) Nature , vol.397 , pp. 141-144
    • Liu, L.1    Li, P.2    Asher, S.A.3
  • 14
    • 0029395019 scopus 로고
    • Immobilization of glucose oxidase in the regenerated silk fibroin membrane: Characterization of the membrane structure and its application to an amperometric glucose sensor employing ferrocene as electron shuttle
    • Liu Y., Liu H., Qian J., Deng J., Yu T. Immobilization of glucose oxidase in the regenerated silk fibroin membrane: characterization of the membrane structure and its application to an amperometric glucose sensor employing ferrocene as electron shuttle. J. Chem. Technol. Biotechnol. 64:1995;269-276.
    • (1995) J. Chem. Technol. Biotechnol. , vol.64 , pp. 269-276
    • Liu, Y.1    Liu, H.2    Qian, J.3    Deng, J.4    Yu, T.5
  • 15
    • 0000982624 scopus 로고
    • Elimination of electrooxidizable interferents in glucose electrodes
    • Maidan R., Heller A. Elimination of electrooxidizable interferents in glucose electrodes. J. Am. Chem. Soc. 113:1991;9003-9004.
    • (1991) J. Am. Chem. Soc. , vol.113 , pp. 9003-9004
    • Maidan, R.1    Heller, A.2
  • 16
    • 0036027616 scopus 로고    scopus 로고
    • In vivo biocompatibility and degradability of a novel injectable-chitosan-based implant
    • Mi F.-L., Tan Y.-C., Liang H.-F., Sung H.-W. In vivo biocompatibility and degradability of a novel injectable-chitosan-based implant. Biomaterials. 23:2002;181-191.
    • (2002) Biomaterials , vol.23 , pp. 181-191
    • Mi, F.-L.1    Tan, Y.-C.2    Liang, H.-F.3    Sung, H.-W.4
  • 17
    • 0032007128 scopus 로고    scopus 로고
    • In vitro and in vivo mineralization of Nafion membrane used for implantable glucose sensors
    • Moussy F., Mercado R.C. In vitro and in vivo mineralization of Nafion membrane used for implantable glucose sensors. Bios. Bioelectron. 13:1998;133-145.
    • (1998) Bios. Bioelectron. , vol.13 , pp. 133-145
    • Moussy, F.1    Mercado, R.C.2
  • 18
    • 0030933561 scopus 로고    scopus 로고
    • Enzyme modified amperometric sensors for choline and acetylcholine with tetrathiafulvalene tetracyanoquinodimethane as the electron-transfer mediator
    • Quan X., Wightman M. Enzyme modified amperometric sensors for choline and acetylcholine with tetrathiafulvalene tetracyanoquinodimethane as the electron-transfer mediator. Anal. Chim. Acta. 341:1997;43-51.
    • (1997) Anal. Chim. Acta , vol.341 , pp. 43-51
    • Quan, X.1    Wightman, M.2
  • 19
    • 0031429763 scopus 로고    scopus 로고
    • Biocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors
    • Quinn C., Connor R., Heller A. Biocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors. Biomaterials. 18:1997;1665-1670.
    • (1997) Biomaterials , vol.18 , pp. 1665-1670
    • Quinn, C.1    Connor, R.2    Heller, A.3
  • 20
    • 0030595034 scopus 로고    scopus 로고
    • In situ biochemical reduction of interference in an amperometric biosensor with a novel heterobilayer configuration of polypyrrole/glucose oxidase/horseradish peroxidase
    • Shin M.-C., Yoon H.C., Kim H.-S. In situ biochemical reduction of interference in an amperometric biosensor with a novel heterobilayer configuration of polypyrrole/glucose oxidase/horseradish peroxidase. Anal. Chim. Acta. 329:1996;223-230.
    • (1996) Anal. Chim. Acta , vol.329 , pp. 223-230
    • Shin, M.-C.1    Yoon, H.C.2    Kim, H.-S.3
  • 21
    • 0027475964 scopus 로고
    • Thrombin and albumin adsorption to PVA and heparin-PVA hydrogels. 2. Competition and displacement
    • Smith B.A., Sefton M.V. Thrombin and albumin adsorption to PVA and heparin-PVA hydrogels. 2. Competition and displacement. J. Biomed. Mater. Res. 27:1993;89-95.
    • (1993) J. Biomed. Mater. Res. , vol.27 , pp. 89-95
    • Smith, B.A.1    Sefton, M.V.2
  • 22
    • 0029765767 scopus 로고    scopus 로고
    • Application of biosensor for monitoring galactose content
    • Szabó E.E., Adányi N., Váradi M. Application of biosensor for monitoring galactose content. Bios. Bioelectron. 11:1996;1051-1058.
    • (1996) Bios. Bioelectron. , vol.11 , pp. 1051-1058
    • Szabó, E.E.1    Adányi, N.2    Váradi, M.3
  • 23
    • 0032999633 scopus 로고    scopus 로고
    • In situ preparation of a cholesterol biosensor: Entrapment of cholesterol oxidase in an overoxidized polypyrrole film electrodeposited in a flow system, determination of total cholesterol in serum
    • Vidal J.C., Garcia E., Castillo J.R. In situ preparation of a cholesterol biosensor: entrapment of cholesterol oxidase in an overoxidized polypyrrole film electrodeposited in a flow system, determination of total cholesterol in serum. Anal. Chim. Acta. 385:1999;213-222.
    • (1999) Anal. Chim. Acta , vol.385 , pp. 213-222
    • Vidal, J.C.1    Garcia, E.2    Castillo, J.R.3
  • 25
    • 0031058434 scopus 로고    scopus 로고
    • A needle-type sensor for monitoring glucose in whole blood
    • Yang Q., Atanasov P., Wilkins E. A needle-type sensor for monitoring glucose in whole blood. Biomed. Instrum. Technol. 31:1997;54-62.
    • (1997) Biomed. Instrum. Technol. , vol.31 , pp. 54-62
    • Yang, Q.1    Atanasov, P.2    Wilkins, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.