메뉴 건너뛰기




Volumn 18, Issue 24, 1997, Pages 1665-1670

Biocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors

Author keywords

Biocompatibility; Biosensors; Glucose oxidase; Poly(ethylene glycol); Subcutaneous

Indexed keywords

BACTERIOPHAGES; BIOCOMPATIBILITY; COLLAGEN; CROSSLINKING; ELECTROCHEMICAL ELECTRODES; GLUCOSE; HYDROGELS; POLYETHYLENE GLYCOLS;

EID: 0031429763     PISSN: 01429612     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0142-9612(97)00125-7     Document Type: Article
Times cited : (113)

References (32)
  • 1
    • 20344405031 scopus 로고
    • Redox polymers containing enzymes. 1. A redox conducting epoxy cement: Synthesis, characterization and electrocatalytic oxidation of hydroquinone
    • 1. Gregg, B. A. and Heller, A., Redox polymers containing enzymes. 1. A redox conducting epoxy cement: synthesis, characterization and electrocatalytic oxidation of hydroquinone. J. Phys. Chem., 1991, 95, 5970-5975.
    • (1991) J. Phys. Chem. , vol.95 , pp. 5970-5975
    • Gregg, B.A.1    Heller, A.2
  • 2
    • 0026425799 scopus 로고
    • Amperometric glucose microelectrodes prepared through immobilization of glucose oxidase in redox hydrogels
    • 2. Pishko, M. V., Michael, A. C. and Heller, A., Amperometric glucose microelectrodes prepared through immobilization of glucose oxidase in redox hydrogels. Anal. Chem., 1991, 63, 2268-2272.
    • (1991) Anal. Chem. , vol.63 , pp. 2268-2272
    • Pishko, M.V.1    Michael, A.C.2    Heller, A.3
  • 3
    • 0026216348 scopus 로고
    • Design and in vitro studies of needle-type glucose sensor for subcutaneous monitoring
    • 3. Bindra, D. S., Zhang, Y. and Wilson, G. S., Design and in vitro studies of needle-type glucose sensor for subcutaneous monitoring. Anal. Chem. 1991, 63, 1692-1696.
    • (1991) Anal. Chem. , vol.63 , pp. 1692-1696
    • Bindra, D.S.1    Zhang, Y.2    Wilson, G.S.3
  • 4
    • 0027214964 scopus 로고
    • A glucose monitoring system for on-line estimation in man of blood glucose concentrations using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit
    • 4. Poitout, V., Moatti-Sirat, D., Reach, G. et al., A glucose monitoring system for on-line estimation in man of blood glucose concentrations using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit. Diabetologia, 1993, 36, 658-663.
    • (1993) Diabetologia , vol.36 , pp. 658-663
    • Poitout, V.1    Moatti-Sirat, D.2    Reach, G.3
  • 6
    • 0025835293 scopus 로고
    • Determination of urate in undiluted whole blood by enzyme electrode
    • 6. Keedy, F. H. and Vadgama, P., Determination of urate in undiluted whole blood by enzyme electrode. Biosensors Bioelectronics 1991, 6, 491-499.
    • (1991) Biosensors Bioelectronics , vol.6 , pp. 491-499
    • Keedy, F.H.1    Vadgama, P.2
  • 7
    • 0024824570 scopus 로고
    • Glucose electrochemical probe with extended linearity for whole blood
    • 7. Mascini, M., Selleri, M. and Riviello, M., Glucose electrochemical probe with extended linearity for whole blood. J. Pharm. Biomed. Anal. 1989, 7, 1507-1512.
    • (1989) J. Pharm. Biomed. Anal. , vol.7 , pp. 1507-1512
    • Mascini, M.1    Selleri, M.2    Riviello, M.3
  • 8
    • 0024541965 scopus 로고
    • In vivo molecular sensing in diabetes mellitus: An implantable glucose sensor with direct electron transfer
    • 8. Pickup, J. C., Shaw, G. S. and Claremont, D. J. In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transfer. Diabetologia, 1989, 32, 213-317.
    • (1989) Diabetologia , vol.32 , pp. 213-317
    • Pickup, J.C.1    Shaw, G.S.2    Claremont, D.J.3
  • 10
    • 0025689061 scopus 로고
    • Application of chronic intravascular blood glucose sensor in dogs
    • 10. Armour, J. C., Lucisano, J. Y., McKean, B. D. and Gough, D. A., Application of chronic intravascular blood glucose sensor in dogs. Diabetes, 1990, 39, 1519-1526.
    • (1990) Diabetes , vol.39 , pp. 1519-1526
    • Armour, J.C.1    Lucisano, J.Y.2    McKean, B.D.3    Gough, D.A.4
  • 11
    • 0025731433 scopus 로고
    • Preliminary in vivo biocompatibility studies on perfluorosulphonic acid polymer membranes for biosensor application
    • 11. Turner, R. F., Harrison, D. J. and Rajotte, R. V., Preliminary in vivo biocompatibility studies on perfluorosulphonic acid polymer membranes for biosensor application. Biomaterials 1991, 12, 361-368.
    • (1991) Biomaterials , vol.12 , pp. 361-368
    • Turner, R.F.1    Harrison, D.J.2    Rajotte, R.V.3
  • 12
    • 0026021952 scopus 로고
    • Poly(vinyl alcohol)-heparin hydrogels as sensor catheter membranes
    • 12. Brinkman, E., Van Der Does, L. and Bantjes, A., Poly(vinyl alcohol)-heparin hydrogels as sensor catheter membranes. Biomaterials, 1991, 12, 63-70.
    • (1991) Biomaterials , vol.12 , pp. 63-70
    • Brinkman, E.1    Van Der Does, L.2    Bantjes, A.3
  • 13
    • 0029256670 scopus 로고
    • Photo-crosslinked copolymers of 2-hydroxyethyl methacrylate, poly(ethylene glycol) tetra-acrylate and ethylene dimethacrylate for improving biocompatibility of biosensors
    • 13. Quinn, C. P., Pathak, C. P., Heller, A. and Hubbell, J. A., Photo-crosslinked copolymers of 2-hydroxyethyl methacrylate, poly(ethylene glycol) tetra-acrylate and ethylene dimethacrylate for improving biocompatibility of biosensors. Biomaterials, 1995, 16, 389-396.
    • (1995) Biomaterials , vol.16 , pp. 389-396
    • Quinn, C.P.1    Pathak, C.P.2    Heller, A.3    Hubbell, J.A.4
  • 14
    • 0029917196 scopus 로고    scopus 로고
    • Portable device for continuous fractionated blood sampling and ex vivo blood glucose monitoring
    • 14. Trajinoski, Z., Wach, P. and Gfrerer, R. et al., Portable device for continuous fractionated blood sampling and ex vivo blood glucose monitoring. Biosensors Bioelectronics, 1996, 11, 479-487.
    • (1996) Biosensors Bioelectronics , vol.11 , pp. 479-487
    • Trajinoski, Z.1    Wach, P.2    Gfrerer, R.3
  • 15
    • 0030021393 scopus 로고    scopus 로고
    • Covalently immobilized enzymes on biocompatible polymers for amperometric sensor applications
    • 15. Doretti, L., Ferrara, D., Gattolin, P. and Lora, S., Covalently immobilized enzymes on biocompatible polymers for amperometric sensor applications. Biosensors Bioelectronics, 1996, 11, 365-373.
    • (1996) Biosensors Bioelectronics , vol.11 , pp. 365-373
    • Doretti, L.1    Ferrara, D.2    Gattolin, P.3    Lora, S.4
  • 16
    • 0029294501 scopus 로고
    • Development of ferrocene-mediated needle-type glucose sensor covered with newly designed biocompatible membrane, 2-methylacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate
    • 16. Nishida, K., Sakakida, M., Ichinose, K. et al., Development of ferrocene-mediated needle-type glucose sensor covered with newly designed biocompatible membrane, 2-methylacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate. Med. Prog. Technol., 1995, 21, 91-103.
    • (1995) Med. Prog. Technol. , vol.21 , pp. 91-103
    • Nishida, K.1    Sakakida, M.2    Ichinose, K.3
  • 17
    • 0029256705 scopus 로고
    • Glucose biosensor with enzyme entrapped in polymer coating
    • 17. Yang, S., Atanasov, P. and Wilkins, E., Glucose biosensor with enzyme entrapped in polymer coating. Biomed. Instrum. Technol., 1995a, 29, 125-133.
    • (1995) Biomed. Instrum. Technol. , vol.29 , pp. 125-133
    • Yang, S.1    Atanasov, P.2    Wilkins, E.3
  • 18
    • 0028996143 scopus 로고
    • Improvement in the long-term stability of an amperometric glucose sensor system by introducing a cellulose membrane of bacterial origin
    • 18. Ammon, H. P., Ege, W., Opperman, M., Gopel, W. and Eisele, S., Improvement in the long-term stability of an amperometric glucose sensor system by introducing a cellulose membrane of bacterial origin. Anal. Chem., 1995, 67, 466-471.
    • (1995) Anal. Chem. , vol.67 , pp. 466-471
    • Ammon, H.P.1    Ege, W.2    Opperman, M.3    Gopel, W.4    Eisele, S.5
  • 19
    • 0029450918 scopus 로고
    • Study of cellulose acetate membrane-based glucose biosensors
    • 19. Wang, S., Ji, X., Yuan, Z., Study of cellulose acetate membrane-based glucose biosensors. Chinese J. Biotechnol., 1995, 11, 199-205.
    • (1995) Chinese J. Biotechnol. , vol.11 , pp. 199-205
    • Wang, S.1    Ji, X.2    Yuan, Z.3
  • 20
    • 0029394742 scopus 로고
    • Glucose biosensor on oxygen electrode with sandwich-type membranes
    • 20. Yang, S., Atanasov, P. and Wilkins, E., Glucose biosensor on oxygen electrode with sandwich-type membranes. Ann. Biomed. Eng., 1995b, 23, 833-839.
    • (1995) Ann. Biomed. Eng. , vol.23 , pp. 833-839
    • Yang, S.1    Atanasov, P.2    Wilkins, E.3
  • 21
    • 0029084208 scopus 로고
    • Effect of interference on the performance of glucose enzyme electrodes using Nafion coatings
    • 21. Vaidya, R., Atanasov, P. and Wilkins, E., Effect of interference on the performance of glucose enzyme electrodes using Nafion coatings. Med. Eng. Phys., 1995, 17, 416-424.
    • (1995) Med. Eng. Phys. , vol.17 , pp. 416-424
    • Vaidya, R.1    Atanasov, P.2    Wilkins, E.3
  • 22
    • 0027650815 scopus 로고
    • Performance of subcutaneously implanted needle-type glucose sensors employing a novel trilayer coating
    • 22. Moussy, F., Harrison, D. J., O'Brien, D.W. and Rajotte, R. V., Performance of subcutaneously implanted needle-type glucose sensors employing a novel trilayer coating. Anal. Chem., 1993, 65, 2072-2077.
    • (1993) Anal. Chem. , vol.65 , pp. 2072-2077
    • Moussy, F.1    Harrison, D.J.2    O'Brien, D.W.3    Rajotte, R.V.4
  • 23
    • 0028533426 scopus 로고
    • In vitro and in vivo performance and lifetime of perfluorinated ionomer-coated glucose sensors after high-temperature coating
    • 23. Moussy, F., Jakeway, S., Harrison, D. J. and Rajotte, R. V., In vitro and in vivo performance and lifetime of perfluorinated ionomer-coated glucose sensors after high-temperature coating. Anal. Chem., 1994, 66, 3882-3888.
    • (1994) Anal. Chem. , vol.66 , pp. 3882-3888
    • Moussy, F.1    Jakeway, S.2    Harrison, D.J.3    Rajotte, R.V.4
  • 24
    • 0027934171 scopus 로고
    • Flow injection analysis for glucose using an amperometric enzyme electrode based on lipid-modified glucose oxidase as the detector
    • 24. Mizutani, F. and Yabuki, S., Flow injection analysis for glucose using an amperometric enzyme electrode based on lipid-modified glucose oxidase as the detector. Biosensors Bioelectronics, 1994, 9, 411-414.
    • (1994) Biosensors Bioelectronics , vol.9 , pp. 411-414
    • Mizutani, F.1    Yabuki, S.2
  • 25
    • 0026546742 scopus 로고
    • Towards continuous glucose monitoring: In vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue
    • 25. Moatti-Sirat, D., Capron, F., Poitout, V. et al., Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue. Diabetologia, 1992, 35, 224-230.
    • (1992) Diabetologia , vol.35 , pp. 224-230
    • Moatti-Sirat, D.1    Capron, F.2    Poitout, V.3
  • 26
    • 0027102347 scopus 로고
    • In vivo evaluation of an electroenzymatic glucose sensor implanted in subcutaneous tissue
    • 26. Johnson, K. W., Mastrototaro, J. J., Howey, D. C. et al., In vivo evaluation of an electroenzymatic glucose sensor implanted in subcutaneous tissue. Biosensors Bioelectronics 1992, 7, 709-714.
    • (1992) Biosensors Bioelectronics , vol.7 , pp. 709-714
    • Johnson, K.W.1    Mastrototaro, J.J.2    Howey, D.C.3
  • 27
    • 0026491971 scopus 로고
    • Calibration in dogs of a subcutaneous miniaturized glucose sensor using a glucose meter for blood glucose determination
    • 27. Poitout, V., Moatti-Sirat, D. and Reach, G., Calibration in dogs of a subcutaneous miniaturized glucose sensor using a glucose meter for blood glucose determination. Biosensors Bioelectronics, 1992, 7, 587-592.
    • (1992) Biosensors Bioelectronics , vol.7 , pp. 587-592
    • Poitout, V.1    Moatti-Sirat, D.2    Reach, G.3
  • 28
    • 0028106630 scopus 로고
    • Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model
    • 28. Gilligan, B. J., Shults, M. C., Rhodes, R. K. and Updike, S. J., Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model. Diabetes Care, 1994, 17, 882-887.
    • (1994) Diabetes Care , vol.17 , pp. 882-887
    • Gilligan, B.J.1    Shults, M.C.2    Rhodes, R.K.3    Updike, S.J.4
  • 30
    • 0029256656 scopus 로고
    • Open flow microperfusion: Approach to in vivo glucose monitoring
    • 30. Rigby, G. P., Crump, P. and Vadgama, P., Open flow microperfusion: approach to in vivo glucose monitoring. Med. Bio. Eng. Comput., 1995, 33, 231-234.
    • (1995) Med. Bio. Eng. Comput. , vol.33 , pp. 231-234
    • Rigby, G.P.1    Crump, P.2    Vadgama, P.3
  • 31
    • 0029883087 scopus 로고    scopus 로고
    • Stabilized needle electrode system for in vivo glucose monitoring based on open flow microperfusion
    • 31. Rigby, G. P., Crump, P. and Vadgama, P., Stabilized needle electrode system for in vivo glucose monitoring based on open flow microperfusion. Analyst, 1996, 121, 871-875.
    • (1996) Analyst , vol.121 , pp. 871-875
    • Rigby, G.P.1    Crump, P.2    Vadgama, P.3
  • 32
    • 0028520531 scopus 로고
    • Design, characterization and one-point in vivo calibration of a subcutaneously implanted glucose electrode
    • 32. Csöregi, E., Quinn, C. P., Schmidtke, D. W. et al., Design, characterization and one-point in vivo calibration of a subcutaneously implanted glucose electrode. Anal. Chem., 1994, 66, 3131-3138.
    • (1994) Anal. Chem. , vol.66 , pp. 3131-3138
    • Csöregi, E.1    Quinn, C.P.2    Schmidtke, D.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.