메뉴 건너뛰기




Volumn 10, Issue 11, 2002, Pages 1301-1308

Control aspects of a robotic haptic interface for kinesthetic knee joint simulation

Author keywords

Admittance; Force feedback; Haptic interface; Impedance; Orthopaedic simulator; Performance; Robot control; Virtual reality

Indexed keywords

CONTROL EQUIPMENT; HARDWARE; MOTION CONTROL; ORTHOPEDICS; ROBOTICS;

EID: 0036872649     PISSN: 09670661     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0967-0661(02)00085-0     Document Type: Article
Times cited : (16)

References (22)
  • 5
    • 0012599088 scopus 로고    scopus 로고
    • Stability and mode switching in closed-loop teleoperation systems
    • Baier, H., Buss, M., & Schmidt, G. (2000). Stability and mode switching in closed-loop teleoperation systems. Automatisierungs-technik, 48(2), 51-59.
    • (2000) Automatisierungs-technik , vol.48 , Issue.2 , pp. 51-59
    • Baier, H.1    Buss, M.2    Schmidt, G.3
  • 7
    • 0033221954 scopus 로고    scopus 로고
    • A control-system architecture for robots used to simulate dynamic force and moment interaction between humans and virtual objects
    • Clover, C. L. (1999). A control-system architecture for robots used to simulate dynamic force and moment interaction between humans and virtual objects. IEEE Transactions on Systems, Man and Cybernetics, 29(4), 481-493.
    • (1999) IEEE Transactions on Systems, Man and Cybernetics , vol.29 , Issue.4 , pp. 481-493
    • Clover, C.L.1
  • 9
    • 3042577574 scopus 로고    scopus 로고
    • Freedom-7: A high fidelity seven axis haptic device with application to surgical training
    • A. Casals, & A. T. de Almeida (Eds.). Berlin: Springer
    • Hayward, V., Gregorio, P., Astley, O., Greenish, S., Doyon, M., & Lessard, L., et al. (1998). Freedom-7: A high fidelity seven axis haptic device with application to surgical training. In A. Casals. & A. T. de Almeida (Eds.). Experimental robotics V. Berlin: Springer.
    • (1998) Experimental Robotics V
    • Hayward, V.1    Gregorio, P.2    Astley, O.3    Greenish, S.4    Doyon, M.5    Lessard, L.6
  • 11
    • 0027678261 scopus 로고
    • Stability and transparency in bilateral teleoperation
    • Lawrence, D. A. (1993). Stability and transparency in bilateral teleoperation. IEEE Transactions on Robotics and Automation. 9(5), 624-637.
    • (1993) IEEE Transactions on Robotics and Automation , vol.9 , Issue.5 , pp. 624-637
    • Lawrence, D.A.1
  • 19
    • 0030247562 scopus 로고    scopus 로고
    • Biomechanical model of the human knee evaluated by neuromuscular stimulation
    • Riener, R., Quintern, J., & Schmidt, G. (1996). Biomechanical model of the human knee evaluated by neuromuscular stimulation. Journal of Biomechanics, 29, 1157-1167.
    • (1996) Journal of Biomechanics , vol.29 , pp. 1157-1167
    • Riener, R.1    Quintern, J.2    Schmidt, G.3
  • 21
    • 84861942362 scopus 로고    scopus 로고
    • Design and application of digital FIR differentiators using modulating functions
    • Santa Barbara
    • Wolfram, A., & Moseler, O. (2000). Design and application of digital FIR differentiators using modulating functions. In Proceedings of the IFAC SYSID conference. Santa Barbara.
    • (2000) Proceedings of the IFAC SYSID Conference
    • Wolfram, A.1    Moseler, O.2
  • 22
    • 0040038143 scopus 로고    scopus 로고
    • WYSIWYF display: A visual/haptic interface to virtual environment
    • Yokokohji, Y., Hollis, R.L., & Kanade, T. (1999). WYSIWYF display: A visual/haptic interface to virtual environment. Presence, 8(4), 412-434.
    • (1999) Presence , vol.8 , Issue.4 , pp. 412-434
    • Yokokohji, Y.1    Hollis, R.L.2    Kanade, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.