메뉴 건너뛰기




Volumn 28, Issue 11-12, 2002, Pages 1491-1497

The ability of quantitative ultrasound at the calcaneus to identify postmenopausal women with different types of nontraumatic fractures

Author keywords

Calcaneus; Fractures; Quantitative ultrasound; Women

Indexed keywords

FRACTURE; HEALTH CARE;

EID: 0036865940     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(02)00619-1     Document Type: Article
Times cited : (25)

References (27)
  • 1
    • 0023687444 scopus 로고
    • Ultrasound attenuation of the os calcis in women with osteoporosis and hip fractures
    • Baran D.T., Kelly A.M., Karellas A., et al. Ultrasound attenuation of the os calcis in women with osteoporosis and hip fractures. Calcif Tissue Int. 43:1988;138-142.
    • (1988) Calcif Tissue Int , vol.43 , pp. 138-142
    • Baran, D.T.1    Kelly, A.M.2    Karellas, A.3
  • 2
    • 0030790117 scopus 로고    scopus 로고
    • The combined use of ultrasound and densitometry in the prediction of vertebral fracture
    • Cepollaro C., Gonnelli S., Pondrelli C., et al. The combined use of ultrasound and densitometry in the prediction of vertebral fracture. Br J Radiol. 70:1997;691-696.
    • (1997) Br J Radiol , vol.70 , pp. 691-696
    • Cepollaro, C.1    Gonnelli, S.2    Pondrelli, C.3
  • 3
    • 0032828751 scopus 로고    scopus 로고
    • Calcaneal ultrasound attenuation in an elderly population: Measurement position and relationships with body size and past fractures
    • Donaldson M.M.K., McGrother W., Clayton D.G., Clarke M., Osborne D. Calcaneal ultrasound attenuation in an elderly population Measurement position and relationships with body size and past fractures . Osteoporos Int. 10:1999;316-324.
    • (1999) Osteoporos Int , vol.10 , pp. 316-324
    • Donaldson, M.M.K.1    McGrother, W.2    Clayton, D.G.3    Clarke, M.4    Osborne, D.5
  • 4
    • 0035074885 scopus 로고    scopus 로고
    • DXA of the hip and heel ultrasound but not densitometry of the fingers can discriminate female hip fracture patients from controls: A comparison between four different methods
    • Ekman A., Michaelson K., Petren-Mallmin M., Ljunghall S., Mallmin H. DXA of the hip and heel ultrasound but not densitometry of the fingers can discriminate female hip fracture patients from controls A comparison between four different methods . Osteoporos Int. 12:2001;185-191.
    • (2001) Osteoporos Int , vol.12 , pp. 185-191
    • Ekman, A.1    Michaelson, K.2    Petren-Mallmin, M.3    Ljunghall, S.4    Mallmin, H.5
  • 5
    • 0033400509 scopus 로고    scopus 로고
    • Contact quantitative ultrasound: An evaluation of precision, fracture discrimination, age-related bone loss and applicability of the WHO criteria
    • Frost M.L., Blake G.M., Fogelman I. Contact quantitative ultrasound An evaluation of precision, fracture discrimination, age-related bone loss and applicability of the WHO criteria . Osteoporos Int. 10:1999;441-449.
    • (1999) Osteoporos Int , vol.10 , pp. 441-449
    • Frost, M.L.1    Blake, G.M.2    Fogelman, I.3
  • 6
    • 0028936846 scopus 로고
    • Broadband ultrasound attenuation in the diagnosis of osteoporosis: Correlation with osteodensitometry and fracture
    • Funke M., Kopka L., Vosshenrich R., et al. Broadband ultrasound attenuation in the diagnosis of osteoporosis Correlation with osteodensitometry and fracture . Radiology. 194:1995;77-81.
    • (1995) Radiology , vol.194 , pp. 77-81
    • Funke, M.1    Kopka, L.2    Vosshenrich, R.3
  • 7
    • 0029112340 scopus 로고
    • Accurate assessment of precision errors: How to measure the reproducibility of bone denstitometry techniques
    • Gluer C.C., Blake G., Lu Y., et al. Accurate assessment of precision errors How to measure the reproducibility of bone denstitometry techniques . Osteoporos Int. 4:1995;262-270.
    • (1995) Osteoporos Int , vol.4 , pp. 262-270
    • Gluer, C.C.1    Blake, G.2    Lu, Y.3
  • 8
    • 0031846743 scopus 로고    scopus 로고
    • Simultaneous densitometry and quantitative bone sonography in the estimation of osteoporotic fracture risk
    • Gnudi S., Gualtieri G., Malavolta N. Simultaneous densitometry and quantitative bone sonography in the estimation of osteoporotic fracture risk. Br J Radiol. 71:1998;625-629.
    • (1998) Br J Radiol , vol.71 , pp. 625-629
    • Gnudi, S.1    Gualtieri, G.2    Malavolta, N.3
  • 9
    • 0030932953 scopus 로고    scopus 로고
    • The epidemiology of quantitative ultrasound: A review of the relationships with bone mass, osteoporosis and fracture risk
    • Gregg E.W., Kriska A.M., Salamone L.M., et al. The epidemiology of quantitative ultrasound A review of the relationships with bone mass, osteoporosis and fracture risk . Osteoporos Int. 7:1997;89-99.
    • (1997) Osteoporos Int , vol.7 , pp. 89-99
    • Gregg, E.W.1    Kriska, A.M.2    Salamone, L.M.3
  • 11
    • 0033043497 scopus 로고    scopus 로고
    • Stiffness index identifies patients with osteoporotic fractures better than ultrasound velocity or attenuation alone
    • Hadji P., Hars O., Wuster C.h, et al. Stiffness index identifies patients with osteoporotic fractures better than ultrasound velocity or attenuation alone. Maturitas. 31:1999;221-226.
    • (1999) Maturitas , vol.31 , pp. 221-226
    • Hadji, P.1    Hars, O.2    Wuster, Ch.3
  • 12
    • 0020524559 scopus 로고
    • A method of comparing the areas under the receiver operating characteristic curves derived from the same cases
    • Hanley J.A., McNeil B.J. A method of comparing the areas under the receiver operating characteristic curves derived from the same cases. Radiology. 148:1983;839-843.
    • (1983) Radiology , vol.148 , pp. 839-843
    • Hanley, J.A.1    McNeil, B.J.2
  • 13
    • 16044362010 scopus 로고    scopus 로고
    • Ultrasographic heel measurements to predict hip fracture in elderly women: The EPIDOS prospective study
    • Hans D., Dargent-Molina P., Schott A.M., et al. Ultrasographic heel measurements to predict hip fracture in elderly women The EPIDOS prospective study . Lancet. 348:1996;511-514.
    • (1996) Lancet , vol.348 , pp. 511-514
    • Hans, D.1    Dargent-Molina, P.2    Schott, A.M.3
  • 14
    • 0003486803 scopus 로고
    • Oxford: Blackwell
    • Kanis J.A. Osteoporosis. 1994;1-21 Blackwell, Oxford.
    • (1994) Osteoporosis , pp. 1-21
    • Kanis, J.A.1
  • 16
    • 0029986509 scopus 로고    scopus 로고
    • Meta-analysis of how well measures of bone mineral density predict occurence of osteoporotic fractures
    • Marshall D., Johnell O., Wedel H. Meta-analysis of how well measures of bone mineral density predict occurence of osteoporotic fractures. Br Med J. 312:1996;1254-1259.
    • (1996) Br Med J , vol.312 , pp. 1254-1259
    • Marshall, D.1    Johnell, O.2    Wedel, H.3
  • 17
    • 0031040692 scopus 로고    scopus 로고
    • The role for ultrasound in the assessment of osteoporosis: A review
    • Njeh C.F., Boivin C.M., Langton C.M. The role for ultrasound in the assessment of osteoporosis A review . Osteoporos Int. 7:1997;7-22.
    • (1997) Osteoporos Int , vol.7 , pp. 7-22
    • Njeh, C.F.1    Boivin, C.M.2    Langton, C.M.3
  • 18
    • 0032766025 scopus 로고    scopus 로고
    • Ultrasound measurements for the prediction of osteoporotic fractures in elderly people
    • Pluijm S.M.F., Graafmans W.C., Bouter L.M., Lips P. Ultrasound measurements for the prediction of osteoporotic fractures in elderly people. Osteoporos Int. 9:1999;550-556.
    • (1999) Osteoporos Int , vol.9 , pp. 550-556
    • Pluijm, S.M.F.1    Graafmans, W.C.2    Bouter, L.M.3    Lips, P.4
  • 19
    • 0031960205 scopus 로고    scopus 로고
    • Bone status assessed by quantitative ultrasound in healthy postmenopausal Polish women: Normative data
    • Pluskiewicz W. Bone status assessed by quantitative ultrasound in healthy postmenopausal Polish women Normative data . Clin Rheumatol. 17:1998;40-43.
    • (1998) Clin Rheumatol , vol.17 , pp. 40-43
    • Pluskiewicz, W.1
  • 20
    • 0031658196 scopus 로고    scopus 로고
    • Ultrasound measurement of proximal phalanges in a normal Polish female population
    • Pluskiewicz W., Drozdzowska B. Ultrasound measurement of proximal phalanges in a normal Polish female population. Osteoporos Int. 8:1998;349-354.
    • (1998) Osteoporos Int , vol.8 , pp. 349-354
    • Pluskiewicz, W.1    Drozdzowska, B.2
  • 21
    • 0032934089 scopus 로고    scopus 로고
    • Ultrasonic measurement of the calcaneus in Polish normal and osteoporotic women and men
    • Pluskiewicz W., Drozdzowska B. Ultrasonic measurement of the calcaneus in Polish normal and osteoporotic women and men. Bone. 24:1999;611-617.
    • (1999) Bone , vol.24 , pp. 611-617
    • Pluskiewicz, W.1    Drozdzowska, B.2
  • 22
    • 0032842682 scopus 로고    scopus 로고
    • Ultrasound measurements at the calcaneus in men: Differences between healthy and fractured persons and the influence of age and anthropometric features on ultrasound parameters
    • Pluskiewicz W., Drozdzowska B. Ultrasound measurements at the calcaneus in men Differences between healthy and fractured persons and the influence of age and anthropometric features on ultrasound parameters . Osteoporos Int. 10:1999;47-51.
    • (1999) Osteoporos Int , vol.10 , pp. 47-51
    • Pluskiewicz, W.1    Drozdzowska, B.2
  • 23
    • 0025032044 scopus 로고
    • Prediction of hip fracture in elderly women: A prospective study
    • Porter R.W., Miller C.G., Grainger D., Palmer S.B. Prediction of hip fracture in elderly women A prospective study . Br Med J. 301:1990;638-641.
    • (1990) Br Med J , vol.301 , pp. 638-641
    • Porter, R.W.1    Miller, C.G.2    Grainger, D.3    Palmer, S.B.4
  • 24
    • 0029123721 scopus 로고
    • Predicting vertebral deformity using bone densitometry at various skeletal sites and calcaneus ultrasound
    • Ross P., Huang C., Davis J., et al. Predicting vertebral deformity using bone densitometry at various skeletal sites and calcaneus ultrasound. Bone. 16:1995;325-332.
    • (1995) Bone , vol.16 , pp. 325-332
    • Ross, P.1    Huang, C.2    Davis, J.3
  • 25
    • 0028911460 scopus 로고
    • Ultrasound discriminates patients with hip fracture equally well as dual energy X-ray densitometry and independently of bone mineral density
    • Schott A.M., Weill-Engerer S., Hans D., et al. Ultrasound discriminates patients with hip fracture equally well as dual energy X-ray densitometry and independently of bone mineral density. J Bone Miner Res. 10:1995;243-249.
    • (1995) J Bone Miner Res , vol.10 , pp. 243-249
    • Schott, A.M.1    Weill-Engerer, S.2    Hans, D.3
  • 26
    • 0028943810 scopus 로고
    • The patient with fracture: The risk of subsequent fractures
    • Silman A.J. The patient with fracture The risk of subsequent fractures . Am J Med. 98:(Suppl. 2A):1995;12S-16S.
    • (1995) Am J Med , vol.98 , Issue.SUPPL. 2A
    • Silman, A.J.1
  • 27
    • 0028224218 scopus 로고
    • Broadband ultrasound attenuation and dual-energy X-ray absorptiometry in patients with hip fractures: Which technique discriminates fracture risk
    • Stewart A., Reid D.M., Porter R.W. Broadband ultrasound attenuation and dual-energy X-ray absorptiometry in patients with hip fractures Which technique discriminates fracture risk . Calcif Tissue Int. 54:1994;466-469.
    • (1994) Calcif Tissue Int , vol.54 , pp. 466-469
    • Stewart, A.1    Reid, D.M.2    Porter, R.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.