Volumn 35, Issue 11, 2002, Pages 1395-1406

Measuring higher order optical aberrations of the human eye: Techniques and applications

Author keywords

Corneal topography; Optical aberrations; Refractive surgery; Zernike polynomials

Indexed keywords

ARTICLE; ARTIFICIAL ORGAN; ASTIGMATISM; CALIBRATION; COMA; COMPUTER PROGRAM; CORNEA SURGERY; DECOMPOSITION; DEVICE; EYE REFRACTION; HUMAN; HYPERMETROPIA; INSTRUMENT; LIGHT; MATHEMATICAL ANALYSIS; MYOPIA; OPHTHALMOLOGY; OPTICAL INSTRUMENTATION; OPTICS; RETINA; SENSOR; TECHNIQUE; VISUAL DISORDER;

EID: 0036864469     PISSN: 0100879X     EISSN: 1414431X     Source Type: Journal    
DOI: 10.1590/S0100-879X2002001100019     Document Type: Article
Times cited : (23)

References (34)
  • 1
    • 0028469062 scopus 로고
    • Objective measurement of wave aberrations of the human eye with the use of a Hartmann-Shack wave-front sensor
    • Liang J, Grimm B, Goelz S & Bille JF (1994). Objective measurement of wave aberrations of the human eye with the use of a Hartmann-Shack wave-front sensor. Journal of the Optical Society of America, 11: 1949-1957.
    • (1994) Journal of the Optical Society of America , vol.11 , pp. 1949-1957
    • Liang, J.1    Grimm, B.2    Goelz, S.3    Bille, J.F.4
  • 2
    • 0033782273 scopus 로고    scopus 로고
    • Principles of Hartmann-Shack aberrometry
    • Thibos LN (2000). Principles of Hartmann-Shack aberrometry. Journal of Refractive Surgery, 16: 540-545.
    • (2000) Journal of Refractive Surgery , vol.16 , pp. 540-545
    • Thibos, L.N.1
  • 3
    • 0012077749 scopus 로고
    • Oculus, sive fundamentum opticum
    • Innspruk, Austria
    • Scheiner C (1619). Oculus, sive fundamentum opticum. Innspruk, Austria.
    • (1619)
    • Scheiner, C.1
  • 5
    • 0000225799 scopus 로고
    • Use of crossed cylinder lens in photographic lens evaluation
    • Howland B (1960). Use of crossed cylinder lens in photographic lens evaluation. Applied Optics, 7: 1587-1588.
    • (1960) Applied Optics , vol.7 , pp. 1587-1588
    • Howland, B.1
  • 9
    • 0012097593 scopus 로고
    • Eye refractive power measuring apparatus
    • US Patent No. 4755041, July 5
    • Shikawa YY (1988). Eye refractive power measuring apparatus. US Patent No. 4755041, July 5.
    • (1988)
    • Shikawa, Y.Y.1
  • 10
    • 0012104911 scopus 로고
    • Novo instrumento de exploração da córnea
    • Plácido A (1880). Novo instrumento de exploração da córnea. Periodico d'Oftalmologia Pratica, 5: 27-30.
    • (1880) Periodico D'Oftalmologia Pratica , vol.5 , pp. 27-30
    • Plácido, A.1
  • 11
  • 13
    • 85036690587 scopus 로고    scopus 로고
    • Detecção de bordas de imagens refletidas pela superfície anterior da cornea
    • III Fórum Nacional de Ciência e Tecnologia em Saúde, Campos de Jordão, SP, Brazil
    • Carvalho LA, Silva EP, Santos LER, Tonissi SA, Romão AC & Castro JC (1996). Detecção de bordas de imagens refletidas pela superfície anterior da cornea. III Fórum Nacional de Ciência e Tecnologia em Saúde, Campos de Jordão, SP, Brazil.
    • (1996)
    • Carvalho, L.A.1    Silva, E.P.2    Santos, L.E.R.3    Tonissi, S.A.4    Romão, A.C.5    Castro, J.C.6
  • 15
    • 0029394985 scopus 로고
    • A spline surface algorithm for reconstruction of corneal topography from a videokeratographic reflection pattern
    • Halstead MA, Barsky BA, Klein SA & Mandell RB (1995). A spline surface algorithm for reconstruction of corneal topography from a videokeratographic reflection pattern. Optometry and Vision Science, 72: 821-827.
    • (1995) Optometry and Vision Science , vol.72 , pp. 821-827
    • Halstead, M.A.1    Barsky, B.A.2    Klein, S.A.3    Mandell, R.B.4
  • 17
    • 0032869107 scopus 로고    scopus 로고
    • KISA% index: A quantitative videokeratography algorithm embodying minimal topographic criteria for diagnosing keratoconus
    • Rabinovitz YS & Rasheed K (1999). KISA% index: A quantitative videokeratography algorithm embodying minimal topographic criteria for diagnosing keratoconus. Journal of Cataract and Refractive Surgery, 25: 1327-1335.
    • (1999) Journal of Cataract and Refractive Surgery , vol.25 , pp. 1327-1335
    • Rabinovitz, Y.S.1    Rasheed, K.2
  • 20
    • 1542666947 scopus 로고    scopus 로고
    • Wave-front measurements of the human eye using the Hartmann-Shack sensor and current state-of-the-art technology for excimer laser refractive surgery. Lasik and beyond Lasik
    • Chapter 31. Boyd BF (Editor), Pergamon Press, Oxford, England
    • Carvalho Luis Alberto V, Castro JC, Chamon W, Schor P & Carvalho Luis Antonio V (2001). Wave-front measurements of the human eye using the Hartmann-Shack sensor and current state-of-the-art technology for excimer laser refractive surgery. Lasik and beyond Lasik. Chapter 31. In: Boyd BF (Editor), Highlights of Ophthalmology. Pergamon Press, Oxford, England.
    • (2001) Highlights of Ophthalmology
    • Carvalho Luis Alberto, V.1    Castro, J.C.2    Chamon, W.3    Schor, P.4    Carvalho Luis Antonio, V.5
  • 23
    • 0001784320 scopus 로고
    • Bemerkungen über den Bau und die Justierung von Spektrographen
    • Hartmann J (1900). Bemerkungen über den Bau und die Justierung von Spektrographen. Zeitschrift für Instrumentenkunde, 20: 47.
    • (1900) Zeitschrift Für Instrumentenkunde , vol.20 , pp. 47
    • Hartmann, J.1
  • 25
    • 85036722659 scopus 로고    scopus 로고
    • Desenvolvimento de um sistema para medicas de aberrações ópticas do olho humano usando a técnica de Hartmann-Shack
    • XXIV Encontro Nacional de Física da Matéria Condensada, Óptica (Lasers e Instrumentação, Óptica), São Lourenço, MG, Brazil, May 15-19
    • Junior FS, Yasuoka F, Santos J, Carvalho LA & Castro JC (2001). Desenvolvimento de um sistema para medicas de aberrações ópticas do olho humano usando a técnica de Hartmann-Shack. XXIV Encontro Nacional de Física da Matéria Condensada, Óptica (Lasers e Instrumentação, Óptica), São Lourenço, MG, Brazil, May 15-19, 457.
    • (2001) , pp. 457
    • Junior, F.S.1    Yasuoka, F.2    Santos, J.3    Carvalho, L.A.4    Castro, J.C.5
  • 26
    • 0004230728 scopus 로고
    • Introduction to wave-front sensors
    • O'Shea DC (Editor), TT 18. SPIE Press, New York, NY, USA
    • Geary JM (1995). Introduction to wave-front sensors. In: O'Shea DC (Editor), Tutorial Texts in Optical Engineering. Vol. TT 18. SPIE Press, New York, NY, USA.
    • (1995) Tutorial Texts in Optical Engineering
    • Geary, J.M.1
  • 27
    • 0003972070 scopus 로고
    • Cambridge University Press, UK (ISBN: 0521642221, 71h edn., October 1999)
    • Born M (1975). Principles of Optics. Cambridge University Press, UK (ISBN: 0521642221, 71h edn., October 1999), 464-466.
    • (1975) Principles of Optics , pp. 464-466
    • Born, M.1
  • 28
    • 0003458535 scopus 로고
    • 1st English Edition. Interscience Publishers, New York, NY, USA
    • Cournant R & Hilbert D (1953). Methods of Mathematical Physics. Vol. 1. 1st English Edition. Interscience Publishers, New York, NY, USA.
    • (1953) Methods of Mathematical Physics , vol.1
    • Cournant, R.1    Hilbert, D.2
  • 29
    • 0033782335 scopus 로고    scopus 로고
    • VSIA Standards Taskforce members. Report from the VSIA taskforce on standards for reporting optical aberrations of the eye
    • Thibos LN, Applegate RA, Schwiegerling JT & Webb R (2000). VSIA Standards Taskforce members. Report from the VSIA taskforce on standards for reporting optical aberrations of the eye. Journal of Refractive Surgery, 16: S654-S655.
    • (2000) Journal of Refractive Surgery , vol.16
    • Thibos, L.N.1    Applegate, R.A.2    Schwiegerling, J.T.3    Webb, R.4
  • 31
    • 85036715703 scopus 로고    scopus 로고
    • Sensor Hartmann-Shack para uso oftalmológico
    • XXIV Encontro Nacional de Física da Matéria Condensada, Óptica (Lasers e Instrumentação, Óptica), São Lourenço, MG, Brazil, May 15-19
    • Santos JB, Scannavino Jr FA, Carvalho LAV, Filho RL & Castro JCN (2001). Sensor Hartmann-Shack para uso oftalmológico. XXIV Encontro Nacional de Física da Matéria Condensada, Óptica (Lasers e Instrumentação, Óptica), São Lourenço, MG, Brazil, May 15-19, 457.
    • (2001) , pp. 457
    • Santos, J.B.1    Scannavino F.A., Jr.2    Carvalho, L.A.V.3    Filho, R.L.4    Castro, J.C.N.5
  • 32
    • 0038306078 scopus 로고    scopus 로고
    • Instrumento eletro-óptico para medidas automatizadas da acomodação do olho humano (in vivo) durante medidas refrativas
    • XXIV Encontro Nacional de Física da Matéria Condensada, Óptica (Lasers e Instrumentação Óptica), São Lourenço, MG, Brazil, May 15-19
    • Scannavino Jr FA, Filho RL, Santos JB, Carvalho LAV & Castro JCN (2001). Instrumento eletro-óptico para medidas automatizadas da acomodação do olho humano (in vivo) durante medidas refrativas. XXIV Encontro Nacional de Física da Matéria Condensada, Óptica (Lasers e Instrumentação Óptica), São Lourenço, MG, Brazil, May 15-19, 458.
    • (2001) , pp. 458
    • Scannavino F.A., Jr.1    Filho, R.L.2    Santos, J.B.3    Carvalho, L.A.V.4    Castro, J.C.N.5
  • 34
    • 0032159824 scopus 로고    scopus 로고
    • Optimal corneal ablation for eyes with arbitrary Hartmann-Shack aberrations
    • Klein SA (1998). Optimal corneal ablation for eyes with arbitrary Hartmann-Shack aberrations. Journal of the Optical Society of America, 15: 2580-2588.
    • (1998) Journal of the Optical Society of America , vol.15 , pp. 2580-2588
    • Klein, S.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.