메뉴 건너뛰기




Volumn 25, Issue 11, 2002, Pages 1624-1627

Compatibility of automatic threshold tracking pacemakers with previously implanted pacing leads in children

Author keywords

Autocapture; Children; Nonrecommended leads; Threshold tracking

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; ARTIFICIAL HEART PACEMAKER; AUTOMATION; BIOMEDICAL TECHNOLOGY ASSESSMENT; CHILD; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; HEART ARRHYTHMIA; HUMAN; MALE; PACEMAKER ELECTRODE; ELECTROPHYSIOLOGY; EQUIPMENT DESIGN; FOLLOW UP;

EID: 0036855650     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1460-9592.2002.01624.x     Document Type: Article
Times cited : (12)

References (8)
  • 1
    • 0029858963 scopus 로고    scopus 로고
    • Italian experience with autocapture in conjunction with a membrane lead
    • Sermasi S, Marconi M, Libero L, et al. Italian experience with autocapture in conjunction with a membrane lead. PACE 1996; 19:1799-1804.
    • (1996) PACE , vol.19 , pp. 1799-1804
    • Sermasi, S.1    Marconi, M.2    Libero, L.3
  • 2
    • 0000244285 scopus 로고    scopus 로고
    • Initial experience with threshold tracking pacemakers in children
    • abstract
    • Celiker A, Kucukosmanoglu O, Alehan D, et al. Initial experience with threshold tracking pacemakers in children. (abstract) PACE 1997; 20:2137.
    • (1997) PACE , vol.20 , pp. 2137
    • Celiker, A.1    Kucukosmanoglu, O.2    Alehan, D.3
  • 3
    • 0031826755 scopus 로고    scopus 로고
    • Automatic adjustment of pacemaker stimulation output correlated with continuously monitored capture thresholds: A multicenter study
    • Clarke M, Liu B, Schüller H, et al. Automatic adjustment of pacemaker stimulation output correlated with continuously monitored capture thresholds: A multicenter study. PACE 1998; 21:1567-1575.
    • (1998) PACE , vol.21 , pp. 1567-1575
    • Clarke, M.1    Liu, B.2    Schüller, H.3
  • 4
    • 0034046965 scopus 로고    scopus 로고
    • A cardiac evoked response algorithm providing threshold tracking: A North American multicenter study
    • Lau C, Cameron DA, Nishimura SC, et al. A cardiac evoked response algorithm providing threshold tracking: A North American multicenter study. PACE 2000; 23:953-959.
    • (2000) PACE , vol.23 , pp. 953-959
    • Lau, C.1    Cameron, D.A.2    Nishimura, S.C.3
  • 5
    • 0034101826 scopus 로고    scopus 로고
    • Automatic threshold tracking activation without the intraoperative evaluation of the evoked response amplitude
    • Schuchert A, Ventura R, Meinertz T. Automatic threshold tracking activation without the intraoperative evaluation of the evoked response amplitude. PACE 2000; 23:321-324.
    • (2000) PACE , vol.23 , pp. 321-324
    • Schuchert, A.1    Ventura, R.2    Meinertz, T.3
  • 7
    • 0026800758 scopus 로고
    • Lead extraction: Indications and techniques
    • Byrd CL, Schwarts SJ, Hedin N. Lead extraction: Indications and techniques. Cardiol Clin 1992; 10:735-748.
    • (1992) Cardiol Clin , vol.10 , pp. 735-748
    • Byrd, C.L.1    Schwarts, S.J.2    Hedin, N.3
  • 8
    • 0034494557 scopus 로고    scopus 로고
    • Improved differentiation of the ventricular evoked response from polarization by modification of the pacemaker impulse
    • Provenier F, Germonpre E, De Wagter X. Improved differentiation of the ventricular evoked response from polarization by modification of the pacemaker impulse. PACE 2000; 23:2073-2077.
    • (2000) PACE , vol.23 , pp. 2073-2077
    • Provenier, F.1    Germonpre, E.2    De Wagter, X.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.