메뉴 건너뛰기




Volumn 13, Issue 4, 2002, Pages 344-349

Strategies for reducing ultra-high molecular weight polyethylene wear and osteolysis in total knee arthroplasty

Author keywords

[No Author keywords available]

Indexed keywords

CHROMIUM; COBALT; POLYETHYLENE; ZIRCONIUM OXIDE;

EID: 0036822369     PISSN: 10454527     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (5)

References (46)
  • 1
    • 0026625750 scopus 로고
    • Survivorship analysis in total condylar knee arthroplasty. A statistical review
    • Nelissen RG, Brand R, Rozing PM: Survivorship analysis in total condylar knee arthroplasty. A statistical review. J Bone Joint Surg Am 74:383-389, 1992
    • (1992) J. Bone Joint Surg. Am. , vol.74 , pp. 383-389
    • Nelissen, R.G.1    Brand, R.2    Rozing, P.M.3
  • 2
    • 0023868757 scopus 로고
    • Survivorship analysis and results of total condylar knee arthroplasty. Eight- to 11-year follow-up period
    • Ranawat CS, Boachie-Adjei O: Survivorship analysis and results of total condylar knee arthroplasty. Eight- to 11-year follow-up period. Clin Orthop 226:6-13, 1988
    • (1988) Clin. Orthop. , vol.226 , pp. 6-13
    • Ranawat, C.S.1    Boachie-Adjei, O.2
  • 3
    • 0030983899 scopus 로고    scopus 로고
    • Total knee replacement in young, active patients. Long-term follow-up and functional outcome
    • Diduch DR, Insall JN, Scott WN, et al: Total knee replacement in young, active patients. Long-term follow-up and functional outcome. J Bone Joint Surg Am 79:575-582, 1997
    • (1997) J. Bone Joint Surg. Am. , vol.79 , pp. 575-582
    • Diduch, D.R.1    Insall, J.N.2    Scott, W.N.3
  • 4
    • 0026803119 scopus 로고
    • Posterior stabilized prosthesis. Results after follow-up of nine to twelve years
    • Stern SH, Insall JN: Posterior stabilized prosthesis. Results after follow-up of nine to twelve years. J Bone Joint Surg Am 74:980-986, 1992
    • (1992) J. Bone Joint Surg. Am. , vol.74 , pp. 980-986
    • Stern, S.H.1    Insall, J.N.2
  • 5
    • 0020576705 scopus 로고
    • The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis
    • Goldring SR, Schiller AL, Roelke M, et al: The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis. J Bone Joint Surg Am 65:575-584, 1983
    • (1983) J. Bone Joint Surg. Am. , vol.65 , pp. 575-584
    • Goldring, S.R.1    Schiller, A.L.2    Roelke, M.3
  • 6
    • 0022527759 scopus 로고
    • Localized osteolysis in stable, non-septic total hip replacement
    • Jasty M, Floyd WE III, Schiller AL, et al: Localized osteolysis in stable, non-septic total hip replacement. J Bone Joint Surg Am 68:912-919, 1986
    • (1986) J. Bone Joint Surg. Am. , vol.68 , pp. 912-919
    • Jasty, M.1    Floyd W.E. III2    Schiller, A.L.3
  • 7
    • 0032913473 scopus 로고    scopus 로고
    • Fracture of the femoral component associated with polyethylene wear and osteolysis after total knee arthroplasty
    • Huang CH, Yang CY, Cheng CK: Fracture of the femoral component associated with polyethylene wear and osteolysis after total knee arthroplasty. J Arthroplasty 14:375-379, 1999
    • (1999) J. Arthroplasty , vol.14 , pp. 375-379
    • Huang, C.H.1    Yang, C.Y.2    Cheng, C.K.3
  • 8
    • 0027954306 scopus 로고
    • Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces
    • Feng EL, Stulberg SD, Wixson RL: Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces. Clin Orthop 299:60-71, 1994
    • (1994) Clin. Orthop. , vol.299 , pp. 60-71
    • Feng, E.L.1    Stulberg, S.D.2    Wixson, R.L.3
  • 9
    • 0035113426 scopus 로고    scopus 로고
    • Failed cementless total knee arthroplasty presenting as osteolysis of the fibular head
    • Rodriguez RJ, Barrack RL: Failed cementless total knee arthroplasty presenting as osteolysis of the fibular head. J Arthroplasty 16:239-242, 2001
    • (2001) J. Arthroplasty , vol.16 , pp. 239-242
    • Rodriguez, R.J.1    Barrack, R.L.2
  • 10
    • 0032774199 scopus 로고    scopus 로고
    • The Insall-Burstein total knee replacement in osteoarthritis: A 10-year minimum follow-up
    • Aglietti P, Buzzi R, De Felice R, et al: The Insall-Burstein total knee replacement in osteoarthritis: A 10-year minimum follow-up. J Arthroplasty 14:560-565, 1999
    • (1999) J. Arthroplasty , vol.14 , pp. 560-565
    • Aglietti, P.1    Buzzi, R.2    De Felice, R.3
  • 11
    • 0021947881 scopus 로고
    • The anatomic total knee resurfacing arthroplasty
    • Townley CO: The anatomic total knee resurfacing arthroplasty. Clin Orthop 192:82-96, 1985
    • (1985) Clin. Orthop. , vol.192 , pp. 82-96
    • Townley, C.O.1
  • 12
    • 0028580091 scopus 로고
    • Osteolysis of the distal femur after total knee arthroplasty
    • Cadambi A, Engh GA, Dwyer KA, et al: Osteolysis of the distal femur after total knee arthroplasty. J Arthroplasty 9:579-594, 1994
    • (1994) J. Arthroplasty , vol.9 , pp. 579-594
    • Cadambi, A.1    Engh, G.A.2    Dwyer, K.A.3
  • 13
    • 0022389660 scopus 로고
    • Granulomatous reaction and cystic bony destruction associated with high wear rate in a total knee prosthesis
    • Dannenmaier WC, Haynes DW, Nelson CL: Granulomatous reaction and cystic bony destruction associated with high wear rate in a total knee prosthesis. Clin Orthop 198:224-230, 1985
    • (1985) Clin. Orthop. , vol.198 , pp. 224-230
    • Dannenmaier, W.C.1    Haynes, D.W.2    Nelson, C.L.3
  • 14
    • 0026569950 scopus 로고
    • Aggressive granulomatosis from polyethylene failure in an uncemented knee replacement
    • Nolan JF, Bucknill TM: Aggressive granulomatosis from polyethylene failure in an uncemented knee replacement. J Bone Joint Surg Br 74:23-24, 1992
    • (1992) J. Bone Joint Surg. Br. , vol.74 , pp. 23-24
    • Nolan, J.F.1    Bucknill, T.M.2
  • 16
    • 0023007566 scopus 로고
    • The effect of conformity, thickness and material on stresses in ultra-high molecular weight components for total joint replacement
    • Bartel DL, Bicknell VL, Wright TM: The effect of conformity, thickness and material on stresses in ultra-high molecular weight components for total joint replacement. J Bone Joint Surg Am 68:1041-1051, 1986
    • (1986) J. Bone Joint Surg. Am. , vol.68 , pp. 1041-1051
    • Bartel, D.L.1    Bicknell, V.L.2    Wright, T.M.3
  • 17
    • 0035727965 scopus 로고    scopus 로고
    • The effect of contact area on wear in relation to fixed bearing and mobile bearing knee replacements
    • Sathasivam S, Walker PS, Campbell PA, et al: The effect of contact area on wear in relation to fixed bearing and mobile bearing knee replacements. J Biomed Mater Res 58:282-290, 2001
    • (2001) J. Biomed. Mater. Res. , vol.58 , pp. 282-290
    • Sathasivam, S.1    Walker, P.S.2    Campbell, P.A.3
  • 18
    • 0018934649 scopus 로고
    • The function of the primary ligaments of the knee in varus-valgus and axial rotation
    • Seering WP, Piziali RL, Nagel DA, et al: The function of the primary ligaments of the knee in varus-valgus and axial rotation. J Biomech 13:785-794, 1980
    • (1980) J. Biomech. , vol.13 , pp. 785-794
    • Seering, W.P.1    Piziali, R.L.2    Nagel, D.A.3
  • 19
    • 0034103783 scopus 로고    scopus 로고
    • Cemented rotating-platform total knee replacement: A nine to twelve-year followup study
    • Callaghan JJ, Squire M, Goetz D, et al: Cemented rotating-platform total knee replacement: A nine to twelve-year followup study. J Bone Joint Surg Am 82:705-711, 2000
    • (2000) J. Bone Joint Surg. Am. , vol.82 , pp. 705-711
    • Callaghan, J.J.1    Squire, M.2    Goetz, D.3
  • 20
    • 0034876674 scopus 로고    scopus 로고
    • Midterm results of mobile-bearing total knee arthroplasty in patients younger than 65 years
    • Sorrells RB, Stiehl JB, Voorhorst PE: Midterm results of mobile-bearing total knee arthroplasty in patients younger than 65 years. Clin Orthop 390:182-189, 2001
    • (2001) Clin. Orthop. , vol.390 , pp. 182-189
    • Sorrells, R.B.1    Stiehl, J.B.2    Voorhorst, P.E.3
  • 21
    • 0025086844 scopus 로고
    • Long-term survivorship analysis of cruciate-sparing versus cruciate-sacrificing knee prostheses using meniscal bearings
    • Buechel FF, Pappas MJ: Long-term survivorship analysis of cruciate-sparing versus cruciate-sacrificing knee prostheses using meniscal bearings. Clin Orthop 260:162-169, 1990
    • (1990) Clin. Orthop. , vol.260 , pp. 162-169
    • Buechel, F.F.1    Pappas, M.J.2
  • 22
    • 0025210147 scopus 로고
    • Dislocation/subluxation of meniscal bearing elements after new jersey low contact stress total knee arthroplasty
    • Bert JM: Dislocation/subluxation of meniscal bearing elements after new jersey low contact stress total knee arthroplasty. Clin Orthop 254:211-215, 1990
    • (1990) Clin. Orthop. , vol.254 , pp. 211-215
    • Bert, J.M.1
  • 23
    • 0030946950 scopus 로고    scopus 로고
    • Survivorship analysis of cementless meniscal-bearing total knee arthroplasty
    • Jordan LR, Olivo JL, Voorhorst PR: Survivorship analysis of cementless meniscal-bearing total knee arthroplasty. Clin Orthop 338:119-123, 1997
    • (1997) Clin. Orthop. , vol.338 , pp. 119-123
    • Jordan, L.R.1    Olivo, J.L.2    Voorhorst, P.R.3
  • 24
    • 0027324619 scopus 로고
    • Difficulties with bearing dislocation and breakage using a movable bearing total knee replacement system
    • Weaver JK, Derkash RS, Greenwald AS: Difficulties with bearing dislocation and breakage using a movable bearing total knee replacement system. Clin Orthop 290:244-252, 1993
    • (1993) Clin. Orthop. , vol.290 , pp. 244-252
    • Weaver, J.K.1    Derkash, R.S.2    Greenwald, A.S.3
  • 25
    • 0032417378 scopus 로고    scopus 로고
    • In vivo anteroposterior femorotibial translation of total knee arthroplasty: A multicenter analysis
    • Dennis DA, Komistek RD, Colwell CE, et al: In vivo anteroposterior femorotibial translation of total knee arthroplasty: A multicenter analysis. Clin Orthop 356:47-57, 1998
    • (1998) Clin. Orthop. , vol.356 , pp. 47-57
    • Dennis, D.A.1    Komistek, R.D.2    Colwell, C.E.3
  • 27
    • 0026727771 scopus 로고
    • Total knee arthroplasty in elderly patients: Comparison of tibial component designs
    • L'Insalata J, Insall J: Total knee arthroplasty in elderly patients: Comparison of tibial component designs. J Arthroplasty 7:261-266, 1992
    • (1992) J. Arthroplasty , vol.7 , pp. 261-266
    • L'Insalata, J.1    Insall, J.2
  • 28
    • 0019969676 scopus 로고
    • Performance of the tibial component in total knee replacement: Conventional and revision designs
    • Bartel D, Burstein A, Santavicca E, et al: Performance of the tibial component in total knee replacement: Conventional and revision designs. J Bone Joint Surg Am 64:1026-1031, 1982
    • (1982) J. Bone Joint Surg. Am. , vol.64 , pp. 1026-1031
    • Bartel, D.1    Burstein, A.2    Santavicca, E.3
  • 29
    • 0020052795 scopus 로고
    • Effects of tibial components on load transfer in the upper tibia
    • Reilly D, Walker P, Ben-Dov M, et al: Effects of tibial components on load transfer in the upper tibia. Clin Orthop 165:273-278, 1982
    • (1982) Clin. Orthop. , vol.165 , pp. 273-278
    • Reilly, D.1    Walker, P.2    Ben-Dov, M.3
  • 30
    • 0031457130 scopus 로고    scopus 로고
    • Tibia insert undersurface wear as a contributing source of polyethylene wear debris
    • Wasielewski RC, Parks N, Williams I, et al: Tibia insert undersurface wear as a contributing source of polyethylene wear debris. Clin Orthop 345:53-59, 1997
    • (1997) Clin. Orthop. , vol.345 , pp. 53-59
    • Wasielewski, R.C.1    Parks, N.2    Williams, I.3
  • 31
    • 0032201263 scopus 로고    scopus 로고
    • Modular tibial insert micromotion: A concern with contemporary knee implants
    • Parks N, Engh G, Topoleski T, et al: Modular tibial insert micromotion: A concern with contemporary knee implants. Clin Orthop 356:10-15, 1998
    • (1998) Clin. Orthop. , vol.356 , pp. 10-15
    • Parks, N.1    Engh, G.2    Topoleski, T.3
  • 32
    • 0033743948 scopus 로고    scopus 로고
    • Results of all-polyethylene tibial components as a cost-saving technique
    • Pomeroy D, Schaper L, Badenhousen W, et al: Results of all-polyethylene tibial components as a cost-saving technique. Clin Orthop 380:140-143, 2000
    • (2000) Clin. Orthop. , vol.380 , pp. 140-143
    • Pomeroy, D.1    Schaper, L.2    Badenhousen, W.3
  • 33
    • 0026356991 scopus 로고
    • Clinical comparison of all polyethylene and metal backed tibial components in total knee arthroplasty
    • Apel D, Tozzi J, Dorr L: Clinical comparison of all polyethylene and metal backed tibial components in total knee arthroplasty. Clin Orthop 273:243-252, 1991
    • (1991) Clin. Orthop. , vol.273 , pp. 243-252
    • Apel, D.1    Tozzi, J.2    Dorr, L.3
  • 34
    • 0027262160 scopus 로고
    • Comparison of metal-backed and all-polyethylene tibial components in cruciate condylar total knee arthroplasty
    • Rand J: Comparison of metal-backed and all-polyethylene tibial components in cruciate condylar total knee arthroplasty. J Arthroplasty 8:307-313, 1993
    • (1993) J. Arthroplasty , vol.8 , pp. 307-313
    • Rand, J.1
  • 35
    • 0033822908 scopus 로고    scopus 로고
    • Low-conforming all-polyethylene tibial component not inferior to metal-backed component in cemented total knee arthroplasty
    • Adalberth G, Nilsson K, Bystrom S, et al: Low-conforming all-polyethylene tibial component not inferior to metal-backed component in cemented total knee arthroplasty. J Arthroplasty 15:783-792, 2000
    • (2000) J. Arthroplasty , vol.15 , pp. 783-792
    • Adalberth, G.1    Nilsson, K.2    Bystrom, S.3
  • 36
    • 0032721715 scopus 로고    scopus 로고
    • Cemented all polyethylene tibial components in patients age 75 years and older
    • Pagnano M, Levy B, Berry D: Cemented all polyethylene tibial components in patients age 75 years and older. Clin Orthop 367:73-80, 1999
    • (1999) Clin. Orthop. , vol.367 , pp. 73-80
    • Pagnano, M.1    Levy, B.2    Berry, D.3
  • 37
    • 0033744681 scopus 로고    scopus 로고
    • A randomized comparison of all-polyethylene and metal-backed tibial components
    • Gioe T, Bowman K: A randomized comparison of all-polyethylene and metal-backed tibial components. Clin Orthop 380:108-115, 2000
    • (2000) Clin. Orthop. , vol.380 , pp. 108-115
    • Gioe, T.1    Bowman, K.2
  • 38
    • 0035163418 scopus 로고    scopus 로고
    • Metal-backed and all-polyethylene components in total knee arthroplasty
    • Rodriguez J, Baez N, Rasquinha V, et al: Metal-backed and all-polyethylene components in total knee arthroplasty. Clin Orthop 392:174-183, 2001
    • (2001) Clin. Orthop. , vol.392 , pp. 174-183
    • Rodriguez, J.1    Baez, N.2    Rasquinha, V.3
  • 39
    • 0034027601 scopus 로고    scopus 로고
    • Third-body war of cobalt-chromium-molybdenum implant alloys initiated by bone and polymethylmethacrylate particles
    • Que L, Topoleski L: Third-body war of cobalt-chromium-molybdenum implant alloys initiated by bone and polymethylmethacrylate particles. J Biomed Mater Res 50:322-330, 2000
    • (2000) J. Biomed. Mater. Res. , vol.50 , pp. 322-330
    • Que, L.1    Topoleski, L.2
  • 40
    • 0000702882 scopus 로고    scopus 로고
    • Scratches on condyles in normal functioning total knee arthroplasty
    • Levesque M, Livingston B, Jones W, et al: Scratches on condyles in normal functioning total knee arthroplasty. Trans Orthop Res Soc 23:247, 1998
    • (1998) Trans. Orthop. Res. Soc. , vol.23 , pp. 247
    • Levesque, M.1    Livingston, B.2    Jones, W.3
  • 41
    • 0000858910 scopus 로고    scopus 로고
    • Abrasive wear simulation in total knee arthroplasty
    • Ries M, Banks S, Sauer W, et al: Abrasive wear simulation in total knee arthroplasty. Trans Orthop Res Soc 24:853, 1999
    • (1999) Trans. Orthop. Res. Soc. , vol.24 , pp. 853
    • Ries, M.1    Banks, S.2    Sauer, W.3
  • 42
    • 0023098131 scopus 로고
    • The role of counterface imperfections in the wear of polyethylene
    • Dowson D, Taheri S, Wallbridge N: The role of counterface imperfections in the wear of polyethylene. Wear 119:277, 1987
    • (1987) Wear , vol.119 , pp. 277
    • Dowson, D.1    Taheri, S.2    Wallbridge, N.3
  • 43
    • 0002822436 scopus 로고    scopus 로고
    • Experimental and theoretical predictions of wear particle generation in UHMWPE due to microscopic femoral counterface asperities
    • McNie C, Barton D, Ingham E, et al: Experimental and theoretical predictions of wear particle generation in UHMWPE due to microscopic femoral counterface asperities. Trans Orthop Res Soc 23:75, 1998
    • (1998) Trans. Orthop. Res. Soc. , vol.23 , pp. 75
    • McNie, C.1    Barton, D.2    Ingham, E.3
  • 44
    • 0035175965 scopus 로고    scopus 로고
    • Wear performance of ultra-high molecular weight polyethylene on oxidized zirconium total knee femoral components
    • Spector M, Ries M, Bourne R, et al: Wear performance of ultra-high molecular weight polyethylene on oxidized zirconium total knee femoral components. J Bone Joint Surg Am 83:80-86, 2001 (suppl)
    • (2001) J. Bone Joint Surg. Am. , vol.83 , Issue.SUPPL. , pp. 80-86
    • Spector, M.1    Ries, M.2    Bourne, R.3
  • 45
    • 0028594009 scopus 로고
    • Simulated knee wear with cobalt chromium and oxidized zirconium knee femoral components
    • White S, Whiteside L, McCarthy D, et al: Simulated knee wear with cobalt chromium and oxidized zirconium knee femoral components. Clin Orthop 309:176-184, 1994
    • (1994) Clin. Orthop. , vol.309 , pp. 176-184
    • White, S.1    Whiteside, L.2    McCarthy, D.3
  • 46
    • 0035108321 scopus 로고    scopus 로고
    • Metal sensitivity in patients with orthopaedic implants
    • Hallab N, Merritt K, Jacobs J: Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am 83:428-436, 2001
    • (2001) J. Bone Joint Surg. Am. , vol.83 , pp. 428-436
    • Hallab, N.1    Merritt, K.2    Jacobs, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.