메뉴 건너뛰기




Volumn 20, Issue 10, 2002, Pages 1981-1986

Variable day/night bias in 24-h non-invasive finger pressure against intrabrachial artery pressure is removed by waveform filtering and level correction

Author keywords

Bias; Blood pressure; Brachial; Day night; Dip; Finger; Pressure difference

Indexed keywords

ADULT; ARTICLE; BLOOD PRESSURE MEASUREMENT; BLOOD PRESSURE MONITORING; BRACHIAL ARTERY; CIRCADIAN RHYTHM; CLINICAL ARTICLE; CONTROLLED STUDY; CORRELATION ANALYSIS; DIAGNOSTIC PROCEDURE; DIASTOLIC BLOOD PRESSURE; FEMALE; HUMAN; MALE; PRIORITY JOURNAL; STATISTICAL ANALYSIS; SYSTOLIC BLOOD PRESSURE; WAVEFORM; BLOOD PRESSURE; COMPARATIVE STUDY; DIASTOLE; EPIDEMIOLOGY; EVALUATION; FINGER; HYPERTENSION; MIDDLE AGED; PATHOPHYSIOLOGY; PHYSIOLOGY; SYSTOLE; VASCULARIZATION;

EID: 0036808295     PISSN: 02636352     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004872-200210000-00017     Document Type: Article
Times cited : (29)

References (13)
  • 1
    • 0031051049 scopus 로고    scopus 로고
    • Models of brachial to finger pulse wave distortion and pressure decrement
    • Gizdulich P, Prentza A, Wesseling KH. Models of brachial to finger pulse wave distortion and pressure decrement. Cardiovasc Res 1997; 33:698-705.
    • (1997) Cardiovasc Res , vol.33 , pp. 698-705
    • Gizdulich, P.1    Prentza, A.2    Wesseling, K.H.3
  • 4
    • 0026756113 scopus 로고
    • Effects of graded vasoconstriction upon the measurement of finger arterial pressure
    • Imholz BPM, Parati G, Mancia G, Wesseling KH. Effects of graded vasoconstriction upon the measurement of finger arterial pressure. J Hypertens 1992; 10:979-984.
    • (1992) J Hypertens , vol.10 , pp. 979-984
    • Imholz, B.P.M.1    Parati, G.2    Mancia, G.3    Wesseling, K.H.4
  • 8
    • 0014301032 scopus 로고
    • Disparities between aortic and peripheral pulse pressures induced by upright exercise and vasomotor changes in man
    • Rowel LB, Brengelmann GL, Blackmon JR, Bruce RA, Murray JA. Disparities between aortic and peripheral pulse pressures induced by upright exercise and vasomotor changes in man. Circulation 1968; 37:954-964.
    • (1968) Circulation , vol.37 , pp. 954-964
    • Rowel, L.B.1    Brengelmann, G.L.2    Blackmon, J.R.3    Bruce, R.A.4    Murray, J.A.5
  • 10
    • 0019523842 scopus 로고
    • Direct blood pressure measurement - Dynamic response requirements
    • Gardner RM. Direct blood pressure measurement - Dynamic response requirements. Anesthesiology 1981; 54:227-236.
    • (1981) Anesthesiology , vol.54 , pp. 227-236
    • Gardner, R.M.1
  • 11
    • 0030970060 scopus 로고    scopus 로고
    • Estimation of central aortic pressure waveform by mathematical transformation of radial tonometry pressure; validation of generalized transfer function
    • Chen CH, Nevo E, Fetics B, Pak PH, Yin FCP, Maugham WL, Kass DA. Estimation of central aortic pressure waveform by mathematical transformation of radial tonometry pressure; validation of generalized transfer function. Circulation 1997; 95:1827-1836.
    • (1997) Circulation , vol.95 , pp. 1827-1836
    • Chen, C.H.1    Nevo, E.2    Fetics, B.3    Pak, P.H.4    Yin, F.C.P.5    Maugham, W.L.6    Kass, D.A.7
  • 12
    • 0033546609 scopus 로고    scopus 로고
    • Predicting cardiovascular risk using conventional vs ambulatory blood pressure in older patients with systolic hypertension
    • Staessen JA, Thijs L, Fagard R, O'Brien ET, Clement D, de Leeuw PW, Mancia G, for the Systolic Hypertension in Europe Trial Investigators. Predicting cardiovascular risk using conventional vs ambulatory blood pressure in older patients with systolic hypertension. JAMA 1999; 282:539-546.
    • (1999) JAMA , vol.282 , pp. 539-546
    • Staessen, J.A.1    Thijs, L.2    Fagard, R.3    O'Brien, E.T.4    Clement, D.5    De Leeuw, P.W.6    Mancia, G.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.