메뉴 건너뛰기




Volumn 94, Issue 8, 1996, Pages 1870-1875

Reconstruction of brachial artery pressure from noninvasive finger pressure measurements

Author keywords

arteries; blood pressure; pressure; waves

Indexed keywords

ADULT; AGED; ARTERIAL PRESSURE; ARTICLE; BLOOD PRESSURE MONITORING; BRACHIAL ARTERY; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; FINGER BLOOD FLOW; HUMAN; MAJOR CLINICAL STUDY; MALE; PREDICTION; PRIORITY JOURNAL;

EID: 0029818936     PISSN: 00097322     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.CIR.94.8.1870     Document Type: Article
Times cited : (162)

References (23)
  • 2
    • 0024344783 scopus 로고
    • Comparison of finger and intraarterial blood pressure monitoring in rest and during laboratory tests
    • Parati G, Casadei R, Gropelli A, Di Rienzo M, Mancia G. Comparison of finger and intraarterial blood pressure monitoring in rest and during laboratory tests. Hypertension. 1989;13:647-655.
    • (1989) Hypertension , vol.13 , pp. 647-655
    • Parati, G.1    Casadei, R.2    Gropelli, A.3    Di Rienzo, M.4    Mancia, G.5
  • 3
    • 0026756113 scopus 로고
    • Effects of graded vasoconstriction upon the measurement of finger arterial pressure
    • Imholz BPM, Parati G, Mancia G, Wesseling KH. Effects of graded vasoconstriction upon the measurement of finger arterial pressure. J Hypertens. 1992;10:979-984.
    • (1992) J Hypertens , vol.10 , pp. 979-984
    • Imholz, B.P.M.1    Parati, G.2    Mancia, G.3    Wesseling, K.H.4
  • 4
    • 0026637505 scopus 로고
    • The reliability of noninvasive continuous finger blood pressure measurement in patients with both hypertension and vascular disease
    • Bos WJW, Imholz BPM, van Goudoever J, Wesseling KH, van Montfrans GA. The reliability of noninvasive continuous finger blood pressure measurement in patients with both hypertension and vascular disease. Am J Hypertens. 1992;5:529-535.
    • (1992) Am J Hypertens , vol.5 , pp. 529-535
    • Bos, W.J.W.1    Imholz, B.P.M.2    Van Goudoever, J.3    Wesseling, K.H.4    Van Montfrans, G.A.5
  • 9
    • 85047676115 scopus 로고
    • Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure
    • Imholz BPM, Settels JJ, van den Meiracker AH, Wesseling KH, Wieling W. Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure. Cardiovasc Res. 1990;24:214-221.
    • (1990) Cardiovasc Res , vol.24 , pp. 214-221
    • Imholz, B.P.M.1    Settels, J.J.2    Van den Meiracker, A.H.3    Wesseling, K.H.4    Wieling, W.5
  • 12
    • 0025562437 scopus 로고
    • Reconstruction of brachial arterial pulsation from finger arterial pressure
    • Gizdulich P, Wesseling KH. Reconstruction of brachial arterial pulsation from finger arterial pressure. Proc 12th Int Conf IEEE Eng Med Biol Soc. 1990;12:1046-1047.
    • (1990) Proc 12th int Conf IEEE Eng Med Biol Soc , vol.12 , pp. 1046-1047
    • Gizdulich, P.1    Wesseling, K.H.2
  • 15
    • 0019523842 scopus 로고
    • Direct blood pressure measurement: Dynamic response requirements
    • Gardner RM. Direct blood pressure measurement: dynamic response requirements. Anesthesiology. 1981;54:227-236.
    • (1981) Anesthesiology , vol.54 , pp. 227-236
    • Gardner, R.M.1
  • 18
    • 0027460281 scopus 로고
    • An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man
    • Karamanoglu M, O'Rourke MF, Avolio AP, Kelly RP. An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man. Eur Heart J. 1993;14:160-167.
    • (1993) Eur Heart J , vol.14 , pp. 160-167
    • Karamanoglu, M.1    O'Rourke, M.F.2    Avolio, A.P.3    Kelly, R.P.4
  • 19
    • 0027527079 scopus 로고
    • Aortofemoral transfer function: A method to determine the instantaneous aortic valve gradient in aortic valve stenosis
    • Fitchett DH. Aortofemoral transfer function: a method to determine the instantaneous aortic valve gradient in aortic valve stenosis. J Am Coll Cardiol. 1993;22:1909-1914.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1909-1914
    • Fitchett, D.H.1
  • 20
    • 0025727546 scopus 로고
    • Comparative accuracies of a finger blood pressure monitor and an oscillometric blood pressure monitor
    • Epstein RH, Huffnagle S, Bartowski RR. Comparative accuracies of a finger blood pressure monitor and an oscillometric blood pressure monitor. J Clin Monit. 1991;7:161-167.
    • (1991) J Clin Monit , vol.7 , pp. 161-167
    • Epstein, R.H.1    Huffnagle, S.2    Bartowski, R.R.3
  • 21
    • 10244276864 scopus 로고
    • Segmental measurement of systolic blood pressure in the extremities including the thumb and the great toe
    • Gundersen J. Segmental measurement of systolic blood pressure in the extremities including the thumb and the great toe. Scand J Clin Lab Invest. 1972;29:371-379.
    • (1972) Scand J Clin Lab Invest , vol.29 , pp. 371-379
    • Gundersen, J.1
  • 23
    • 0018174760 scopus 로고
    • Pressure-flow characteristics of coronary stenoses in unsedated dogs at rest and during coronary vasodilation
    • Gould KL. Pressure-flow characteristics of coronary stenoses in unsedated dogs at rest and during coronary vasodilation. Circ Res. 1978;43:242-253.
    • (1978) Circ Res , vol.43 , pp. 242-253
    • Gould, K.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.