메뉴 건너뛰기




Volumn 74, Issue 4, 2002, Pages 1120-1124

A comparison of the in vivo performance of the 19-mm St. Jude Medical Hemodynamic Plus and 21-mm standard valve

Author keywords

[No Author keywords available]

Indexed keywords

ANTICOAGULANT AGENT; LACTATE DEHYDROGENASE;

EID: 0036799936     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0003-4975(02)03891-2     Document Type: Conference Paper
Times cited : (6)

References (18)
  • 1
    • 0028011753 scopus 로고
    • Comparative study of the hydrodynamic function of the size 19mm and 21 mm St. Jude Medical Hemodynamic Plus bileaflet heart valves
    • Fisher J. Comparative study of the hydrodynamic function of the size 19mm and 21 mm St. Jude Medical Hemodynamic Plus bileaflet heart valves. J Heart Valve Dis 1994;3:75-80.
    • (1994) J Heart Valve Dis , vol.3 , pp. 75-80
    • Fisher, J.1
  • 2
    • 0015043899 scopus 로고
    • Left ventricular volumes and ejection fraction by echocardiography
    • Pombo JF, Troy BL, Russel RO Jr. Left ventricular volumes and ejection fraction by echocardiography. Circulation 1971;43:480-90.
    • (1971) Circulation , vol.43 , pp. 480-490
    • Pombo, J.F.1    Troy, B.L.2    Russel R.O., Jr.3
  • 3
    • 0017331788 scopus 로고
    • Echocardiographic determination of left ventricle mass in man. Anatomic validation of the method
    • Devereux RN, Reichek N. Echocardiographic determination of left ventricle mass in man. Anatomic validation of the method. Circulation 1977;55:613-9.
    • (1977) Circulation , vol.55 , pp. 613-619
    • Devereux, R.N.1    Reichek, N.2
  • 5
    • 0018905390 scopus 로고
    • Evaluation of aortic valve replacement in patients with valvular aortic stenosis
    • Henry WL, Bonow RO, Borer JS. Evaluation of aortic valve replacement in patients with valvular aortic stenosis. Circulation 1980;61:814-25.
    • (1980) Circulation , vol.61 , pp. 814-825
    • Henry, W.L.1    Bonow, R.O.2    Borer, J.S.3
  • 6
    • 0028358858 scopus 로고
    • Doppler echocardiography evaluation of the CarboMedics valve in patients with small aortic annulus and valve prosthesis-body surface area mismatch
    • DePaulis R, Sommariva L, Russo F, et al. Doppler echocardiography evaluation of the CarboMedics valve in patients with small aortic annulus and valve prosthesis-body surface area mismatch. J Thorac Cardiovasc Surg 1994;108:57-62.
    • (1994) J Thorac Cardiovasc Surg , vol.108 , pp. 57-62
    • DePaulis, R.1    Sommariva, L.2    Russo, F.3
  • 8
    • 0033819953 scopus 로고    scopus 로고
    • Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention
    • Pibarot P, Dumesnil JG. Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. J Am Coll Cardiol 2000;36:1131-41.
    • (2000) J Am Coll Cardiol , vol.36 , pp. 1131-1141
    • Pibarot, P.1    Dumesnil, J.G.2
  • 9
    • 0029969583 scopus 로고    scopus 로고
    • Early in vivo experience with the hemodynamic plus St. Jude Medical heart valves in patients with narrowed aortic annulus
    • Carrel T, Zingg U, Jenni R, Aeschbacher B, Turina MI. Early in vivo experience with the hemodynamic plus St. Jude Medical heart valves in patients with narrowed aortic annulus. Ann Thorac Surg 1996;61:1418-22.
    • (1996) Ann Thorac Surg , vol.61 , pp. 1418-1422
    • Carrel, T.1    Zingg, U.2    Jenni, R.3    Aeschbacher, B.4    Turina, M.I.5
  • 10
    • 0030741138 scopus 로고    scopus 로고
    • Hemodynamic performance of the St. Jude Medical Hemodynamic Plus Valve
    • Hayashida N, Isomura T, Hisatomi K, et al. Hemodynamic performance of the St. Jude Medical Hemodynamic Plus Valve. Artificial Organs 1997;21:916-21.
    • (1997) Artificial Organs , vol.21 , pp. 916-921
    • Hayashida, N.1    Isomura, T.2    Hisatomi, K.3
  • 14
    • 0025179228 scopus 로고
    • Validation and application of indexed aortic prosthetic valve areas calculated by Doppler echocardiography
    • Dumesnil JG, Honos GN, Lemieux M, Beauchemin J. Validation and application of indexed aortic prosthetic valve areas calculated by Doppler echocardiography. J Am Coll Cardiol 1990;16:637-43.
    • (1990) J Am Coll Cardiol , vol.16 , pp. 637-643
    • Dumesnil, J.G.1    Honos, G.N.2    Lemieux, M.3    Beauchemin, J.4
  • 16
    • 0028249325 scopus 로고
    • Influence of prosthesis size on change in left ventricular mass following aortic valve replacement
    • Sim EKW, Orszulak TA, Schaff HV, Shub C. Influence of prosthesis size on change in left ventricular mass following aortic valve replacement. Eur J Cardiothorac Surg 1994;8:293-7.
    • (1994) Eur J Cardiothorac Surg , vol.8 , pp. 293-297
    • Sim, E.K.W.1    Orszulak, T.A.2    Schaff, H.V.3    Shub, C.4
  • 17
    • 0031148992 scopus 로고    scopus 로고
    • Impact of size mismatch and left ventricular function on performance of the St. Jude disc valve after aortic valve replacement
    • Lund O, Emmertsen K, Nielsen T, et al. Impact of size mismatch and left ventricular function on performance of the St. Jude disc valve after aortic valve replacement. Ann Thorac Surg 1997;63:1227-34.
    • (1997) Ann Thorac Surg , vol.63 , pp. 1227-1234
    • Lund, O.1    Emmertsen, K.2    Nielsen, T.3
  • 18
    • 0024261148 scopus 로고
    • In vitro comparison of aortic heart valve prostheses. Part I: Mechanical valves
    • Knott E, Reul H, Knoch M, Steinseifer U, Rau G. In vitro comparison of aortic heart valve prostheses. Part I: mechanical valves. J Thorac Cardiovasc Surg 1988;96:952-6.
    • (1988) J Thorac Cardiovasc Surg , vol.96 , pp. 952-956
    • Knott, E.1    Reul, H.2    Knoch, M.3    Steinseifer, U.4    Rau, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.