메뉴 건너뛰기




Volumn 21, Issue 8, 1997, Pages 916-921

Hemodynamic performance of the St. Jude Medical Hemodynamic Plus valve

Author keywords

aortic valve replacement; Doppler echocardiography; hemodynamic performance; St. Jude Medical Hemodynamic Plus valve; St. Jude Medical valve

Indexed keywords

BLOOD VESSELS; FLOW VELOCITY; HEMODYNAMICS;

EID: 0030741138     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1525-1594.1997.tb00251.x     Document Type: Article
Times cited : (8)

References (24)
  • 1
    • 0018104133 scopus 로고
    • The problem of valve prosthesis-patient mismatch
    • Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation 1978;58:20-4.
    • (1978) Circulation , vol.58 , pp. 20-24
    • Rahimtoola, S.H.1
  • 4
    • 0028011753 scopus 로고
    • Comparative study of the hydrodynamic function of the size 19mm and 21mm St. Jude Medical Hemodynamic Plus bileaflet heart valve
    • Fisher J. Comparative study of the hydrodynamic function of the size 19mm and 21mm St. Jude Medical Hemodynamic Plus bileaflet heart valve. J Heart Valve Dis 1994;3:75-80.
    • (1994) J Heart Valve Dis , vol.3 , pp. 75-80
    • Fisher, J.1
  • 5
    • 0029969583 scopus 로고    scopus 로고
    • Early in vivo experience with the Hemodynamic Plus St. Jude Medical heart valves in patients with narrowed aortic annulus
    • Carrel T, Zingg U, Jenni R, Aeschbacher B, Turina MI. Early in vivo experience with the Hemodynamic Plus St. Jude Medical heart valves in patients with narrowed aortic annulus. Ann Thorac Surg 1996;61:1418-22.
    • (1996) Ann Thorac Surg , vol.61 , pp. 1418-1422
    • Carrel, T.1    Zingg, U.2    Jenni, R.3    Aeschbacher, B.4    Turina, M.I.5
  • 6
    • 0021816125 scopus 로고
    • Continuous-Wave Doppler echocardiographic assessment of severity of calcific aortic stenosis: A simultaneous Doppler-catheter correlative study in 100 adult patients
    • Currie PJ, Seward JB, Reeder GS, Vlietstra RE, Bresnahan DR, Bresnahan JF, Smith HC, Hagler DJ. Tajik AJ. Continuous-Wave Doppler echocardiographic assessment of severity of calcific aortic stenosis: A simultaneous Doppler-catheter correlative study in 100 adult patients. Circulation 1985;71: 1162-9.
    • (1985) Circulation , vol.71 , pp. 1162-1169
    • Currie, P.J.1    Seward, J.B.2    Reeder, G.S.3    Vlietstra, R.E.4    Bresnahan, D.R.5    Bresnahan, J.F.6    Smith, H.C.7    Hagler, D.J.8    Tajik, A.J.9
  • 8
    • 0027212706 scopus 로고
    • Clinical evaluation with exercise performance in twenty patients who underwent coronary artery bypass grafting with both the gastroepiploic and internal thoracic arteries
    • Isomura T, Hisatomi K, Hirano A, Hayashida N, Matsuzoe S, Ohishi K. Clinical evaluation with exercise performance in twenty patients who underwent coronary artery bypass grafting with both the gastroepiploic and internal thoracic arteries. J Thorac Cardiovasc Surg 1993;105:1088-94.
    • (1993) J Thorac Cardiovasc Surg , vol.105 , pp. 1088-1094
    • Isomura, T.1    Hisatomi, K.2    Hirano, A.3    Hayashida, N.4    Matsuzoe, S.5    Ohishi, K.6
  • 9
    • 0023787776 scopus 로고
    • Guidelines for reporting morbidity and mortality after cardiac valvular operations
    • Edmunds LH, Clark RE, Cohn LH, Miller DC, Weisel RD. Guidelines for reporting morbidity and mortality after cardiac valvular operations. Ann Thorac Surg 1988;46:257-9.
    • (1988) Ann Thorac Surg , vol.46 , pp. 257-259
    • Edmunds, L.H.1    Clark, R.E.2    Cohn, L.H.3    Miller, D.C.4    Weisel, R.D.5
  • 10
    • 84985218172 scopus 로고
    • Heart valve replacement with St. Jude Medical prosthesis: Long-term clinical results and hemolysis after implantation
    • Isomura T, Nishi K, Tanaka K, Hisatomi K, Hirano A, Kawara T, Ohishi K. Heart valve replacement with St. Jude Medical prosthesis: Long-term clinical results and hemolysis after implantation. Artif Organs 1991;14(Suppl 4):99-102.
    • (1991) Artif Organs , vol.14 , Issue.4 SUPPL. , pp. 99-102
    • Isomura, T.1    Nishi, K.2    Tanaka, K.3    Hisatomi, K.4    Hirano, A.5    Kawara, T.6    Ohishi, K.7
  • 14
    • 0019460867 scopus 로고
    • Hemodynamic evaluation of the St. Jude Medical valve prosthesis in the small aortic anulus
    • Wortham DC, Tri TB, Bowen TE. Hemodynamic evaluation of the St. Jude Medical valve prosthesis in the small aortic anulus. J Thorac Cardiovasc Surg 1981;81:615-20.
    • (1981) J Thorac Cardiovasc Surg , vol.81 , pp. 615-620
    • Wortham, D.C.1    Tri, T.B.2    Bowen, T.E.3
  • 15
    • 0028065258 scopus 로고
    • Long term clinical outcome with small size standard St. Jude Medical valves implanted in the aortic position
    • Arom KV, Goldenberg IF, Emery RW. Long term clinical outcome with small size standard St. Jude Medical valves implanted in the aortic position. J Heart Valve Dis 1994;3:531-6.
    • (1994) J Heart Valve Dis , vol.3 , pp. 531-536
    • Arom, K.V.1    Goldenberg, I.F.2    Emery, R.W.3
  • 19
    • 0017688504 scopus 로고
    • Left ventricular function before and following aortic valve replacement
    • Kennedy JW, Doces J, Stewart DK. Left ventricular function before and following aortic valve replacement. Circulation 1977;56:409-13.
    • (1977) Circulation , vol.56 , pp. 409-413
    • Kennedy, J.W.1    Doces, J.2    Stewart, D.K.3
  • 21
    • 8544255814 scopus 로고
    • Left ventricular function during exercise in patients with aortic valve disease
    • Jehle J, Lauber A, Spiller P, Uhlmann D. Left ventricular function during exercise in patients with aortic valve disease. Circulation 1983;68:99-103.
    • (1983) Circulation , vol.68 , pp. 99-103
    • Jehle, J.1    Lauber, A.2    Spiller, P.3    Uhlmann, D.4
  • 22
    • 0025259530 scopus 로고
    • Serial assessment of ventricular performance after valve replacement for aortic stenosis
    • Harpole DH, Jones RH. Serial assessment of ventricular performance after valve replacement for aortic stenosis. J Thorac Cardiovasc Surg 1990;99:645-50.
    • (1990) J Thorac Cardiovasc Surg , vol.99 , pp. 645-650
    • Harpole, D.H.1    Jones, R.H.2
  • 23
    • 0016335111 scopus 로고
    • Indices predicting long-term survival after valve replacement in patients with aortic regurgitation and patients with aortic stenosis
    • Hirshfeld JW, Epstein SE, Roberts AJ, Glancy DL, Morrow AG. Indices predicting long-term survival after valve replacement in patients with aortic regurgitation and patients with aortic stenosis. Circulation 1974;50:1190-9.
    • (1974) Circulation , vol.50 , pp. 1190-1199
    • Hirshfeld, J.W.1    Epstein, S.E.2    Roberts, A.J.3    Glancy, D.L.4    Morrow, A.G.5
  • 24
    • 0017177460 scopus 로고
    • The influence of ventricular function on the results of aortic valve replacement for aortic stenosis
    • Taw RJ, Pipkin R, Fortuin NJ, Brawley RK. The influence of ventricular function on the results of aortic valve replacement for aortic stenosis. Johns Hopkins Med J 1976;139:85.
    • (1976) Johns Hopkins Med J , vol.139 , pp. 85
    • Taw, R.J.1    Pipkin, R.2    Fortuin, N.J.3    Brawley, R.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.