메뉴 건너뛰기




Volumn 10, Issue 5, 2002, Pages 350-354

Implantable hearing devices: Contemporary options

(2)  Wood, Mark W a   Hough, J V D a  

a NONE   (United States)

Author keywords

[No Author keywords available]

Indexed keywords

AUDITORY REHABILITATION; COST EFFECTIVENESS ANALYSIS; DEVICE; ESTHETIC SURGERY; FEEDBACK SYSTEM; FOOD AND DRUG ADMINISTRATION; HEARING AID; HEARING IMPAIRMENT; HUMAN; IMPLANT; MEDICAL LITERATURE; PERCEPTION DEAFNESS; PRIORITY JOURNAL; REVIEW; RISK BENEFIT ANALYSIS; THEORY; UNITED STATES;

EID: 0036797811     PISSN: 10689508     EISSN: None     Source Type: Journal    
DOI: 10.1097/00020840-200210000-00003     Document Type: Review
Times cited : (3)

References (18)
  • 1
    • 0034990175 scopus 로고    scopus 로고
    • Biomaterials for implantable middle ear hearing devices
    • Dormer KJ, Gan RZ: Biomaterials for implantable middle ear hearing devices. Otolaryngol Clin North Am 2001, 34:289-297.
    • (2001) Otolaryngol Clin North Am , vol.34 , pp. 289-297
    • Dormer, K.J.1    Gan, R.Z.2
  • 2
    • 0034985427 scopus 로고    scopus 로고
    • Implantable middle ear hearing devices: Food and Drug Administration review process
    • Jaffee IS: Implantable middle ear hearing devices: Food and Drug Administration review process. Otolaryngol Clin North Am 2001, 34:515-517.
    • (2001) Otolaryngol Clin North Am , vol.34 , pp. 515-517
    • Jaffee, I.S.1
  • 3
    • 0141693330 scopus 로고    scopus 로고
    • Current status and critical reflections on implantable hearing aids
    • Hüttenbrink KB: Current status and critical reflections on implantable hearing aids. Am J Otol 1999, 20:409-415.
    • (1999) Am J Otol , vol.20 , pp. 409-415
    • Hüttenbrink, K.B.1
  • 5
    • 0034988194 scopus 로고    scopus 로고
    • Long-term results using a piezoelectric semi-implantable middle ear hearing device: The Rion Device E-type
    • Yanagihara N, Sato H, Hinohira Y, et al.: Long-term results using a piezoelectric semi-implantable middle ear hearing device: the Rion Device E-type. Otolaryngol Clin North Am 2001, 34:389-400.
    • (2001) Otolaryngol Clin North Am , vol.34 , pp. 389-400
    • Yanagihara, N.1    Sato, H.2    Hinohira, Y.3
  • 6
    • 19044374316 scopus 로고    scopus 로고
    • Phase III clinical trial results with the Vibrant Soundbridge implantable middle ear hearing device: A prospective controlled multicenter study
    • Luetje CM, Brackman D, Balkany TJ, et al.: Phase III clinical trial results with the Vibrant Soundbridge implantable middle ear hearing device: a prospective controlled multicenter study. Otolaryngol Head Neck Surg 2002, 126:97-107.
    • (2002) Otolaryngol Head Neck Surg , vol.126 , pp. 97-107
    • Luetje, C.M.1    Brackman, D.2    Balkany, T.J.3
  • 7
    • 0034981089 scopus 로고    scopus 로고
    • Semi-implantable electromagnetic middle ear hearing device for moderate to severe sensorineural hearing loss
    • Hough JV, Dyer RK Jr, Matthews P, et al.: Semi-implantable electromagnetic middle ear hearing device for moderate to severe sensorineural hearing loss. Otolaryngol Clin North Am 2001, 34:401-416.
    • (2001) Otolaryngol Clin North Am , vol.34 , pp. 401-416
    • Hough, J.V.1    Dyer R.K., Jr.2    Matthews, P.3
  • 8
    • 0034993012 scopus 로고    scopus 로고
    • Total implantation of the Implex TICA hearing amplifier implant for high-frequency sensorineural hearing loss
    • Zenner HP, Leysieffer H: Total implantation of the Implex TICA hearing amplifier implant for high-frequency sensorineural hearing loss. Otolaryngol Clin North Am 2001, 34:417-446.
    • (2001) Otolaryngol Clin North Am , vol.34 , pp. 417-446
    • Zenner, H.P.1    Leysieffer, H.2
  • 9
    • 0034798981 scopus 로고    scopus 로고
    • Verification of improved patient outcomes with a partially implantable hearing aid, the SOUNDTEC direct hearing system
    • Roland PS, Shoup AG, Shea MC, et al.: Verification of improved patient outcomes with a partially implantable hearing aid, the SOUNDTEC direct hearing system. Laryngoscope 2001, 111:1682-1686.
    • (2001) Laryngoscope , vol.111 , pp. 1682-1686
    • Roland, P.S.1    Shoup, A.G.2    Shea, M.C.3
  • 10
    • 0035165660 scopus 로고    scopus 로고
    • Early clinical results: SOUNDTEC implantable hearing device phase II study
    • Hough JV, Dyer RK Jr, Matthews P, et al.: Early clinical results: SOUNDTEC implantable hearing device phase II study. Laryngoscope 2001, 111:1-8.
    • (2001) Laryngoscope , vol.111 , pp. 1-8
    • Hough, J.V.1    Dyer R.K., Jr.2    Matthews, P.3
  • 11
    • 0035190816 scopus 로고    scopus 로고
    • A multicenter study of the Vibrant Soundbridge middle ear implant: Early clinical results and experience
    • Fraysse B, Lavieille JP, Schmerber S, et al.: A multicenter study of the Vibrant Soundbridge middle ear implant: early clinical results and experience. Otol Neurotol 2001, 22:952-961.
    • (2001) Otol Neurotol , vol.22 , pp. 952-961
    • Fraysse, B.1    Lavieille, J.P.2    Schmerber, S.3
  • 12
    • 0034769325 scopus 로고    scopus 로고
    • Total implantation of the active hearing implant TICA for middle ear disease: A temporal bone study
    • Maassen MM, Lehner R, Leysieffer H, et al.: Total implantation of the active hearing implant TICA for middle ear disease: a temporal bone study. Ann Otol Rhinol Laryngol 2001, 110:912-916.
    • (2001) Ann Otol Rhinol Laryngol , vol.110 , pp. 912-916
    • Maassen, M.M.1    Lehner, R.2    Leysieffer, H.3
  • 13
    • 0034981721 scopus 로고    scopus 로고
    • Bioelectronic microphone options for a totally implantable hearing device for partial and total hearing loss
    • Maniglia AJ, Murray G, Arnold JE, et al.: Bioelectronic microphone options for a totally implantable hearing device for partial and total hearing loss. Otolaryngol Clin North Am 2001, 34:469-483.
    • (2001) Otolaryngol Clin North Am , vol.34 , pp. 469-483
    • Maniglia, A.J.1    Murray, G.2    Arnold, J.E.3
  • 14
    • 0035216855 scopus 로고    scopus 로고
    • Vibrant semi-implantable hearing device with digital sound processing: Effective gain and speech perception
    • Snik AF, Cremers CW: Vibrant semi-implantable hearing device with digital sound processing: effective gain and speech perception. Arch Otolaryngol Head Neck Surg 2001, 127:1433-1437.
    • (2001) Arch Otolaryngol Head Neck Surg , vol.127 , pp. 1433-1437
    • Snik, A.F.1    Cremers, C.W.2
  • 15
    • 0034982055 scopus 로고    scopus 로고
    • Engineering principles applied to implantable otologic devices
    • Ko WH, Zhu WL, Kane M, et al.: Engineering principles applied to implantable otologic devices. Otolaryngol Clin North Am 2001, 34:299-314.
    • (2001) Otolaryngol Clin North Am , vol.34 , pp. 299-314
    • Ko, W.H.1    Zhu, W.L.2    Kane, M.3
  • 16
    • 0034987194 scopus 로고    scopus 로고
    • Multicenter audiometric results with the Vibrant Soundbridge, a semi-implantable hearing device for sensorineural hearing impairment
    • Snik AFM, Mylanus EA, Cremers CW, et al.: Multicenter audiometric results with the Vibrant Soundbridge, a semi-implantable hearing device for sensorineural hearing impairment. Otolaryngol Clin North Am 2001, 34:373-388.
    • (2001) Otolaryngol Clin North Am , vol.34 , pp. 373-388
    • Snik, A.F.M.1    Mylanus, E.A.2    Cremers, C.W.3
  • 17
    • 0035062061 scopus 로고    scopus 로고
    • Biomechanical aspects in implantable microphones and hearing aids and development of a concept with a hydroacoustical transmission
    • Hüttenbrink KB, Zahnert TH, Bornitz M, et al.: Biomechanical aspects in implantable microphones and hearing aids and development of a concept with a hydroacoustical transmission. Acta Otolaryngol 2001, 121:185-189.
    • (2001) Acta Otolaryngol , vol.121 , pp. 185-189
    • Hüttenbrink, K.B.1    Zahnert, T.H.2    Bornitz, M.3
  • 18
    • 0035181035 scopus 로고    scopus 로고
    • Clinical experience with the Vibrant Soundbridge implant device
    • Fisch U, Cremers CW, Lenarz T, et al.: Clinical experience with the Vibrant Soundbridge implant device. Otol Neurotol 2001, 22:962-972.
    • (2001) Otol Neurotol , vol.22 , pp. 962-972
    • Fisch, U.1    Cremers, C.W.2    Lenarz, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.