메뉴 건너뛰기




Volumn 14, Issue 6, 1999, Pages 865-868

Complications associated with excess cement around crowns on osseointegrated implants: A clinical report

Author keywords

Cement retained implant crowns; Complications; Excess cement

Indexed keywords

TOOTH CEMENT;

EID: 0033218194     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (197)

References (12)
  • 1
    • 0030148130 scopus 로고    scopus 로고
    • Clinical effectiveness of implantsupported single-tooth replacement: The Toronto study
    • Avivi-Arber L, Zarb GA. Clinical effectiveness of implantsupported single-tooth replacement: The Toronto study. Int J Oral Maxillofac Implants 1996;11: 311321.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 311-321
    • Avivi-Arber, L.1    Zarb, G.A.2
  • 2
    • 0025657547 scopus 로고
    • A 3-year follow-up study of early single implant restorations ad modum Brånemark
    • Jemt T, Lekholm Y, Gröndahl K. A 3-year follow-up study of early single implant restorations ad modum Brånemark. Int J Periodontics Restorative Dent 1990;10: 341349.
    • (1990) Int J Periodontics Restorative Dent , vol.10 , pp. 341-349
    • Jemt, T.1    Lekholm, Y.2    Gröndahl, K.3
  • 3
    • 0028393761 scopus 로고
    • Clinical evaluation of single-tooth restorations supported by osseointegrated implants: A retrospective study
    • Ekfeldt A, Carlsson GHE, Borjesson G. Clinical evaluation of single-tooth restorations supported by osseointegrated implants: A retrospective study. Int J Oral Maxillofac Implants 1994;9: 179183.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 179-183
    • Ekfeldt, A.1    Carlsson, G.H.E.2    Borjesson, G.3
  • 4
    • 0026921977 scopus 로고
    • Loads and designs of screw joints for single crowns supported by osseointegrated fixtures
    • Jorneus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated fixtures. Int J Oral Maxillofac Implants 1992;7: 353359.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 353-359
    • Jorneus, L.1    Jemt, T.2    Carlsson, L.3
  • 5
    • 0040991018 scopus 로고
    • The effects of rough surfaces upon gingival tissues
    • Waerhaug J. The effects of rough surfaces upon gingival tissues. J Dent Res 1956;35: 323
    • (1956) J Dent Res , vol.35 , pp. 323
    • Waerhaug, J.1
  • 6
    • 0020850773 scopus 로고
    • Clinical and microbiological effects of subgingival restorations with overhanging or clinically perfect margins
    • Lang NP, Kiel RA, Anderhalden K. Clinical and microbiological effects of subgingival restorations with overhanging or clinically perfect margins. J Clin Periodontol 1983;10: 563578.
    • (1983) J Clin Periodontol , vol.10 , pp. 563-578
    • Lang, N.P.1    Kiel, R.A.2    Anderhalden, K.3
  • 7
    • 0031108001 scopus 로고    scopus 로고
    • Effects of subgingival chlorexidine irrigation on periimplant maintenance
    • Felo A, Shibly O, Ciancio SG, Laurello FR. Effects of subgingival chlorexidine irrigation on periimplant maintenance. J Am Dent Assoc 1997;10: 107110.
    • (1997) J Am Dent Assoc , vol.10 , pp. 107-110
    • Felo, A.1    Shibly, O.2    Ciancio, S.G.3    Laurello, F.R.4
  • 8
    • 0028390316 scopus 로고
    • Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years
    • Kallus T, Bessing C. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 1994;9: 169178.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 169-178
    • Kallus, T.1    Bessing, C.2
  • 9
    • 0013890346 scopus 로고
    • Marginal fit of gold inlay castings
    • Christensen GJ. Marginal fit of gold inlay castings. J Prosthet Dent 1966;16: 297305.
    • (1966) J Prosthet Dent , vol.16 , pp. 297-305
    • Christensen, G.J.1
  • 10
    • 0031179216 scopus 로고    scopus 로고
    • Cement removal from restorations luted to titanium abutments with simulated subgingival margins
    • Agar JR, Cameron SM, Hughbanks JC, Parker MH. Cement removal from restorations luted to titanium abutments with simulated subgingival margins. J Prosthet Dent 1997;781):: 4347.
    • (1997) J Prosthet Dent , vol.78 , Issue.1 , pp. 43-47
    • Agar, J.R.1    Cameron, S.M.2    Hughbanks, J.C.3    Parker, M.H.4
  • 11
    • 0025472973 scopus 로고
    • The effects of scaling titanium implant surfaces with metal and plastic instruments on cell attachment
    • Dmytryk JJ, Fox SC, Moriarty JD. The effects of scaling titanium implant surfaces with metal and plastic instruments on cell attachment. J Periodontol 1990;61: 491496.
    • (1990) J Periodontol , vol.61 , pp. 491-496
    • Dmytryk, J.J.1    Fox, S.C.2    Moriarty, J.D.3
  • 12
    • 0028399682 scopus 로고
    • Alternative restorative techniques of the CeraOne single-tooth abutment. A technical note
    • Sharifi N, Iok-Chao P, Chai J. Alternative restorative techniques of the CeraOne single-tooth abutment. A technical note. Int J Oral Maxillofac Implants 1994;9: 235238.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 235-238
    • Sharifi, N.1    Iok-Chao, P.2    Chai, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.