메뉴 건너뛰기




Volumn 23, Issue 6, 2002, Pages 510-518

Diagnostic performance of duplex ultrasonography in the detection of high grade internal carotid artery stenosis

Author keywords

Angiography; Carotid duplex ultrasonography; Internal carotid artery stenosis

Indexed keywords

AGED; ANGIOGRAPHY; ARTICLE; CAROTID ARTERY OBSTRUCTION; CLINICAL TRIAL; DOPPLER ECHOGRAPHY; ECHOGRAPHY; FEMALE; HUMAN; MALE; MIDDLE AGED; MULTICENTER STUDY; PREOPERATIVE CARE; PROSPECTIVE STUDY; RADIOGRAPHY; SENSITIVITY AND SPECIFICITY; ADULT; CAROTID ARTERY SURGERY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MULTIPLE REGRESSION; PERIOPERATIVE PERIOD; PRIORITY JOURNAL; SYSTOLE; UNIVERSITY HOSPITAL; VELOCITY;

EID: 0036594156     PISSN: 10785884     EISSN: 15322165     Source Type: Journal    
DOI: 10.1053/ejvs.2002.1621     Document Type: Article
Times cited : (36)

References (24)
  • 2
    • 0025734372 scopus 로고
    • Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade stenosis
    • NORTH AMERICAN SYMPTOMATIC CAROTID ENDARTERECTOMY TRIAL COLLABORATORS. Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade stenosis. N Engl J Med 1991; 325: 445-453.
    • (1991) N Engl J Med , vol.325 , pp. 445-453
  • 3
    • 0025869608 scopus 로고
    • MRC European carotid surgery trial: Interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosis
    • EUROPEAN CAROTID SURGERY TRIALISTS COLLABORATIVE GROUP. MRC European carotid surgery trial: Interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosis. Lancet 1991; 337: 1235-1243.
    • (1991) Lancet , vol.337 , pp. 1235-1243
  • 4
    • 0032499446 scopus 로고    scopus 로고
    • Randomised trial of endarterectomy for recently symptomatic carotid stenosis: Final results of the MRC European Carotid Surgery Trial (ECST)
    • EUROPEAN CAROTID SURGERY TRIALISTS‘ COLLABORATIVE GROUP. Randomised trial of endarterectomy for recently symptomatic carotid stenosis: final results of the MRC European Carotid Surgery Trial (ECST). Lancet 1998; 351: 1379-1387.
    • (1998) Lancet , vol.351 , pp. 1379-1387
  • 5
    • 0025138979 scopus 로고
    • Cerebral angiographic risk in mild cerebrovascular disease
    • HANKEY GJ, WARLOW CP, SELLAR RJ. Cerebral angiographic risk in mild cerebrovascular disease. Stroke 1990; 21: 209-222.
    • (1990) Stroke , vol.21 , pp. 209-222
    • Hankey, G.J.1    Warlow, C.P.2    Sellar, R.J.3
  • 6
    • 0027410697 scopus 로고
    • Correlation of North American Symptomatic Carotid Endarterectomy Trial (NASCET) angiographic definition of 70% to 99% internal carotid artery stenosis with duplex scanning
    • MONETA GL, EDWARDS JM, CHITWOOD RW et al. Correlation of North American Symptomatic Carotid Endarterectomy Trial (NASCET) angiographic definition of 70% to 99% internal carotid artery stenosis with duplex scanning. J Vasc Surg 1993; 17: 152-159.
    • (1993) J Vasc Surg , vol.17 , pp. 152-159
    • Moneta, G.L.1    Edwards, J.M.2    Chitwood, R.W.3
  • 7
    • 0027475543 scopus 로고
    • Detection and quantification of carotid artery stenosis: Efficacy of various Doppler velocity parameters
    • HUNINK MGM, POLAK JF, BARLAN MM, OLEARY DH. Detection and quantification of carotid artery stenosis: Efficacy of various Doppler velocity parameters. AJR 1993; 160: 619-625.
    • (1993) AJR , vol.160 , pp. 619-625
    • Hunink, M.G.M.1    Polak, J.F.2    Barlan, M.M.3    O'Leary, D.H.4
  • 8
    • 0028034044 scopus 로고
    • Reappraisal of duplex criteria to assess significant carotid stenosis with special reference to reports from the North American Symptomatic Carotid Endarterectomy Trial and the European Carotid Surgery Trial
    • NEALE ML, CHAMBERS JL, KELLY AT et al. Reappraisal of duplex criteria to assess significant carotid stenosis with special reference to reports from the North American Symptomatic Carotid Endarterectomy Trial and the European Carotid Surgery Trial. J Vasc Surg 1994; 20: 642-649.
    • (1994) J Vasc Surg , vol.20 , pp. 642-649
    • Neale, M.L.1    Chambers, J.L.2    Kelly, A.T.3
  • 9
    • 0028227034 scopus 로고
    • Color-flow duplex scanning of carotid arteries: New velocity criteria based on receiver operator characteristic analysis for threshold stenoses used in the symptomatic and asymptomatic carotid trials
    • FAUGHT WE, MATTAS MA, VAN BEMMELEN PS et al. Color-flow duplex scanning of carotid arteries: New velocity criteria based on receiver operator characteristic analysis for threshold stenoses used in the symptomatic and asymptomatic carotid trials. J Vasc Surg 1994; 19: 818-828.
    • (1994) J Vasc Surg , vol.19 , pp. 818-828
    • Faught, W.E.1    Mattas, M.A.2    Van Bemmelen, P.S.3
  • 10
    • 0029957459 scopus 로고    scopus 로고
    • Accuracy of duplex sonography before carotid endarterectomy - A comparison with angiography
    • HANSEN F, BERGQVIST D, LINDBLAD B et al. Accuracy of duplex sonography before carotid endarterectomy - A comparison with angiography. Eur J Vasc Endovasc Surg 1996; 12: 331-336.
    • (1996) Eur J Vasc Endovasc Surg , vol.12 , pp. 331-336
    • Hansen, F.1    Bergqvist, D.2    Lindblad, B.3
  • 11
    • 0029915576 scopus 로고    scopus 로고
    • Determination of duplex Doppler ultrasound criteria appropriate to the North American Symptomatic Carotid Endarterectomy Trial
    • CARPENTER JP, LEXA FJ, DAVIS JT. Determination of duplex Doppler ultrasound criteria appropriate to the North American Symptomatic Carotid Endarterectomy Trial. Stroke 1996; 27: 695-699.
    • (1996) Stroke , vol.27 , pp. 695-699
    • Carpenter, J.P.1    Lexa, F.J.2    Davis, J.T.3
  • 12
    • 0030047247 scopus 로고    scopus 로고
    • Prospective evaluation of new duplex criteria to identify 70% internal carotid artery stenosis
    • HOOD DB, MATTOS MA, MANSOUR A et al. Prospective evaluation of new duplex criteria to identify 70% internal carotid artery stenosis. J Vasc Surg 1996; 23: 254-262.
    • (1996) J Vasc Surg , vol.23 , pp. 254-262
    • Hood, D.B.1    Mattos, M.A.2    Mansour, A.3
  • 13
    • 0031036613 scopus 로고    scopus 로고
    • Correlation of peak systolic velocity and angiographic measurements of carotid stenosis revisited
    • ALEXANDROV AV, BRODIE DS, MCLEAN A et al. Correlation of peak systolic velocity and angiographic measurements of carotid stenosis revisited. Stroke 1997; 28: 339-342.
    • (1997) Stroke , vol.28 , pp. 339-342
    • Alexandrov, A.V.1    Brodie, D.S.2    McLean, A.3
  • 14
    • 0023476807 scopus 로고
    • Predicting the normal dimensions of the internal and external carotid arteries from the diameter of the common carotid
    • WILLIAMS MA, NICOLAIDES AN. Predicting the normal dimensions of the internal and external carotid arteries from the diameter of the common carotid. Eur J Vasc Surg 1987; 1: 91-96.
    • (1987) Eur J Vasc Surg , vol.1 , pp. 91-96
    • Williams, M.A.1    Nicolaides, A.N.2
  • 15
    • 0028081401 scopus 로고
    • Equivalence of measurements of carotid stenosis. A comparison of three methods on 1001 angiograms
    • ROTHWELL PM, GIBSON RJ, SLATTERY J, SELLAR RJ, WARLOW CP. Equivalence of measurements of carotid stenosis. A comparison of three methods on 1001 angiograms. Stroke 1994; 25: 2435-2439.
    • (1994) Stroke , vol.25 , pp. 2435-2439
    • Rothwell, P.M.1    Gibson, R.J.2    Slattery, J.3    Sellar, R.J.4    Warlow, C.P.5
  • 16
    • 0023226747 scopus 로고
    • ROC steady: A receiver operating characteristic curve that is invariant relative to selection bias
    • DIAMOND GA. ROC steady: a receiver operating characteristic curve that is invariant relative to selection bias. Med Decis Making 1987; 7: 238-243.
    • (1987) Med Decis Making , vol.7 , pp. 238-243
    • Diamond, G.A.1
  • 17
    • 0034038031 scopus 로고    scopus 로고
    • Carotid endarterectomy based on duplex ultrasonography: A safe approach associated with long-term stroke prevention
    • SAMSON RH, BANDYK DF, SHOWALTER DP, YUNIS JP. Carotid endarterectomy based on duplex ultrasonography: a safe approach associated with long-term stroke prevention. Vasc Surg 2000; 34: 125-136.
    • (2000) Vasc Surg , vol.34 , pp. 125-136
    • Samson, R.H.1    Bandyk, D.F.2    Showalter, D.P.3    Yunis, J.P.4
  • 18
    • 0029116354 scopus 로고
    • Accuracy and prognostic consequences of ultrasonography in identifying severe carotid artery stenosis
    • ELIASZIW M, RANKIN RN, FOX AJ, HAYNES RB, BARNETT HJM. Accuracy and prognostic consequences of ultrasonography in identifying severe carotid artery stenosis. Stroke 1995; 26: 1747-1752.
    • (1995) Stroke , vol.26 , pp. 1747-1752
    • Eliasziw, M.1    Rankin, R.N.2    Fox, A.J.3    Haynes, R.B.4    Barnett, H.J.M.5
  • 19
    • 0029847361 scopus 로고    scopus 로고
    • An approach for the use of Doppler ultrasound as a screening tool for hemodynamically significant stenosis (despite heterogeneity of Doppler performance). A multicenter experience
    • HOWARD G, BAKER WH, CHAMBLESS LE et al. An approach for the use of Doppler ultrasound as a screening tool for hemodynamically significant stenosis (despite heterogeneity of Doppler performance). A multicenter experience. Stroke 1996; 27: 1951-1957.
    • (1996) Stroke , vol.27 , pp. 1951-1957
    • Howard, G.1    Baker, W.H.2    Chambless, L.E.3
  • 20
    • 0032446548 scopus 로고    scopus 로고
    • Evaluating institutional variability of duplex scanning in the detection of carotid artery stenosis
    • CRISWELL BK, LANGSFELD M, TULLIS MJ, MAREK J. Evaluating institutional variability of duplex scanning in the detection of carotid artery stenosis. Am J Surg 1998; 176: 591-597.
    • (1998) Am J Surg , vol.176 , pp. 591-597
    • Criswell, B.K.1    Langsfeld, M.2    Tullis, M.J.3    Marek, J.4
  • 21
    • 0000682899 scopus 로고
    • Intrinsic spectral broadening: A potential cause of misdiagnosis of carotid artery disease
    • THRUSH AJ, EVANS DH. Intrinsic spectral broadening: a potential cause of misdiagnosis of carotid artery disease. J Vasc Invest 1995; 1: 187-192.
    • (1995) J Vasc Invest , vol.1 , pp. 187-192
    • Thrush, A.J.1    Evans, D.H.2
  • 22
    • 0030065280 scopus 로고    scopus 로고
    • Accuracy of maximum velocity estimates made using Doppler ultrasound systems
    • HOSKINS PR. Accuracy of maximum velocity estimates made using Doppler ultrasound systems. Brit J Radiol 1996; 69: 172-177.
    • (1996) Brit J Radiol , vol.69 , pp. 172-177
    • Hoskins, P.R.1
  • 23
    • 0032452220 scopus 로고    scopus 로고
    • Carotid duplex ultrasonography: Importance of standardisation
    • BYRD S, ROBLESS P, BAXTER A, EMSON M, HALLIDAY A. Carotid duplex ultrasonography: importance of standardisation. Int Angiol 1998; 17: 248-254.
    • (1998) Int Angiol , vol.17 , pp. 248-254
    • Byrd, S.1    Robless, P.2    Baxter, A.3    Emson, M.4    Halliday, A.5
  • 24
    • 0030769524 scopus 로고    scopus 로고
    • Blood flow velocity measurements for carotid stenosis estimation: Interobserver variation and inter-equipment variability
    • RANKE C, TRAPPE HJ. Blood flow velocity measurements for carotid stenosis estimation: interobserver variation and inter-equipment variability. VASA 1997; 26: 210-214.
    • (1997) VASA , vol.26 , pp. 210-214
    • Ranke, C.1    Trappe, H.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.