-
1
-
-
0025734372
-
Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade stenosis
-
1. North American Symptomatic Carotid Endarterectomy Trial Collaborators. Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade stenosis. NEJM. 1991;325:445-453.
-
(1991)
NEJM
, vol.325
, pp. 445-453
-
-
-
2
-
-
0025869608
-
MRC European Carotid Surgery Trial: Interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosis
-
2. European Carotid Surgery Trialists' Collaborative Group. MRC European Carotid Surgery Trial: interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosis. Lancet. 1991;337:1235-1243.
-
(1991)
Lancet
, vol.337
, pp. 1235-1243
-
-
-
3
-
-
0028938324
-
Endarterectomy for asymptomatic carotid artery stenosis
-
3. Executive Committee for the Asymptomatic Carotid Atheroscerosis Study. Endarterectomy for asymptomatic carotid artery stenosis. JAMA. 1995;273:1421-1428.
-
(1995)
JAMA
, vol.273
, pp. 1421-1428
-
-
-
4
-
-
0027514986
-
The role of duplex scanning and arteriography before carotid endarterectomy: A prospective study
-
4. Dawson DL, Zierler RE, Strandness DE Jr, et al. The role of duplex scanning and arteriography before carotid endarterectomy: a prospective study. J Vasc Surg. 1993;18:673-683.
-
(1993)
J Vasc Surg
, vol.18
, pp. 673-683
-
-
Dawson, D.L.1
Zierler, R.E.2
Strandness D.E., Jr.3
-
5
-
-
0029775605
-
Carotid endarterectomy without angiography: Guidelines for duplex Evaluation
-
5. Zaweski JE, Musson AM, Zowolak RM. Carotid endarterectomy without angiography: guidelines for duplex Evaluation. J Vasc Tech. 1996;20(3):151-156.
-
(1996)
J Vasc Tech
, vol.20
, Issue.3
, pp. 151-156
-
-
Zaweski, J.E.1
Musson, A.M.2
Zowolak, R.M.3
-
6
-
-
0025231309
-
Carotid endarterectomy without angiography
-
6. Gelabert HA, Moore WS. Carotid endarterectomy without angiography. Surg Clin North Am. 1990;70:213-223.
-
(1990)
Surg Clin North Am
, vol.70
, pp. 213-223
-
-
Gelabert, H.A.1
Moore, W.S.2
-
7
-
-
0028814571
-
Assessment of carotid artery stenosis by ultrasonography, conventional angiography, and magnetic resonance angiography: Correlation with ex vivo measurement of plaque stenosis
-
7. Pan XM, Saloner D, Reilly LM, et al. Assessment of carotid artery stenosis by ultrasonography, conventional angiography, and magnetic resonance angiography: correlation with ex vivo measurement of plaque stenosis. J Vasc Surg. 1995;21:82-89.
-
(1995)
J Vasc Surg
, vol.21
, pp. 82-89
-
-
Pan, X.M.1
Saloner, D.2
Reilly, L.M.3
-
8
-
-
0027410697
-
Correlation of North American Symptomatic Carotid Endarterectomy Trial (NASCET) angiographic definition of 70% to 99% internal carotid artery stenosis with duplex scanning
-
8. Moneta GL, Edwards JM, Chitwood RW, et al. Correlation of North American Symptomatic Carotid Endarterectomy Trial (NASCET) angiographic definition of 70% to 99% internal carotid artery stenosis with duplex scanning. J Vasc Surg. 1993;17:152-157.
-
(1993)
J Vasc Surg
, vol.17
, pp. 152-157
-
-
Moneta, G.L.1
Edwards, J.M.2
Chitwood, R.W.3
-
9
-
-
0031017932
-
Consistency of doppler parameters in predicting arteriographically confirmed carotid stenosis
-
9. Schwartz SW, Chambless LE, Baker WH, et al. Consistency of doppler parameters in predicting arteriographically confirmed carotid stenosis. Stroke. 1997;28:343-347.
-
(1997)
Stroke
, vol.28
, pp. 343-347
-
-
Schwartz, S.W.1
Chambless, L.E.2
Baker, W.H.3
-
10
-
-
0031036613
-
Correlation of peak systolic velocity and angiographic measurement of carotid stenosis revisited
-
10. Alexandrov AV, Brodie DS, McLean A, et al. Correlation of peak systolic velocity and angiographic measurement of carotid stenosis revisited. Stroke. 1997;28:339-342.
-
(1997)
Stroke
, vol.28
, pp. 339-342
-
-
Alexandrov, A.V.1
Brodie, D.S.2
McLean, A.3
-
11
-
-
0027475543
-
Detection and quantification of carotid artery stenosis: Efficacy of various doppler velocity parameters
-
11. Hunink MGM, Polak JF, Barlan MM, O'Leary DH. Detection and quantification of carotid artery stenosis: efficacy of various doppler velocity parameters. Am J Radiol. 1993;160:619-625.
-
(1993)
Am J Radiol
, vol.160
, pp. 619-625
-
-
Hunink, M.G.M.1
Polak, J.F.2
Barlan, M.M.3
O'Leary, D.H.4
-
12
-
-
0028227034
-
Color-flow duplex scanning of carotid arteries: New velocity criteria based on receiver operator characteristic analysis for threshold stenosis used in the symptomatic and asymptomatic carotid trials
-
12. Faught WE, Mattos MA, van Bemmelen PS, et al. Color-flow duplex scanning of carotid arteries: new velocity criteria based on receiver operator characteristic analysis for threshold stenosis used in the symptomatic and asymptomatic carotid trials. J Vasc Surg. 1994;19:818-827.
-
(1994)
J Vasc Surg
, vol.19
, pp. 818-827
-
-
Faught, W.E.1
Mattos, M.A.2
Van Bemmelen, P.S.3
-
13
-
-
0000995966
-
Ratio of peak systolic velocity of internal carotid to end diastolic velocity of common carotid: New duplex criteria for grading internal carotid stenosis
-
13. Dhanjil S, Jameel M, Nicolaides A, et al. Ratio of peak systolic velocity of internal carotid to end diastolic velocity of common carotid: new duplex criteria for grading internal carotid stenosis. J Vasc Tech. 1997;21:237-240.
-
(1997)
J Vasc Tech
, vol.21
, pp. 237-240
-
-
Dhanjil, S.1
Jameel, M.2
Nicolaides, A.3
-
14
-
-
0030769524
-
Blood flow velocity measurements for carotid stenosis estimation: Interobserver variation and interequipment variability
-
14. Ranke C, Trappe HJ. Blood flow velocity measurements for carotid stenosis estimation: interobserver variation and interequipment variability. Vasa. 1997;26:210-214.
-
(1997)
Vasa
, vol.26
, pp. 210-214
-
-
Ranke, C.1
Trappe, H.J.2
-
15
-
-
0013483165
-
-
Department of Clinical Chemistry, University Hospital, University of Turku, Finland
-
15. Graph ROC. Department of Clinical Chemistry, University Hospital, University of Turku, Finland, 1998.
-
(1998)
-
-
Graph, R.O.C.1
-
16
-
-
0000123717
-
Overestimation of velocities and frequency values by multielement linear array dopplers
-
16. Daigle RJ, Stavros AT, Lee RM. Overestimation of velocities and frequency values by multielement linear array dopplers. J Vasc Tech. 1990;14:206-213.
-
(1990)
J Vasc Tech
, vol.14
, pp. 206-213
-
-
Daigle, R.J.1
Stavros, A.T.2
Lee, R.M.3
-
17
-
-
0013514272
-
Development of a clinical competency plan and career ladder for vascular technologists
-
17. Miles CK, Carter KA. Development of a clinical competency plan and career ladder for vascular technologists. J Vasc Tech. 1997;21:39-41.
-
(1997)
J Vasc Tech
, vol.21
, pp. 39-41
-
-
Miles, C.K.1
Carter, K.A.2
-
18
-
-
0027761058
-
Reproducibility of carotid duplex scanning for a quality assurance program
-
18. Thompson T, Sutton-Tyrrell K, Johnson D, Wolfson SK. Reproducibility of carotid duplex scanning for a quality assurance program. J Vasc Tech. 1993;17:295-298.
-
(1993)
J Vasc Tech
, vol.17
, pp. 295-298
-
-
Thompson, T.1
Sutton-Tyrrell, K.2
Johnson, D.3
Wolfson, S.K.4
-
19
-
-
0001112728
-
Doppler peak systolic velocity measurements: Correction of angle-dependent errors
-
19. Scissons RP, Salles-Cunha S, Altenburg L, et al. Doppler peak systolic velocity measurements: correction of angle-dependent errors. J Vasc Tech. 1997;21:233-236.
-
(1997)
J Vasc Tech
, vol.21
, pp. 233-236
-
-
Scissons, R.P.1
Salles-Cunha, S.2
Altenburg, L.3
-
20
-
-
0030010633
-
Graft surveillance and variance of flow variables: Number of measurements per test
-
20. Salles-Cunha S, Scissons RP, Beebe HG, et al. Graft surveillance and variance of flow variables: number of measurements per test. J Vasc Tech. 1996;20:87-89.
-
(1996)
J Vasc Tech
, vol.20
, pp. 87-89
-
-
Salles-Cunha, S.1
Scissons, R.P.2
Beebe, H.G.3
-
21
-
-
0028021349
-
Graft blood flow rate and systolic velocity: Measurement variability
-
21. Salles-Cunha SX. Graft blood flow rate and systolic velocity: measurement variability. J Vasc Tech. 1994;18:173-176.
-
(1994)
J Vasc Tech
, vol.18
, pp. 173-176
-
-
Salles-Cunha, S.X.1
-
22
-
-
0028296098
-
A method for minimizing variability in kidney length measurement during renal artery duplex stenosis
-
22. Isaacson JA, Zierler RE, Bergelin RO, et al. A method for minimizing variability in kidney length measurement during renal artery duplex stenosis. J Vasc Tech. 1994;18:23-27.
-
(1994)
J Vasc Tech
, vol.18
, pp. 23-27
-
-
Isaacson, J.A.1
Zierler, R.E.2
Bergelin, R.O.3
|