-
1
-
-
0032130902
-
Subcellular optochemical nanobiosensors: Probes encapsulated by biologically localized embedding (PEBBLEs)
-
Clark, H.A., S.L.R. Barker, R. Kopelman, M. Hoyer, and M.A. Philbert, Subcellular optochemical nanobiosensors: probes encapsulated by biologically localized embedding (PEBBLEs). Sensors and Actuators B, 1998. 51: p. 12-16.
-
(1998)
Sensors and Actuators B
, vol.51
, pp. 12-16
-
-
Clark, H.A.1
Barker, S.L.R.2
Kopelman, R.3
Hoyer, M.4
Philbert, M.A.5
-
2
-
-
0033231311
-
Optical nanosensors for chemical analysis inside single living cells. 1. Fabrication, characterization, and methods for intracellular delivery of PEBBLE sensors
-
Clark, H.A., M. Hoyer, M.A. Philbert, and R. Kopelman, Optical nanosensors for chemical analysis inside single living cells. 1. Fabrication, characterization, and methods for intracellular delivery of PEBBLE sensors. Analytical Chemistry, 1999. 71(21): p. 4831-4836.
-
(1999)
Analytical Chemistry
, vol.71
, Issue.21
, pp. 4831-4836
-
-
Clark, H.A.1
Hoyer, M.2
Philbert, M.A.3
Kopelman, R.4
-
3
-
-
0033230266
-
Optical nanosensors for chemical analysis inside single living cells. 2. Sensors for pH and calcium and the intracellular applications of PEBBLE sensors
-
Clark, H.A., R. Kopelman, R, Tjalkens, and M.A. Philbert, Optical nanosensors for chemical analysis inside single living cells. 2. Sensors for pH and calcium and the intracellular applications of PEBBLE sensors. Analytical Chemistry, 1999. 71(21): p. 4837-4843.
-
(1999)
Analytical Chemistry
, vol.71
, Issue.21
, pp. 4837-4843
-
-
Clark, H.A.1
Kopelman, R.2
Tjalkens, R.3
Philbert, M.A.4
-
4
-
-
0001593946
-
Optochemical nanosensors and subcellular applications in living cells
-
Clark, H.A., M. Hoyer, S. Parus, M. Philbert, and R. Kopelman, Optochemical Nanosensors and Subcellular Applications in Living Cells. Mikrochimica Acta, 1999. 131: p. 121-128.
-
(1999)
Mikrochimica Acta
, vol.131
, pp. 121-128
-
-
Clark, H.A.1
Hoyer, M.2
Parus, S.3
Philbert, M.4
Kopelman, R.5
-
5
-
-
0035872320
-
Fluorescent nanosensors for intracellular chemical analysis: Decyl methacrylate liquid polymer matrix and ion-exchange-based potassium PEBBLE sensors with real-time application to viable rat C6 glioma cells
-
Brasuel, M., R. Kopelman, T.J. Miller, R. Tjalkens, and M.A. Philbert, Fluorescent Nanosensors for Intracellular Chemical Analysis: Decyl Methacrylate Liquid Polymer Matrix and Ion-Exchange-Based Potassium PEBBLE Sensors with Real-Time Application to Viable Rat C6 Glioma Cells. Analytical Chemistry, 2001. 73(10): p. 2221-2228.
-
(2001)
Analytical Chemistry
, vol.73
, Issue.10
, pp. 2221-2228
-
-
Brasuel, M.1
Kopelman, R.2
Miller, T.J.3
Tjalkens, R.4
Philbert, M.A.5
-
6
-
-
0035448944
-
A real-time ratiometric method for the determination of molecular oxygen inside living cells using sol-gel-based spherical optical nanosensors with applications to rat C6 glioma
-
Xu, H., J.W. Aylott, R. Kopelman, T.J. Miller, and M.A. Philbert, A Real-time Ratiometric Method for the Determination of Molecular Oxygen Inside Living Cells Using Sol-Gel-Based Spherical Optical Nanosensors with Applications to Rat C6 Glioma. Analytical Chemistry, 2001. 73(17): p. 4124-4133.
-
(2001)
Analytical Chemistry
, vol.73
, Issue.17
, pp. 4124-4133
-
-
Xu, H.1
Aylott, J.W.2
Kopelman, R.3
Miller, T.J.4
Philbert, M.A.5
-
7
-
-
0027560885
-
Optical sensors based on fluorescence anisotropy
-
Lippitch, M.E., Optical sensors based on fluorescence anisotropy, Sensors and Actuators B, 11 (1993) 499 - 502.
-
(1993)
Sensors and Actuators B
, vol.11
, pp. 499-502
-
-
Lippitch, M.E.1
-
8
-
-
0033557796
-
Anisotropy-based sensing with reference fluorophores
-
Lakowicz, J.R., Gryczynski, I., Grycznski, Z., and Dattelbaum, J.D., Anisotropy-Based Sensing with Reference Fluorophores, Anal. Biochem. 267 (1999) 397-405.
-
(1999)
Anal. Biochem.
, vol.267
, pp. 397-405
-
-
Lakowicz, J.R.1
Gryczynski, I.2
Grycznski, Z.3
Dattelbaum, J.D.4
-
9
-
-
0032794583
-
Polarization-based oxygen sensor
-
Gryczynski, I., Gryczynski, Z., Rao, G., and Lakowicz, J.R., Polarization-based oxygen sensor., Analyst 124 (1999) 1041-1044.
-
(1999)
Analyst
, vol.124
, pp. 1041-1044
-
-
Gryczynski, I.1
Gryczynski, Z.2
Rao, G.3
Lakowicz, J.R.4
-
10
-
-
0001606250
-
Expanded dynamic range of free zinc ion determination by fluorescence anisotropy
-
Thompson, R.B., Fierke, C.A, and. Maliwal, B.P., Expanded Dynamic Range of Free Zinc Ion Determination by Fluorescence Anisotropy., Anal. Chem. 70 (1998) 1749-1754.
-
(1998)
Anal. Chem.
, vol.70
, pp. 1749-1754
-
-
Thompson, R.B.1
Fierke, C.A.2
Maliwal, B.P.3
-
11
-
-
0032533884
-
Determination of picomolar concentrations of metal ions using fluorescence anisotropy: Biosensing with a "reagentless" enzyme transducer
-
Thompson, R.B., Fierke, C.A., Maliwal, B.P., Feliccia, V.L., and McCall, K., Determination of Picomolar Concentrations of Metal Ions Using Fluorescence Anisotropy: Biosensing with a "Reagentless" Enzyme Transducer., Anal. Chem. 70 (1998) 4717-4723.
-
(1998)
Anal. Chem.
, vol.70
, pp. 4717-4723
-
-
Thompson, R.B.1
Fierke, C.A.2
Maliwal, B.P.3
Feliccia, V.L.4
McCall, K.5
|