-
1
-
-
0041060584
-
Is smaller better? Scaling of characteristics with size of fibre-optic chemical and biochemical sensors
-
R. Kopelman, S. Dourado, Is smaller better? Scaling of characteristics with size of fibre-optic chemical and biochemical sensors, SPIE 2836 (1996) 2-11.
-
(1996)
SPIE
, vol.2836
, pp. 2-11
-
-
Kopelman, R.1
Dourado, S.2
-
3
-
-
0346172975
-
-
A.J. Bard (Ed.), Dekker, New York
-
R.M. Wightman, D.O. Wipf, in: A.J. Bard (Ed.),vol. 15, Dekker, New York, 1989.
-
(1989)
, vol.15
-
-
Wightman, R.M.1
Wipf, D.O.2
-
4
-
-
0026933081
-
Submicrometer intracellular chemical optical fibre sensors
-
W. Tan, Z.-Y. Shi, S. Smith, D. Birnbaum, R. Kopelman, Submicrometer intracellular chemical optical fibre sensors, Science 258 (1992) 778-781.
-
(1992)
Science
, vol.258
, pp. 778-781
-
-
Tan, W.1
Shi, Z.-Y.2
Smith, S.3
Birnbaum, D.4
Kopelman, R.5
-
5
-
-
0019017768
-
Fibre-optic pH probe for physiological use
-
J.I. Peterson, S.R. Goldstein, R.V. Fitzgerald, D.K. Buckhold, Fibre-optic pH probe for physiological use, Anal. Chem. 52 (1980) 864-869.
-
(1980)
Anal. Chem.
, vol.52
, pp. 864-869
-
-
Peterson, J.I.1
Goldstein, S.R.2
Fitzgerald, R.V.3
Buckhold, D.K.4
-
6
-
-
0030531102
-
Three-dimensional pH microprobing with an optically-manipulated fluorescent particle
-
K. Sasaki, Z.-Y. Shi, R. Kopelman, H. Mashura, Three-dimensional pH microprobing with an optically-manipulated fluorescent particle, Chem. Lett. (1996) 141-142.
-
(1996)
Chem. Lett.
, pp. 141-142
-
-
Sasaki, K.1
Shi, Z.-Y.2
Kopelman, R.3
Mashura, H.4
-
7
-
-
0030211070
-
Miniature sodium-selective ion-exchange optode with fluorescent pH chromoionophores and tunable dynamic range
-
M.R. Shortreed, E. Bakker, R. Kopelman, Miniature sodium-selective ion-exchange optode with fluorescent pH chromoionophores and tunable dynamic range, Anal. Chem. 68 (1996) 2656-2662.
-
(1996)
Anal. Chem.
, vol.68
, pp. 2656-2662
-
-
Shortreed, M.R.1
Bakker, E.2
Kopelman, R.3
-
8
-
-
0030686931
-
Development of fluorescent optical potassium-selective ion sensor with ratiometric response for intracellular applications
-
M.R. Shortreed, S. Dourado, R. Kopelman, Development of fluorescent optical potassium-selective ion sensor with ratiometric response for intracellular applications, Sensors and Actuators B 38-39 (1997) 8-12.
-
(1997)
Sensors and Actuators B
, vol.38-39
, pp. 8-12
-
-
Shortreed, M.R.1
Dourado, S.2
Kopelman, R.3
-
9
-
-
0031609252
-
Nitrite- and chloride-selective fluorescent nano-optodes and in vitro application to rat conceptuses
-
S.L.R. Barker, B.A. Thorsrud, R. Kopelman, Nitrite- and chloride-selective fluorescent nano-optodes and in vitro application to rat conceptuses, Anal. Chem. 70 (1998) 100-104.
-
(1998)
Anal. Chem.
, vol.70
, pp. 100-104
-
-
Barker, S.L.R.1
Thorsrud, B.A.2
Kopelman, R.3
-
10
-
-
0000572671
-
Characterisation of photopolymerised decyl methacrylate as a membrane matrix for ion-selective electrodes
-
T.M. Ambrose, M.E. Meyerhoff, Characterisation of photopolymerised decyl methacrylate as a membrane matrix for ion-selective electrodes, Electroanalysis 8 (1996) 1095-1100.
-
(1996)
Electroanalysis
, vol.8
, pp. 1095-1100
-
-
Ambrose, T.M.1
Meyerhoff, M.E.2
-
11
-
-
0032008554
-
Fiber-optic nitric oxide-selective biosensors and nanosensors
-
S.L.R.B. Barker, R. Kopelman, T.E. Meyer, M.A. Cusanovich, Fiber-optic nitric oxide-selective biosensors and nanosensors, Anal. Chem. 70 (1998) 971-976.
-
(1998)
Anal. Chem.
, vol.70
, pp. 971-976
-
-
Barker, S.L.R.B.1
Kopelman, R.2
Meyer, T.E.3
Cusanovich, M.A.4
|