메뉴 건너뛰기




Volumn 27, Issue 3, 2002, Pages 237-245

Real-time three-dimensional echocardiography for improved evaluation of diastolic function using volume-time curves

Author keywords

Diastole; Left ventricular function; Rapid filling rate; Real time 3 D echocardiography; Volume time curve

Indexed keywords

ARTICLE; BIOMEDICAL TECHNOLOGY ASSESSMENT; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; DIASTOLE; HEART FUNCTION; HEART LEFT VENTRICLE FUNCTION; HEART VOLUME; HUMAN; INTERMETHOD COMPARISON; MEDICAL DECISION MAKING; NUCLEAR MAGNETIC RESONANCE IMAGING; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TIME SERIES ANALYSIS; TRANSTHORACIC ECHOCARDIOGRAPHY; VOLUMETRY;

EID: 0036113833     PISSN: 03409937     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00059-002-2386-3     Document Type: Article
Times cited : (18)

References (35)
  • 8
    • 0027400173 scopus 로고
    • Assessment of left ventricular diastolic function in dilated cardiomyopathy with cine magnetic resonance imaging: Effect of an angiotensin converting enzyme inhibitor, benazepril
    • (1993) Am Heart J , vol.125 , pp. 171-178
    • Fujita, N.1    Hartiala, J.2    O'Sullivan, M.3
  • 17
    • 0033864612 scopus 로고    scopus 로고
    • Validation of real-time three-dimensional echocardiography for quantifying left ventricular volumes in the presence of a left ventricular aneurysm: In vitro and in vivo studies
    • (2000) J Am Coll Cardiol , vol.36 , pp. 900-907
    • Qin, J.X.1    Jones, M.2    Shiota, T.3
  • 20
    • 0027287727 scopus 로고
    • Pulmonary venous flow velocities recorded by transthoracic Doppler ultrasound: Relation to left ventricular diastolic pressures
    • (1993) J Am Coll Cardiol , vol.21 , pp. 1687-1696
    • Rossvoll, O.1    Hatle, L.K.2
  • 25
    • 0030060590 scopus 로고    scopus 로고
    • A new approach for evaluation of left ventricular diastolic function: Spatial and temporal analysis of left ventricular filling flow propagation by color M-mode Doppler echocardiography
    • (1996) J Am Coll Cardiol , vol.27 , pp. 365-371
    • Takatsuji, H.1    Mikami, T.2    Urasawa, K.3
  • 31
    • 0006207760 scopus 로고    scopus 로고
    • Mean rapid filling rate derived by real-time 3D echocardiography provides more robust identification of left ventricular diastolic dysfunction compared to peak filling rate
    • (2000) Eur J Echo , vol.1 , Issue.SUPPL. 2 , pp. 14
    • Zeidan, Z.1    Buck, T.2    Bartel, T.3    Erbel, R.4
  • 35
    • 0035859889 scopus 로고    scopus 로고
    • Heart failure with a normal ejection fraction: Is measurement of diastolic function necessary to make the diagnosis of diastolic heart failure?
    • (2001) Circulation , vol.104 , pp. 779-782
    • Zile, M.R.1    Gaasch, W.H.2    Carroll, J.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.