메뉴 건너뛰기




Volumn 137, Issue , 2002, Pages 233-244

Blood volume monitoring systems and biofeedback

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD VOLUME; HEMODYNAMICS; HUMAN; METHODOLOGY; MONITORING; PHYSIOLOGY; PSYCHOLOGICAL ASPECT; PSYCHOPHYSIOLOGY; RENAL REPLACEMENT THERAPY; REVIEW;

EID: 0036047432     PISSN: 03025144     EISSN: None     Source Type: Book Series    
DOI: 10.1159/000060219     Document Type: Article
Times cited : (4)

References (33)
  • 1
    • 0027515747 scopus 로고
    • Dialysis-induced hypotension: A fresh look at pathophysiology
    • Zucchelli P, Santoro A: Dialysis-induced hypotension: A fresh look at pathophysiology. Blood Purif 1993;11:85-98.
    • (1993) Blood Purif , vol.11 , pp. 85-98
    • Zucchelli, P.1    Santoro, A.2
  • 2
    • 0026078098 scopus 로고
    • Dialysis hypotension: A hemodynamic analysis
    • Daugirdas JT: Dialysis hypotension: A hemodynamic analysis. Kidney Int 1991;39:233-346.
    • (1991) Kidney Int , vol.39 , pp. 233-346
    • Daugirdas, J.T.1
  • 3
    • 0025142073 scopus 로고
    • Pathophysiology aspects of plasma volume preservation during dialysis and ultrafiltration
    • Klinkman H, Smeby IC (eds): Terminal Renal Failure: Therapeutic Problems, Possibilities and Potentials. Basel, Karger
    • Leunissen KML, Noordzig JC, Van Hoff JP: Pathophysiology aspects of plasma volume preservation during dialysis and ultrafiltration, in Klinkman H, Smeby IC (eds): Terminal Renal Failure: Therapeutic Problems, Possibilities and Potentials. Contrib Nephrol. Basel, Karger, 1990, vol 78, pp 201-211.
    • (1990) Contrib Nephrol , vol.78 , pp. 201-211
    • Leunissen, K.M.L.1    Noordzig, J.C.2    Van Hoff, J.P.3
  • 4
    • 0033833073 scopus 로고    scopus 로고
    • The impact of hemofiltration on the systemic cardiovascular response
    • Santoro A, Mancini E, Zucchelli P: The impact of hemofiltration on the systemic cardiovascular response. Nephrol Dial Transplant 2000;15(suppl 2):49-54.
    • (2000) Nephrol Dial Transplant , vol.15 , Issue.2 SUPPL. , pp. 49-54
    • Santoro, A.1    Mancini, E.2    Zucchelli, P.3
  • 7
    • 0019314109 scopus 로고
    • Recommended methods for measurement of red cell and plasma volume
    • International Committee for Standardisation in Haematology: Recommended methods for measurement of red cell and plasma volume. J Nucl Med 1980;21:793-800.
    • (1980) J Nucl Med , vol.21 , pp. 793-800
  • 9
    • 0023554479 scopus 로고
    • A new method of continuous hemoglobinometric measurement of blood volume during hemodialysis
    • Schallenberg U, Stiller S, Mann H: A new method of continuous hemoglobinometric measurement of blood volume during hemodialysis. Life Support Syst 1987;5:293-305.
    • (1987) Life Support Syst , vol.5 , pp. 293-305
    • Schallenberg, U.1    Stiller, S.2    Mann, H.3
  • 10
    • 0022916756 scopus 로고
    • Newly developed circulating blood volume monitoring system and its clinical application for measuring changes in blood volume during hemofiltration
    • Maeda K, Shinzato T, Yoshida F, et al: Newly developed circulating blood volume monitoring system and its clinical application for measuring changes in blood volume during hemofiltration. Artif Organs 1986;10:452-459.
    • (1986) Artif Organs , vol.10 , pp. 452-459
    • Maeda, K.1    Shinzato, T.2    Yoshida, F.3
  • 11
    • 0023700193 scopus 로고
    • Changes in blood parameters during hemodialysis as determined by conductivity measurements
    • De Vries PMJM, Kouw PM, Mejer JH: Changes in blood parameters during hemodialysis as determined by conductivity measurements. ASAIO Trans 1988;34:623-626.
    • (1988) ASAIO Trans , vol.34 , pp. 623-626
    • De Vries, P.M.J.M.1    Kouw, P.M.2    Mejer, J.H.3
  • 12
    • 0027243873 scopus 로고
    • A new optical technique for monitoring hematocrit and circulating blood volume: Its application in renal dialysis
    • Steuer RR, Harris DH, Conis JM: A new optical technique for monitoring hematocrit and circulating blood volume: Its application in renal dialysis. Dial Transplant 1993;22/5:260-265.
    • (1993) Dial Transplant , vol.22 , Issue.5 , pp. 260-265
    • Steuer, R.R.1    Harris, D.H.2    Conis, J.M.3
  • 13
    • 0025092293 scopus 로고
    • A blood protein monitor for the continuous measurement of blood volume changes during hemodialysis
    • Schneditz D, Pogglitsch H, Horina J, Binswanger U: A blood protein monitor for the continuous measurement of blood volume changes during hemodialysis. Kidney Int 1990;38:342-346.
    • (1990) Kidney Int , vol.38 , pp. 342-346
    • Schneditz, D.1    Pogglitsch, H.2    Horina, J.3    Binswanger, U.4
  • 14
    • 0027181839 scopus 로고
    • Continuous on-line optical absorbance recording of blood volume changes during hemodialysis
    • Mancini E, Santoro A, Spongano M, Paolini F, et al: Continuous on-line optical absorbance recording of blood volume changes during hemodialysis. Artif Organs 1993;17:691-694.
    • (1993) Artif Organs , vol.17 , pp. 691-694
    • Mancini, E.1    Santoro, A.2    Spongano, M.3    Paolini, F.4
  • 15
    • 0028972006 scopus 로고
    • Hemoscan™: A dialysis machine-integrated blood volume monitoring
    • Paolini F, Mancini E, Bosetto A, Santoro A: Hemoscan™: A dialysis machine-integrated blood volume monitoring. Int J Artif Organs 1995;18:487-494.
    • (1995) Int J Artif Organs , vol.18 , pp. 487-494
    • Paolini, F.1    Mancini, E.2    Bosetto, A.3    Santoro, A.4
  • 16
    • 0021734917 scopus 로고
    • Model prediction of plasma volume change induced by hemodialysis
    • Kimura G, Van Stone JC, Baven J: Model prediction of plasma volume change induced by hemodialysis. J Lab Clin Med 1984;104:932-938.
    • (1984) J Lab Clin Med , vol.104 , pp. 932-938
    • Kimura, G.1    Van Stone, J.C.2    Baven, J.3
  • 17
    • 0026481995 scopus 로고
    • Nature and rate of vascular refilling during hemodialysis and ultrafiltration
    • Schneditz D, Roob J, Osvald M, Pogglitsch H, et al: Nature and rate of vascular refilling during hemodialysis and ultrafiltration. Kidney Int 1992;42:1425-1433.
    • (1992) Kidney Int , vol.42 , pp. 1425-1433
    • Schneditz, D.1    Roob, J.2    Osvald, M.3    Pogglitsch, H.4
  • 18
    • 0030637697 scopus 로고    scopus 로고
    • Clinical significance of intradialytic blood volume monitoring
    • Santoro A, Mancini E: Clinical significance of intradialytic blood volume monitoring. Int J Artif Organs 1997;20:1-6.
    • (1997) Int J Artif Organs , vol.20 , pp. 1-6
    • Santoro, A.1    Mancini, E.2
  • 19
    • 0029769662 scopus 로고    scopus 로고
    • A study on regulating factors of plasma refilling during hemodialysis
    • Ilimura O, Tabei L, Nagashima H, Asano K: A study on regulating factors of plasma refilling during hemodialysis. Nephron 1996;74:19-25.
    • (1996) Nephron , vol.74 , pp. 19-25
    • Ilimura, O.1    Tabei, L.2    Nagashima, H.3    Asano, K.4
  • 20
    • 0021720325 scopus 로고
    • Plasma volume recovery after ultrafiltration in patients with chronic renal failure
    • Koomans HA, Geers AB, Meers EJD: Plasma volume recovery after ultrafiltration in patients with chronic renal failure. Kidney Int 1984;26:848-854.
    • (1984) Kidney Int , vol.26 , pp. 848-854
    • Koomans, H.A.1    Geers, A.B.2    Meers, E.J.D.3
  • 21
    • 0029012240 scopus 로고
    • Influence of hydration state on plasma volume changes during ultrafiltration
    • Wizeman V, Leibinger A, Mueller K, Nilson A: Influence of hydration state on plasma volume changes during ultrafiltration. Artif Organs 1995;19:416-419.
    • (1995) Artif Organs , vol.19 , pp. 416-419
    • Wizeman, V.1    Leibinger, A.2    Mueller, K.3    Nilson, A.4
  • 22
    • 0028464341 scopus 로고
    • Hematocrit as an indicator of blood volume and predictor of intradialytic morbid events
    • Steuer RR, Leypolt JK, Cheung AK: Hematocrit as an indicator of blood volume and predictor of intradialytic morbid events. ASAIO J 1994;40:M691-M696.
    • (1994) ASAIO J , vol.40
    • Steuer, R.R.1    Leypolt, J.K.2    Cheung, A.K.3
  • 25
    • 0028464338 scopus 로고
    • Automatic control of blood volume trends during hemodialysis
    • Santoro A, Mancini E, Paolini F, Zucchelli P: Automatic control of blood volume trends during hemodialysis. ASAIO J 1994;40:M419-M422.
    • (1994) ASAIO J , vol.40
    • Santoro, A.1    Mancini, E.2    Paolini, F.3    Zucchelli, P.4
  • 26
    • 0023162392 scopus 로고
    • Effect of dialysate composition on intercompartmental fluid shift
    • Fleming SJ, Wilkinson JS, Greenwood RN, Aldridge C, et al: Effect of dialysate composition on intercompartmental fluid shift. Kidney Int 1987;32:267-273.
    • (1987) Kidney Int , vol.32 , pp. 267-273
    • Fleming, S.J.1    Wilkinson, J.S.2    Greenwood, R.N.3    Aldridge, C.4
  • 27
    • 0020417990 scopus 로고
    • Preservation of plasma volume during hemodialysis depends on dialysate osmolality
    • Swartz RD, Somermeyer MG, Hsu CH: Preservation of plasma volume during hemodialysis depends on dialysate osmolality. Am J Nephrol 1982;2:189-194.
    • (1982) Am J Nephrol , vol.2 , pp. 189-194
    • Swartz, R.D.1    Somermeyer, M.G.2    Hsu, C.H.3
  • 30
  • 31
    • 0000422483 scopus 로고    scopus 로고
    • Effects of automatic blood volume control on the cardiovascular stability of hypotension-prone hemodialysis patients
    • Santoro A, Mancini E: Effects of automatic blood volume control on the cardiovascular stability of hypotension-prone hemodialysis patients. J Am Soc Nephrol 1998;9:1364.
    • (1998) J Am Soc Nephrol , vol.9 , pp. 1364
    • Santoro, A.1    Mancini, E.2
  • 32
    • 0035145183 scopus 로고    scopus 로고
    • Efficacy and safety of hemodialysis treatment with the Hemocontrol biofeedback system: A prospective medium-term study
    • Basile C, Giordano R, Vernaglione L, Montanaro A, et al: Efficacy and safety of hemodialysis treatment with the Hemocontrol biofeedback system: A prospective medium-term study. Nephrol Dial Transplant 2001;16:328-334.
    • (2001) Nephrol Dial Transplant , vol.16 , pp. 328-334
    • Basile, C.1    Giordano, R.2    Vernaglione, L.3    Montanaro, A.4
  • 33
    • 0033864894 scopus 로고    scopus 로고
    • Impact of biofeedback-induced cardiovascular stability on hemodialysis tolerance and efficiency
    • Ronco C, Brendolan A, Milan M, Rodeghiero MP, et al: Impact of biofeedback-induced cardiovascular stability on hemodialysis tolerance and efficiency. Kidney Int 2000;58:800-808.
    • (2000) Kidney Int , vol.58 , pp. 800-808
    • Ronco, C.1    Brendolan, A.2    Milan, M.3    Rodeghiero, M.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.