메뉴 건너뛰기




Volumn 137, Issue , 2002, Pages 129-137

Optimal use of hemodialyzers

Author keywords

[No Author keywords available]

Indexed keywords

UREA;

EID: 0036043723     PISSN: 03025144     EISSN: None     Source Type: Book Series    
DOI: 10.1159/000060239     Document Type: Article
Times cited : (9)

References (13)
  • 1
    • 0035221369 scopus 로고    scopus 로고
    • K/DOQI clinical practice guidelines for hemodialysis adequacy, 2000
    • National Kidney Foundation: K/DOQI clinical practice guidelines for hemodialysis adequacy, 2000. Am J Kidney Dis 2001;37(suppl 1):S7-S64.
    • (2001) Am J Kidney Dis , vol.37 , Issue.1 SUPPL.
  • 2
    • 0013990616 scopus 로고
    • Operating parameters and performance criteria for hemodialyzers and other membrane-separation devices
    • Michaels AS: Operating parameters and performance criteria for hemodialyzers and other membrane-separation devices. Trans Am Soc Artif Intern Organs 1966;12:387-392.
    • (1966) Trans Am Soc Artif Intern Organs , vol.12 , pp. 387-392
    • Michaels, A.S.1
  • 3
    • 54249093884 scopus 로고    scopus 로고
    • Simultaneous estimation of delivered blood flow (Qb) and in-vivo urea mass transfer coefficient (KoA) from the cross-dialyzer extraction ratio (ER)
    • The HEMO Study Group
    • Depner T, Greene T, Daugirdas J, Gotch F, Kusek J, Leypoldt J, McGillicuddy JR: Simultaneous estimation of delivered blood flow (Qb) and in-vivo urea mass transfer coefficient (KoA) from the cross-dialyzer extraction ratio (ER) (abstract). The HEMO Study Group. J Am Soc Nephrol 2000;11:317A-318A.
    • (2000) J Am Soc Nephrol , vol.11
    • Depner, T.1    Greene, T.2    Daugirdas, J.3    Gotch, F.4    Kusek, J.5    Leypoldt, J.6    McGillicuddy, J.R.7
  • 5
    • 0030988709 scopus 로고    scopus 로고
    • Hemodialyzer mass transfer-area coefficients for urea increase at high dialysate flow rates
    • The Hemodialysis (HEMO) Study Group
    • Leypoldt JK, Cheung AK, Agodoa LY, Daugirdas JT, Greene T, Keshaviah PR: Hemodialyzer mass transfer-area coefficients for urea increase at high dialysate flow rates. The Hemodialysis (HEMO) Study Group. Kidney Int 1997;51:2013-2017.
    • (1997) Kidney Int , vol.51 , pp. 2013-2017
    • Leypoldt, J.K.1    Cheung, A.K.2    Agodoa, L.Y.3    Daugirdas, J.T.4    Greene, T.5    Keshaviah, P.R.6
  • 6
    • 0035151511 scopus 로고    scopus 로고
    • Increasing dialysate flow rate increases dialyzer urea mass transfer-area coefficients during clinical use
    • Ouseph R, Ward RA: Increasing dialysate flow rate increases dialyzer urea mass transfer-area coefficients during clinical use. Am J Kidney Dis 2001;37:316-320.
    • (2001) Am J Kidney Dis , vol.37 , pp. 316-320
    • Ouseph, R.1    Ward, R.A.2
  • 7
    • 0025457138 scopus 로고
    • Pressure effects on roller pump blood flow during hemodialysis
    • Depner TA, Rizwan S, Stasi TA: Pressure effects on roller pump blood flow during hemodialysis. ASAIO Trans 1990;36:M456-M459.
    • (1990) ASAIO Trans , vol.36
    • Depner, T.A.1    Rizwan, S.2    Stasi, T.A.3
  • 8
    • 0002405830 scopus 로고    scopus 로고
    • Physiologic principles and urea kinetic modeling
    • Daugirdas JT, Blake PG, Ing TS (eds): Philadelphia, Lippincott Williams & Wilkins
    • Daugirdas JT, Van Stone JC: Physiologic principles and urea kinetic modeling; in Daugirdas JT, Blake PG, Ing TS (eds): Handbook of Dialysis, ed 3. Philadelphia, Lippincott Williams & Wilkins, 2001, pp 15-45.
    • (2001) Handbook of Dialysis, Ed 3 , pp. 15-45
    • Daugirdas, J.T.1    Van Stone, J.C.2
  • 9
    • 0032895253 scopus 로고    scopus 로고
    • Blood flow rate: An important determinant of urea clearance and delivered Kt/V
    • Ward RA: Blood flow rate: An important determinant of urea clearance and delivered Kt/V. Adv Ren Replace Ther 1999;6:75-79.
    • (1999) Adv Ren Replace Ther , vol.6 , pp. 75-79
    • Ward, R.A.1
  • 10
    • 0022504129 scopus 로고
    • Clearance of a dialyzer under varying operating conditions
    • Sigdell JE, Tersteegen B: Clearance of a dialyzer under varying operating conditions. Artif Organs 1986;10:219-225.
    • (1986) Artif Organs , vol.10 , pp. 219-225
    • Sigdell, J.E.1    Tersteegen, B.2
  • 11
    • 0028785457 scopus 로고
    • Studies concerning the optimization of dialysate consumption
    • Sigdell JE, Tersteegen B: Studies concerning the optimization of dialysate consumption. Nephron 1995;71:401-406.
    • (1995) Nephron , vol.71 , pp. 401-406
    • Sigdell, J.E.1    Tersteegen, B.2
  • 12
    • 0030933211 scopus 로고    scopus 로고
    • The relationship of recirculation to access blood flow
    • Besarab A, Sherman R: The relationship of recirculation to access blood flow. Am J Kidney Dis 1997;29:223-229.
    • (1997) Am J Kidney Dis , vol.29 , pp. 223-229
    • Besarab, A.1    Sherman, R.2
  • 13
    • 0034002191 scopus 로고    scopus 로고
    • Solute fluxes in different treatment modalities
    • Leypoldt JK: Solute fluxes in different treatment modalities. Nephrol Dial Transplant 2000;15(suppl 1):3-9.
    • (2000) Nephrol Dial Transplant , vol.15 , Issue.1 SUPPL. , pp. 3-9
    • Leypoldt, J.K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.