Volumn 27, Issue 1-2, 2002, Pages 177-182
|
A new HPLC method to determine Donepezil hydrochloride in tablets
|
Author keywords
Assay; Donepezil hydrochloride; HPLC; Validation
|
Indexed keywords
BUFFER;
DONEPEZIL;
METHANOL;
TRIETHYLAMINE;
ACCURACY;
ALZHEIMER DISEASE;
ANALYTIC METHOD;
ARTICLE;
COLUMN CHROMATOGRAPHY;
DEMENTIA;
DRUG DETERMINATION;
DRUG RETENTION;
DRUG SELECTIVITY;
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY;
HUMAN;
PRIORITY JOURNAL;
QUALITY CONTROL;
STATISTICAL ANALYSIS;
TABLET;
VALIDATION PROCESS;
CHROMATOGRAPHY, HIGH PRESSURE LIQUID;
DRUG STABILITY;
INDANS;
PIPERIDINES;
REPRODUCIBILITY OF RESULTS;
TABLETS;
|
EID: 0036027826
PISSN: 07317085
EISSN: None
Source Type: Journal
DOI: 10.1016/S0731-7085(01)00499-X Document Type: Article |
Times cited : (56)
|
References (7)
|