메뉴 건너뛰기




Volumn 4508, Issue , 2001, Pages 15-19

A comparative study of CsI(Tl) screens for macromolecular crystallography

Author keywords

CCDs; Crystallography; CsI(Tl) scintillator; Gd2O2S (GOS); High resolution x ray sensor; Synchrotron instrumentation; X ray diffraction; X ray imaging

Indexed keywords

CHARGE COUPLED DEVICES; FABRICATION; IMAGE SENSORS; IMAGING SYSTEMS; PHOSPHORS; RADIATION DETECTORS; X RAY CRYSTALLOGRAPHY; X RAY DIFFRACTION ANALYSIS;

EID: 0035764799     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.450790     Document Type: Conference Paper
Times cited : (13)

References (16)
  • 1
    • 0031566962 scopus 로고    scopus 로고
    • Time resolved synchrotron x-ray "footprinting"
    • Sclavi, B. et al. "Time resolved synchrotron X-ray "footprinting"" J Mol Biol Vol. 226 No. 1 pp. 144-59 (1997).
    • (1997) J Mol Biol , vol.226 , Issue.1 , pp. 144-159
    • Sclavi, B.1
  • 2
    • 0031541521 scopus 로고    scopus 로고
    • Time-resolved protein crystallography with large-angle oscillations: An application of a protein data-collection system using the Weissenberg technique and a large-format imaging plate
    • Kamiya, N. et al. "Time-resolved protein crystallography with large-angle oscillations: an application of a protein data-collection system using the Weissenberg technique and a large-format imaging plate" J. Synch. Radiat. Vol. 4 No. 1 pp. 14-16 (1997).
    • (1997) J. Synch. Radiat. , vol.4 , Issue.1 , pp. 14-16
    • Kamiya, N.1
  • 3
    • 0030833143 scopus 로고    scopus 로고
    • Synchrotron radiation applications to macromolecular Crystallography
    • Moffat, K. et al. "Synchrotron radiation applications to macromolecular Crystallography" Curr. Opin. Struc. Biol. Vol. 7 No. 5 pp. 689-96 (1997).
    • (1997) Curr. Opin. Struc. Biol. , vol.7 , Issue.5 , pp. 689-696
    • Moffat, K.1
  • 4
    • 0028081493 scopus 로고
    • X-x-ray diffraction measurements of the extensibility of actin and myosin filaments in contracting muscle
    • Huxley, et.al., "X-x-ray Diffraction Measurements of the Extensibility of Actin and Myosin Filaments in Contracting Muscle," Biophysical Journal, Vol. 67, (1994).
    • (1994) Biophysical Journal , vol.67
    • Huxley1
  • 5
    • 0033480641 scopus 로고    scopus 로고
    • A multiple-CCD x-ray detector and its basic characterization
    • Suzuki, M. et al. "A multiple-CCD X-ray detector and its basic characterization," J. Synch. Radiat. Pt. 1 Vol. 6 pp. 6-18 (1999).
    • (1999) J. Synch. Radiat. Pt. 1 , vol.6 , pp. 6-18
    • Suzuki, M.1
  • 6
    • 0000722386 scopus 로고    scopus 로고
    • Charge-coupled device/fiber optic taper array x-ray detector for protein crystallography
    • Naday, I. Et al. "Charge-coupled device/fiber optic taper array X-ray detector for protein crystallography," Optical Eng. Vol. 37 No. 4 pp. 1235-1244 (1998).
    • (1998) Optical Eng. , vol.37 , Issue.4 , pp. 1235-1244
    • Naday, I.1
  • 10
    • 0031273818 scopus 로고    scopus 로고
    • Amorphous silicon, semiconductor x-ray converter detectors for protein crystallography
    • Ross, S. et al. "Amorphous silicon, semiconductor X-ray converter detectors for protein crystallography" Nucl. Inst. And Meth. in Phys. Res., Sec. A Vol. 1 pp. 38-50 (1997).
    • (1997) Nucl. Inst. And Meth. in Phys. Res., Sec. A , vol.1 , pp. 38-50
    • Ross, S.1
  • 14
    • 0031252149 scopus 로고    scopus 로고
    • CCD based high resolution non-destructive testing system for industrial applications
    • Nagarkar, V.V., Vasile, S., Gothoskar, P., Gordon, J.S. and Gupta, T.K., "CCD Based High Resolution Non-destructive Testing System for Industrial Applications", Appl. Radiat. Isot., Vol. 48, (1459-1465), 1997.
    • (1997) Appl. Radiat. Isot. , vol.48 , pp. 1459-1465
    • Nagarkar, V.V.1    Vasile, S.2    Gothoskar, P.3    Gordon, J.S.4    Gupta, T.K.5
  • 15
    • 0000288651 scopus 로고    scopus 로고
    • CCD based high resolution digital radiography system for non destructive evaluation
    • Nagarkar, V.V., et. al., "CCD Based High Resolution Digital Radiography System for Non Destructive Evaluation" IEEE Trans. Nuc. Sci., 44, No. 3, (885-889), 1997.
    • (1997) IEEE Trans. Nuc. Sci. , vol.44 , Issue.3 , pp. 885-889
    • Nagarkar, V.V.1
  • 16
    • 0029227091 scopus 로고
    • Improved x-ray converters for CCD-based crystallography detectors
    • X-ray and Ultraviolet Sensors and Applications
    • Nagarkar, V.V.; Gordon, J.S.; Vasile, S.; Xie, J.; and Phillips, W.C. "Improved X-Ray Converters for CCD-based Crystallography Detectors," SPIE Vol. 2519, X-ray and Ultraviolet Sensors and Applications, p.2-11, (1995).
    • (1995) SPIE , vol.2519 , pp. 2-11
    • Nagarkar, V.V.1    Gordon, J.S.2    Vasile, S.3    Xie, J.4    Phillips, W.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.