메뉴 건너뛰기




Volumn 16, Issue 4, 2001, Pages 547-556

Dimensional Accuracy and Retentive Strength of a Retrievable Cement-retained Implant-supported Prosthesis

Author keywords

Dental cement; Dental implants; Dental materials; Fixed partial denture; Implant supported dental prosthesis; Prosthesis fitting

Indexed keywords

BISPHENOL A BIS(2 HYDROXYPROPYL) ETHER DIMETHACRYLATE; GOLD ALLOY; RESIN CEMENT; WAX;

EID: 0035408517     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (17)

References (60)
  • 1
  • 2
    • 0030237874 scopus 로고    scopus 로고
    • Prosthesis misfit and marginal bone loss in edentulous implant patients
    • Jemt T, Book K. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants 1996;11(5):620-625.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , Issue.5 , pp. 620-625
    • Jemt, T.1    Book, K.2
  • 3
    • 0030277405 scopus 로고    scopus 로고
    • The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit
    • Carr AB, Gerard DA, Larsen PE. The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit. J Prosthet Dent 1996;76(5): 500-509.
    • (1996) J Prosthet Dent , vol.76 , Issue.5 , pp. 500-509
    • Carr, A.B.1    Gerard, D.A.2    Larsen, P.E.3
  • 4
    • 0030090665 scopus 로고    scopus 로고
    • On the influence of superstructure connection on implant preload: A methodological and clinical study
    • Smedberg JI, Nilner K, Rangert B, Svensson SA, Glantz SA. On the influence of superstructure connection on implant preload: A methodological and clinical study. Clin Oral Implants Res 1996;7(1):55-63.
    • (1996) Clin Oral Implants Res , vol.7 , Issue.1 , pp. 55-63
    • Smedberg, J.I.1    Nilner, K.2    Rangert, B.3    Svensson, S.A.4    Glantz, S.A.5
  • 5
    • 0026218667 scopus 로고
    • Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup
    • Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 1991;6(3):270-276.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , Issue.3 , pp. 270-276
    • Jemt, T.1
  • 6
    • 0027015903 scopus 로고
    • A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects
    • Naert I, Quirynen M, van Steenberghe D, Darius P. A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects. J Prosthet Dent 1992; 68(6):949-956.
    • (1992) J Prosthet Dent , vol.68 , Issue.6 , pp. 949-956
    • Naert, I.1    Quirynen, M.2    Van Steenberghe, D.3    Darius, P.4
  • 8
    • 0028185282 scopus 로고
    • Prosthodontic complications in osseointegrated dental implant treatment
    • Carlson B, Carlsson GE. Prosthodontic complications in osseointegrated dental implant treatment. Int J Oral Maxillofac Implants 1994;9(1):90-94.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , Issue.1 , pp. 90-94
    • Carlson, B.1    Carlsson, G.E.2
  • 9
    • 0028390316 scopus 로고
    • Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years
    • Kallus T, Bessing C. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 1994; 9(2):169-178.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , Issue.2 , pp. 169-178
    • Kallus, T.1    Bessing, C.2
  • 10
    • 0025032861 scopus 로고
    • Complications, supplementary treatment, and maintenance in edentulous arches with implant-supported fixed prostheses
    • Johansson G, Palmqvist S. Complications, supplementary treatment, and maintenance in edentulous arches with implant-supported fixed prostheses. Int J Prosthodont 1990; 3(1):89-92.
    • (1990) Int J Prosthodont , vol.3 , Issue.1 , pp. 89-92
    • Johansson, G.1    Palmqvist, S.2
  • 12
    • 0026921977 scopus 로고
    • Loads and designs of screw joints for single crowns supported by osseointegrated implants
    • Jörnéus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992;7(3):353-359.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , Issue.3 , pp. 353-359
    • Jörnéus, L.1    Jemt, T.2    Carlsson, L.3
  • 13
    • 0033088969 scopus 로고    scopus 로고
    • Strategies to achieve fit in implant prosthodontics: A review of the literature
    • Wee AG, Aquilino SA, Schneider RL. Strategies to achieve fit in implant prosthodontics: A review of the literature. Int J Prosthodont 1999;12(2):167-178.
    • (1999) Int J Prosthodont , vol.12 , Issue.2 , pp. 167-178
    • Wee, A.G.1    Aquilino, S.A.2    Schneider, R.L.3
  • 14
    • 0018980257 scopus 로고
    • The measurement of distortion: Concluding remarks
    • Nicholls JI. The measurement of distortion: Concluding remarks. J Prosthet Dent 1980;43(2):218-223.
    • (1980) J Prosthet Dent , vol.43 , Issue.2 , pp. 218-223
    • Nicholls, J.I.1
  • 15
    • 0017496465 scopus 로고
    • The measurement of distortion: Theoretical considerations
    • Nicholls JI. The measurement of distortion: Theoretical considerations. J Prosthet Dent 1977;37(5):578-586.
    • (1977) J Prosthet Dent , vol.37 , Issue.5 , pp. 578-586
    • Nicholls, J.I.1
  • 16
    • 0017950083 scopus 로고
    • The measurement of distortion: Mathematical considerations
    • Nicholls JI. The measurement of distortion: Mathematical considerations. J Prosthet Dent 1978;9(3):339-343.
    • (1978) J Prosthet Dent , vol.9 , Issue.3 , pp. 339-343
    • Nicholls, J.I.1
  • 18
    • 0026217692 scopus 로고
    • Mandibular deformation in subjects with osseointegrated implants
    • Hobkirk JA, Schwab J. Mandibular deformation in subjects with osseointegrated implants. Int J Oral Maxillofac Implants 1991;6(3):319-328.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , Issue.3 , pp. 319-328
    • Hobkirk, J.A.1    Schwab, J.2
  • 19
    • 0027739563 scopus 로고
    • Evaluation of master cast techniques for multiple abutment implant prostheses
    • Vigolo P, Millstein PL. Evaluation of master cast techniques for multiple abutment implant prostheses. Int J Oral Maxillofac Implants 1993;8(4):439-446.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , Issue.4 , pp. 439-446
    • Vigolo, P.1    Millstein, P.L.2
  • 21
    • 0030326118 scopus 로고    scopus 로고
    • The accuracy of implant verification casts compared with casts produced from a rigid transfer coping technique
    • Carr AB, Master J. The accuracy of implant verification casts compared with casts produced from a rigid transfer coping technique. J Prosthodont 1996;5(4):248-252.
    • (1996) J Prosthodont , vol.54 , pp. 248-252
    • Carr, A.B.1    Master, J.2
  • 22
    • 0025622921 scopus 로고
    • The accuracy of implant master casts constructed from transfer impressions
    • Humphries RM, Yaman P, Bloem TJ. The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants 1990;5(4):331-336.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , Issue.4 , pp. 331-336
    • Humphries, R.M.1    Yaman, P.2    Bloem, T.J.3
  • 23
    • 0142111323 scopus 로고
    • The accuracy of three implant impression techniques: A 3-dimensional analysis
    • Phillips KM, Nicholls JI, Ma T. The accuracy of three implant impression techniques: A 3-dimensional analysis. Int J Oral Maxillofac Implants 1994;9:533-540.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 533-540
    • Phillips, K.M.1    Nicholls, J.I.2    Ma, T.3
  • 24
    • 0027622922 scopus 로고
    • Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials
    • Liou AD, Nicholls JI, Yuodelis RA, Brudvik JS. Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials. Int J Prosthodont 1993; 6(4):377-383.
    • (1993) Int J Prosthodont , vol.6 , Issue.4 , pp. 377-383
    • Liou, A.D.1    Nicholls, J.I.2    Yuodelis, R.A.3    Brudvik, J.S.4
  • 25
    • 0025412492 scopus 로고
    • An evaluation of impression techniques for osseointegrated implants
    • Spector MR, Donovan TE, Nicholls JI. An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 1990;63(4):444-447.
    • (1990) J Prosthet Dent , vol.63 , Issue.4 , pp. 444-447
    • Spector, M.R.1    Donovan, T.E.2    Nicholls, J.I.3
  • 26
    • 0027620268 scopus 로고
    • The accuracy of six impression techniques for osseointegrated implants
    • Barrett MG, De Rijk WG, Burgess JO. The accuracy of six impression techniques for osseointegrated implants. J Prosthodont 1993;2(2):75-82.
    • (1993) J Prosthodont , vol.2 , Issue.2 , pp. 75-82
    • Barrett, M.G.1    De Rijk, W.G.2    Burgess, J.O.3
  • 27
    • 0026311384 scopus 로고
    • Comparison of impression techniques for a five-implant mandibular model
    • Carr AB. Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implants 1991;6(4):448-455.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , Issue.4 , pp. 448-455
    • Carr, A.B.1
  • 29
    • 0027597615 scopus 로고
    • Evaluation of three impression techniques for osseointegrated oral implants
    • Inturregui JA, Aquilino SA, Ryther JS, Lund PS. Evaluation of three impression techniques for osseointegrated oral implants. J Prosthet Dent 1993;69(5):503-509.
    • (1993) J Prosthet Dent , vol.69 , Issue.5 , pp. 503-509
    • Inturregui, J.A.1    Aquilino, S.A.2    Ryther, J.S.3    Lund, P.S.4
  • 30
    • 0033182713 scopus 로고    scopus 로고
    • Distortion of three-unit implant frameworks during casting, soldering, and simulated porcelain firings
    • Zervas PJ, Papazoglou E, Beck FM, Carr AB. Distortion of three-unit implant frameworks during casting, soldering, and simulated porcelain firings. J Prosthodont 1999;8: 171-179.
    • (1999) J Prosthodont , vol.8 , pp. 171-179
    • Zervas, P.J.1    Papazoglou, E.2    Beck, F.M.3    Carr, A.B.4
  • 31
    • 0027563662 scopus 로고
    • Full-arch implant framework casting accuracy: Preliminary in vitro observation for in vivo testing
    • Carr AB, Stewart RB. Full-arch implant framework casting accuracy: Preliminary in vitro observation for in vivo testing. J Prosthodont 1993;2(1):2-8.
    • (1993) J Prosthodont , vol.2 , Issue.1 , pp. 2-8
    • Carr, A.B.1    Stewart, R.B.2
  • 32
    • 0026953052 scopus 로고
    • Accuracy of the acrylic resin pattern for the implant-retained prosthesis
    • Ness EM, Nicholls JI, Rubenstein JE, Smith DE. Accuracy of the acrylic resin pattern for the implant-retained prosthesis. Int J Prosthodont 1992;5(6):542-549.
    • (1992) Int J Prosthodont , vol.5 , Issue.6 , pp. 542-549
    • Ness, E.M.1    Nicholls, J.I.2    Rubenstein, J.E.3    Smith, D.E.4
  • 33
    • 0027623331 scopus 로고
    • Three-dimensional analysis of the casting accuracy of one-piece, osseointegrated implant-retained prostheses
    • Tan KB, Rubenstein JE, Nicholls JI, Yuodelis RA. Three-dimensional analysis of the casting accuracy of one-piece, osseointegrated implant-retained prostheses. Int J Prosthodont 1993;6(4):346-363.
    • (1993) Int J Prosthodont , vol.6 , Issue.4 , pp. 346-363
    • Tan, K.B.1    Rubenstein, J.E.2    Nicholls, J.I.3    Yuodelis, R.A.4
  • 34
    • 0029377214 scopus 로고
    • Accuracy of implant-supported prostheses in the edentulous jaw: Analysis of precision of fit between cast gold-alloy frameworks and master casts by means of a three-dimensional photogrammetric technique
    • Jemt T, Lie A. Accuracy of implant-supported prostheses in the edentulous jaw: Analysis of precision of fit between cast gold-alloy frameworks and master casts by means of a three-dimensional photogrammetric technique. Clin Oral Implants Res 1995;6(3):172-180.
    • (1995) Clin Oral Implants Res , vol.6 , Issue.3 , pp. 172-180
    • Jemt, T.1    Lie, A.2
  • 35
    • 0032611035 scopus 로고    scopus 로고
    • Laser-welded titanium frameworks for implant-supported fixed prostheses: A 5-year report
    • Bergendal B, Palmqvist S. Laser-welded titanium frameworks for implant-supported fixed prostheses: A 5-year report. Int J Oral Maxillofac Implants 1999;14(1):69-71.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , Issue.1 , pp. 69-71
    • Bergendal, B.1    Palmqvist, S.2
  • 36
    • 0027018790 scopus 로고
    • Fixed implant-supported prostheses with welded titanium frameworks
    • Jemt T, Linden B. Fixed implant-supported prostheses with welded titanium frameworks. Int J Periodontics Restorative Dent 1992;12(3):177-184.
    • (1992) Int J Periodontics Restorative Dent , vol.12 , Issue.3 , pp. 177-184
    • Jemt, T.1    Linden, B.2
  • 37
    • 0028457325 scopus 로고
    • Passive fit of implant-retained prosthetic superstructures improved by electric discharge machining
    • Linehan AD, Windeler AS. Passive fit of implant-retained prosthetic superstructures improved by electric discharge machining. J Prosthodont 1994;3(2):88-95.
    • (1994) J Prosthodont , vol.3 , Issue.2 , pp. 88-95
    • Linehan, A.D.1    Windeler, A.S.2
  • 38
    • 0026832539 scopus 로고
    • Prostheses fabrication using electrical discharge machining
    • Van Rockel NB. Prostheses fabrication using electrical discharge machining. Int J Oral Maxillofac Implants 1992;7: 56-61.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 56-61
    • Van Rockel, N.B.1
  • 39
    • 0031066345 scopus 로고    scopus 로고
    • Correcting the fit of implant-retained restorations by electric discharge machining
    • Evans DB. Correcting the fit of implant-retained restorations by electric discharge machining. J Prosthet Dent 1997; 77(2):212-215.
    • (1997) J Prosthet Dent , vol.77 , Issue.2 , pp. 212-215
    • Evans, D.B.1
  • 41
    • 0031301642 scopus 로고    scopus 로고
    • Fit of implant frameworks fabricated by different techniques
    • Riedy SJ, Lang BR, Lang BE. Fit of implant frameworks fabricated by different techniques. J Prosthet Dent 1997; 78(6):596-604.
    • (1997) J Prosthet Dent , vol.78 , Issue.6 , pp. 596-604
    • Riedy, S.J.1    Lang, B.R.2    Lang, B.E.3
  • 42
    • 0028390303 scopus 로고
    • Photogrammetric measurements of implant positions. Description of a technique to determine the fit between implants and superstructures
    • Lie A, Jemt T. Photogrammetric measurements of implant positions. Description of a technique to determine the fit between implants and superstructures. Clin Oral Implants Res 1994;5(1):30-36.
    • (1994) Clin Oral Implants Res , vol.5 , Issue.1 , pp. 30-36
    • Lie, A.1    Jemt, T.2
  • 43
    • 0030097958 scopus 로고    scopus 로고
    • In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw
    • Jemt T. In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw. Int J Oral Maxillofac Implants 1996;11(2):151-158.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , Issue.2 , pp. 151-158
    • Jemt, T.1
  • 44
    • 0030226140 scopus 로고    scopus 로고
    • Comparison of strains transferred to a bone simulant between as-cast and post-soldered implant frameworks for a five-implant-supported fixed prosthesis
    • Clelland NL, Carr AB, Gilat A. Comparison of strains transferred to a bone simulant between as-cast and post-soldered implant frameworks for a five-implant-supported fixed prosthesis. J Prosthodont 1996;5(3):193-200.
    • (1996) J Prosthodont , vol.5 , Issue.3 , pp. 193-200
    • Clelland, N.L.1    Carr, A.B.2    Gilat, A.3
  • 46
    • 0021776981 scopus 로고
    • Design of superstructures for osseointegrated fixtures
    • Klineberg IJ, Murray GM. Design of superstructures for osseointegrated fixtures. Swed Dent J Suppl 1985;28:63-69.
    • (1985) Swed Dent J Suppl , vol.28 , pp. 63-69
    • Klineberg, I.J.1    Murray, G.M.2
  • 47
    • 0030635617 scopus 로고    scopus 로고
    • Cement-retained versus screw-retained implant restorations: Achieving optimal occlusion and esthetics in implant dentistry
    • Hebel KS, Gajjar RC. Cement-retained versus screw-retained implant restorations: Achieving optimal occlusion and esthetics in implant dentistry. J Prosthet Dent 1997; 77(1):28-35.
    • (1997) J Prosthet Dent , vol.77 , Issue.1 , pp. 28-35
    • Hebel, K.S.1    Gajjar, R.C.2
  • 48
    • 0031262117 scopus 로고    scopus 로고
    • Comparison of strains produced in a bone simulant between conventional cast and resin-luted implant frameworks
    • Clelland NL, van Putten MC. Comparison of strains produced in a bone simulant between conventional cast and resin-luted implant frameworks. Int J Oral Maxillofac Implants 1997;12(6):793-799.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , Issue.6 , pp. 793-799
    • Clelland, N.L.1    Van Putten, M.C.2
  • 49
    • 0033158629 scopus 로고    scopus 로고
    • Alternative complete-arch cement-retained implant-supported fixed partial denture
    • Hofstede TM, Ercoli C, Hagan M. Alternative complete-arch cement-retained implant-supported fixed partial denture. J Prosthet Dent 1999;82(1):94-99.
    • (1999) J Prosthet Dent , vol.82 , Issue.1 , pp. 94-99
    • Hofstede, T.M.1    Ercoli, C.2    Hagan, M.3
  • 50
    • 0030238166 scopus 로고    scopus 로고
    • Cement-retained implant-supported fixed partial dentures: A 6-month to 3-year follow-up
    • Singer A, Serfaty V Cement-retained implant-supported fixed partial dentures: A 6-month to 3-year follow-up. Int J Oral Maxillofac Implants 1996;11(5):645-649.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , Issue.5 , pp. 645-649
    • Singer, A.1    Serfaty, V.2
  • 51
    • 0032086151 scopus 로고    scopus 로고
    • Retrievable cemented implant restorations
    • Chee WW, Torbati A, Albouy JP. Retrievable cemented implant restorations. J Prosthodont 1998;7(2):120-125.
    • (1998) J Prosthodont , vol.7 , Issue.2 , pp. 120-125
    • Chee, W.W.1    Torbati, A.2    Albouy, J.P.3
  • 52
    • 0026045373 scopus 로고
    • The Kulzer abutment luting; Kal technique. A direct assembly framework method for osseointegrated implant prostheses
    • Voitik AJ. The Kulzer abutment luting; Kal technique. A direct assembly framework method for osseointegrated implant prostheses. Implant Soc 1991;2(1):11-14.
    • (1991) Implant Soc , vol.2 , Issue.1 , pp. 11-14
    • Voitik, A.J.1
  • 53
    • 0028522448 scopus 로고
    • A new method to routinely achieve passive fit of ceramometal prostheses over Brånemark osseointegrated implants: A two-year report
    • Aparicio C. A new method to routinely achieve passive fit of ceramometal prostheses over Brånemark osseointegrated implants: A two-year report. Int J Periodontics Restorative Dent 1994;14(5):404-419.
    • (1994) Int J Periodontics Restorative Dent , vol.14 , Issue.5 , pp. 404-419
    • Aparicio, C.1
  • 55
    • 0031302220 scopus 로고    scopus 로고
    • Marginal fit consistency of copy-milled all-ceramic crowns during fabrication by light- And scanning-electron-microscopic analysis in vitro
    • Groton M, Girthofer S, Probster L. Marginal fit consistency of copy-milled all-ceramic crowns during fabrication by light-and scanning-electron-microscopic analysis in vitro. J Oral Rehabil 1997;24:871-881.
    • (1997) J Oral Rehabil , vol.24 , pp. 871-881
    • Groton, M.1    Girthofer, S.2    Probster, L.3
  • 56
    • 0033628733 scopus 로고    scopus 로고
    • Determination of the minimum number of marginal gap measurements required for practical in vitro testing
    • Groton M, Axmann D, Probster L, Weber H. Determination of the minimum number of marginal gap measurements required for practical in vitro testing. J Prosthet Dent 2000; 83(1):40-49.
    • (2000) J Prosthet Dent , vol.83 , Issue.1 , pp. 40-49
    • Groton, M.1    Axmann, D.2    Probster, L.3    Weber, H.4
  • 57
    • 0030178921 scopus 로고    scopus 로고
    • Tensile bond strength of resin luting cement to a porcelain-fusing noble alloy
    • Stokholm R, Isidor F, Ravnholt G. Tensile bond strength of resin luting cement to a porcelain-fusing noble alloy. Int J Prosthodont 1996;9(4):323-330.
    • (1996) Int J Prosthodont , vol.9 , Issue.4 , pp. 323-330
    • Stokholm, R.1    Isidor, F.2    Ravnholt, G.3
  • 58
    • 0031174191 scopus 로고    scopus 로고
    • The influence of cement thickness on the tensile strength of two resin cements
    • Chana HS, Ibbetson RJ, Pearson GJ, Eder A. The influence of cement thickness on the tensile strength of two resin cements. Int J Prosthodont 1997;10(4):340-344.
    • (1997) Int J Prosthodont , vol.10 , Issue.4 , pp. 340-344
    • Chana, H.S.1    Ibbetson, R.J.2    Pearson, G.J.3    Eder, A.4
  • 59
    • 0030325329 scopus 로고    scopus 로고
    • The bond strength of an adhesive resin luting cement to a variety of surface treatments of a high-palladium copper alloy
    • Lynde TA, Whitehill JM, Coffey JP, Meiers JC. The bond strength of an adhesive resin luting cement to a variety of surface treatments of a high-palladium copper alloy. J Prosthodont 1996;5(4):295-300.
    • (1996) J Prosthodont , vol.5 , Issue.4 , pp. 295-300
    • Lynde, T.A.1    Whitehill, J.M.2    Coffey, J.P.3    Meiers, J.C.4
  • 60
    • 0029396145 scopus 로고
    • Bond strength of an adhesive resin system with various dental substrates
    • Triolo PT, Kelsey WP, Barkmeier WW. Bond strength of an adhesive resin system with various dental substrates. J Prosthet Dent 1995;74(5):463-468.
    • (1995) J Prosthet Dent , vol.74 , Issue.5 , pp. 463-468
    • Triolo, P.T.1    Kelsey, W.P.2    Barkmeier, W.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.