메뉴 건너뛰기




Volumn 54, Issue 6, 2001, Pages 693-702

Macroscopic and Microscopic Study of the Right Coronary Artery after Radiofrequency Catheter Ablation of Cavotricuspid Isthmus in an Experimental Model;Estudio macro y microscópico de la arteria coronaria derecha tras ablación con catéter y radiofrecuencia del istmo cavotricuspídeo en un modelo experimental

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL; ARTICLE; CATHETER ABLATION; CATHETERIZATION; COMPARATIVE STUDY; CORONARY BLOOD VESSEL; HEART ATRIOVENTRICULAR NODE; HEART CATHETERIZATION; HEART VENTRICLE SEPTUM; PATHOLOGY; SWINE;

EID: 0035378516     PISSN: 03008932     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0300-8932(01)76384-1     Document Type: Article
Times cited : (12)

References (43)
  • 2
    • 9444295300 scopus 로고    scopus 로고
    • Role of the tricuspid annulus and the eustachian valve/ridge on atrial flutter. Relevance to catheter ablation of the septal isthmus and a new technique for rapid identification of ablation success
    • Nakagawa H, Lazzara R, Khastgir T, Beckman K, McClelland J, Imai S et al. Role of the tricuspid annulus and the eustachian valve/ridge on atrial flutter. Relevance to catheter ablation of the septal isthmus and a new technique for rapid identification of ablation success. Circulation 1996; 94: 407-424.
    • (1996) Circulation , vol.94 , pp. 407-424
    • Nakagawa, H.1    Lazzara, R.2    Khastgir, T.3    Beckman, K.4    McClelland, J.5    Imai, S.6
  • 4
    • 0032721106 scopus 로고    scopus 로고
    • Partial cavotricuspid isthmus block before ablation in patients with typical atrial flutter
    • Takahashi A, Shah D, Jaïs P, Hocini M, Clementy J, Haissaguerre M. Partial cavotricuspid isthmus block before ablation in patients with typical atrial flutter. J Am Coll Cardiol 1999; 33: 1996-2002.
    • (1999) J Am Coll Cardiol , vol.33 , pp. 1996-2002
    • Takahashi, A.1    Shah, D.2    Jaïs, P.3    Hocini, M.4    Clementy, J.5    Haissaguerre, M.6
  • 5
    • 24844439079 scopus 로고    scopus 로고
    • A prospective randomized comparison of irrigated catheter ablation versus conventional tip catheters for ablation of typical atrial flutter
    • Jais P, Shah D, Haissaguerre M, Takahashi A, Peng J, Hocine M et al. A prospective randomized comparison of irrigated catheter ablation versus conventional tip catheters for ablation of typical atrial flutter. Circulation 1999; 100: 3439.
    • (1999) Circulation , vol.100 , pp. 3439
    • Jais, P.1    Shah, D.2    Haissaguerre, M.3    Takahashi, A.4    Peng, J.5    Hocine, M.6
  • 6
    • 0029867927 scopus 로고    scopus 로고
    • Radiofrequency catheter ablation of common atrial flutter: Comparison of electrophysiologically guided focal ablation technique and linear ablation technique
    • Chen S, Chiang C, Wu T, Tai C, Lee S, Cheng C et al. Radiofrequency catheter ablation of common atrial flutter: comparison of electrophysiologically guided focal ablation technique and linear ablation technique. J Am Coll Cardiol 1996; 27: 860-868.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 860-868
    • Chen, S.1    Chiang, C.2    Wu, T.3    Tai, C.4    Lee, S.5    Cheng, C.6
  • 8
    • 0002902544 scopus 로고    scopus 로고
    • Difficulty in typical atrial flutter ablation depends on tricuspid-valve inferior vena cava isthmus anatomy
    • Yamauchi Y, Aonuma K, Oh J, Hachiya H, Kobayashi I, Kano H et al. Difficulty in typical atrial flutter ablation depends on tricuspid-valve inferior vena cava isthmus anatomy. Circulation 1999; 100: 3438.
    • (1999) Circulation , vol.100 , pp. 3438
    • Yamauchi, Y.1    Aonuma, K.2    Oh, J.3    Hachiya, H.4    Kobayashi, I.5    Kano, H.6
  • 9
    • 0031795163 scopus 로고    scopus 로고
    • The architecture of the atrial musculature between the orifice of the inferior caval vein and the tricuspid valve. The anatomy of the isthmus
    • Cabrera JA, Sánchez Quintana D, Ho S, Medina A, Anderson RH. The architecture of the atrial musculature between the orifice of the inferior caval vein and the tricuspid valve. The anatomy of the isthmus. J Cardiovasc Electrophysiol 1998; 9: 1186-1195.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 1186-1195
    • Cabrera, J.A.1    Sánchez Quintana, D.2    Ho, S.3    Medina, A.4    Anderson, R.H.5
  • 10
    • 0033564054 scopus 로고    scopus 로고
    • Angiographic anatomy of the inferior right atrial isthmus in patients with and without history of common atrial flutter
    • Cabrera JA, Sánchez Quintana D, Ho S, Medina A, Wanguemert F, Gross E et al. Angiographic anatomy of the inferior right atrial isthmus in patients with and without history of common atrial flutter. Circulation 1999; 99: 3017-3023.
    • (1999) Circulation , vol.99 , pp. 3017-3023
    • Cabrera, J.A.1    Sánchez Quintana, D.2    Ho, S.3    Medina, A.4    Wanguemert, F.5    Gross, E.6
  • 11
    • 0032931761 scopus 로고    scopus 로고
    • Human histopathologic findings following radiofrequency ablation of the tricuspid-inferior vena cava isthmus
    • Leonelli F, Natale A, O'Connor W. Human histopathologic findings following radiofrequency ablation of the tricuspid-inferior vena cava isthmus. J Cardiovasc Electrophysiol 1999; 10: 599-602.
    • (1999) J Cardiovasc Electrophysiol , vol.10 , pp. 599-602
    • Leonelli, F.1    Natale, A.2    O'Connor, W.3
  • 12
    • 0033972402 scopus 로고    scopus 로고
    • Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation
    • Petersen H, Chen X, Pietersen A, Svendsen J, Haunso S. Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation. PACE 2000; 23: 8-17.
    • (2000) PACE , vol.23 , pp. 8-17
    • Petersen, H.1    Chen, X.2    Pietersen, A.3    Svendsen, J.4    Haunso, S.5
  • 13
    • 7844250170 scopus 로고    scopus 로고
    • Cardiac troponin I and minor cardiac damage: Biochemical markers in a clinical model of myocardial lesions
    • Del Rey JM, Hernández Madrid A, Valiño JM, Rubí J, Mercader J, Moro C et al. Cardiac troponin I and minor cardiac damage: biochemical markers in a clinical model of myocardial lesions. Clin Chem 1998; 44: 2270-2276.
    • (1998) Clin Chem , vol.44 , pp. 2270-2276
    • Del Rey, J.M.1    Hernández Madrid, A.2    Valiño, J.M.3    Rubí, J.4    Mercader, J.5    Moro, C.6
  • 14
    • 0032462120 scopus 로고    scopus 로고
    • Biochemical markers and cardiac troponin I release after radiofrequency catheter ablation: Approach to size of necrosis
    • Madrid AH, del Rey JM, Rubí J, Ortega J, González-Rebollo JM, Seara JG et al. Biochemical markers and cardiac troponin I release after radiofrequency catheter ablation: approach to size of necrosis. Am Heart J 1998; 136: 948-955.
    • (1998) Am Heart J , vol.136 , pp. 948-955
    • Madrid, A.H.1    Del Rey, J.M.2    Rubí, J.3    Ortega, J.4    González-Rebollo, J.M.5    Seara, J.G.6
  • 15
    • 0032483049 scopus 로고    scopus 로고
    • Inverse relationship between electrode size and lesion size during radiofrequency ablation with active cooling
    • Nakagawa H, Wittkampf F, Yamanashi W, Pitha J, Imai S, Campbell B et al. Inverse relationship between electrode size and lesion size during radiofrequency ablation with active cooling. Circulation 1998; 98: 458-465.
    • (1998) Circulation , vol.98 , pp. 458-465
    • Nakagawa, H.1    Wittkampf, F.2    Yamanashi, W.3    Pitha, J.4    Imai, S.5    Campbell, B.6
  • 16
    • 0025095887 scopus 로고
    • Radiofrequency catheter ablation: The effect of electrode size on lesion volume in vivo
    • Langberg JJ, Lee MA, Chin MC, Rosenqvist M. Radiofrequency catheter ablation: the effect of electrode size on lesion volume in vivo. PACE 1990; 13: 1242-1248.
    • (1990) PACE , vol.13 , pp. 1242-1248
    • Langberg, J.J.1    Lee, M.A.2    Chin, M.C.3    Rosenqvist, M.4
  • 17
    • 0024433096 scopus 로고
    • Control of radiofrequency lesion size by power regulation
    • Wittkampf F, Hauer R, Robles de Medina E. Control of radiofrequency lesion size by power regulation. Circulation 1989; 80: 962-968.
    • (1989) Circulation , vol.80 , pp. 962-968
    • Wittkampf, F.1    Hauer, R.2    Robles De Medina, E.3
  • 18
    • 0033578467 scopus 로고    scopus 로고
    • Is 8-mm more effective than 4-mm tip electrode catheter for ablation of typical atrial flutter?
    • Tsai C, Tai C, Yu C, Chen Y, Hsieh M, Chiang C et al. Is 8-mm more effective than 4-mm tip electrode catheter for ablation of typical atrial flutter? Circulation 1999; 100: 768-771.
    • (1999) Circulation , vol.100 , pp. 768-771
    • Tsai, C.1    Tai, C.2    Yu, C.3    Chen, Y.4    Hsieh, M.5    Chiang, C.6
  • 19
    • 0029559129 scopus 로고
    • Radiofrequency delivery through a cooled catheter tip allows the creation of larger endomyocardial lesions in the ovine heart
    • Ruffy R, Imran MA, Santel DJ, Wharton JM. Radiofrequency delivery through a cooled catheter tip allows the creation of larger endomyocardial lesions in the ovine heart. J Cardiovasc Electrophysiol 1995: 6: 1089-1096.
    • (1995) J Cardiovasc Electrophysiol , vol.6 , pp. 1089-1096
    • Ruffy, R.1    Imran, M.A.2    Santel, D.J.3    Wharton, J.M.4
  • 20
    • 0003052784 scopus 로고    scopus 로고
    • Utility of tip thermometry during radiofrequency ablation in humans using an internally perfused saline cooled catheter
    • Wharton JM, Wilber D, Calkins H, Epstein A, Ellenbogen K, Carlson M et al. Utility of tip thermometry during radiofrequency ablation in humans using an internally perfused saline cooled catheter. Circulation 1997; 96: I-318.
    • (1997) Circulation , vol.96
    • Wharton, J.M.1    Wilber, D.2    Calkins, H.3    Epstein, A.4    Ellenbogen, K.5    Carlson, M.6
  • 21
    • 0031793610 scopus 로고    scopus 로고
    • Comparison of standard and irrigated radiofrequency ablation in the canine ventricle
    • Skrumeda L, Mehra R. Comparison of standard and irrigated radiofrequency ablation in the canine ventricle. J Cardiovasc Electrophysiol 1998; 9: 1196-1205.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 1196-1205
    • Skrumeda, L.1    Mehra, R.2
  • 22
    • 0031895674 scopus 로고    scopus 로고
    • Temperature-controlled irrigated tip radiofrequency catheter ablation: Comparison of in vivo and in vitro lesion dimensions for standard catheter and irrigated tip catheter with minimal infusion rate
    • Petersen HH, Chen X, Pietersen A, Svendsen JH, Haunso S. Temperature-controlled irrigated tip radiofrequency catheter ablation: comparison of in vivo and in vitro lesion dimensions for standard catheter and irrigated tip catheter with minimal infusion rate. J Cardiovasc Electrophysiol 1998; 9: 409-414.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 409-414
    • Petersen, H.H.1    Chen, X.2    Pietersen, A.3    Svendsen, J.H.4    Haunso, S.5
  • 23
    • 15444359497 scopus 로고    scopus 로고
    • Why a large tip electrode makes a deeper radiofrequency lesion: Effects of increase in electrode cooling and electrode-tissue interface area
    • Otomo K, Yamanashi WS, Tondo C, Antz M, Bussey J, Pitha JV et al. Why a large tip electrode makes a deeper radiofrequency lesion: effects of increase in electrode cooling and electrode-tissue interface area. J Cardiovasc Electrophysiol 1998; 9: 47-54.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 47-54
    • Otomo, K.1    Yamanashi, W.S.2    Tondo, C.3    Antz, M.4    Bussey, J.5    Pitha, J.V.6
  • 24
    • 0001136828 scopus 로고
    • Establishment of a dose-response relationship for high power chilled-tip radiofrequency current ablation in sheep
    • Wharton J, Nibley C, Sykes C, Rowan R, McLaughlin G, Chapman T et al. Establishment of a dose-response relationship for high power chilled-tip radiofrequency current ablation in sheep. J Am Coll Cardiol 1995; 293A: 777-783.
    • (1995) J Am Coll Cardiol , vol.293 A , pp. 777-783
    • Wharton, J.1    Nibley, C.2    Sykes, C.3    Rowan, R.4    McLaughlin, G.5    Chapman, T.6
  • 25
    • 0029559129 scopus 로고
    • Radiofrequency delivery through a cooled catheter tip allows the creation of larger endomyocardial lesions in the ovine heart
    • Ruffy R, Imran M, Santel D, Wharton M. Radiofrequency delivery through a cooled catheter tip allows the creation of larger endomyocardial lesions in the ovine heart. J Cardiovasc electrophysiol 1995; 6: 1089-1096.
    • (1995) J Cardiovasc Electrophysiol , vol.6 , pp. 1089-1096
    • Ruffy, R.1    Imran, M.2    Santel, D.3    Wharton, M.4
  • 26
    • 0028942447 scopus 로고
    • Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation
    • Nakagawa H, Yamanashi W, Pitha J, Arruda M, Wang X, Ohtonio K. Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation. Circulation 1995; 91: 2264-2273.
    • (1995) Circulation , vol.91 , pp. 2264-2273
    • Nakagawa, H.1    Yamanashi, W.2    Pitha, J.3    Arruda, M.4    Wang, X.5    Ohtonio, K.6
  • 27
    • 0002960259 scopus 로고    scopus 로고
    • The risk of the right coronary artery damage in catheter ablation of common type atrial flutter
    • Suga T, Igawa O, Adachi M, Yano A, Miake J, Inoue Y et al. The risk of the right coronary artery damage in catheter ablation of common type atrial flutter. Circulation 1999; 100: 2389.
    • (1999) Circulation , vol.100 , pp. 2389
    • Suga, T.1    Igawa, O.2    Adachi, M.3    Yano, A.4    Miake, J.5    Inoue, Y.6
  • 28
    • 0019997037 scopus 로고
    • Catheter-induced ablation of ihe atrioventricular junction to control refractory supraventricular arrhythmias
    • Scheinman MM, Morady F, Hess DS, Gonzales R. Catheter-induced ablation of ihe atrioventricular junction to control refractory supraventricular arrhythmias. JAMA 1982; 248: 851-855.
    • (1982) JAMA , vol.248 , pp. 851-855
    • Scheinman, M.M.1    Morady, F.2    Hess, D.S.3    Gonzales, R.4
  • 29
    • 0027534580 scopus 로고
    • Radiofrequency ablation of the inferior vena cava-tricuspid valve isthmus in common atrial flutter
    • Cosio FG, López-Gil M, Goicolea A, Arribas F, Barroso JL. Radiofrequency ablation of the inferior vena cava-tricuspid valve isthmus in common atrial flutter. Am J Cardiol 1993; 71: 705-709.
    • (1993) Am J Cardiol , vol.71 , pp. 705-709
    • Cosio, F.G.1    López-Gil, M.2    Goicolea, A.3    Arribas, F.4    Barroso, J.L.5
  • 30
    • 0039623232 scopus 로고    scopus 로고
    • La ablación con radiofrecuencia como primer tratamiento de elección en pacientes con aleteo auricular común. Argumentos en contra
    • García Cosío F, Pastor A, Núñez A. La ablación con radiofrecuencia como primer tratamiento de elección en pacientes con aleteo auricular común. Argumentos en contra. Rev Esp Cardiol 1999; 52: 233-236.
    • (1999) Rev Esp Cardiol , vol.52 , pp. 233-236
    • García Cosío, F.1    Pastor, A.2    Núñez, A.3
  • 31
    • 0033113028 scopus 로고    scopus 로고
    • La ablación con radiofrecuencia como primer tratamiento de elección en pacientes con aleteo auricular común. Argumentos a favor
    • Mont L. La ablación con radiofrecuencia como primer tratamiento de elección en pacientes con aleteo auricular común. Argumentos a favor. Rev Esp Cardiol 1999; 52: 227-232.
    • (1999) Rev Esp Cardiol , vol.52 , pp. 227-232
    • Mont, L.1
  • 32
    • 0032903237 scopus 로고    scopus 로고
    • Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium. Impact of ablation site, electrode size and convective cooling
    • Petersen H, Chen X, Pietersen A, Svendsen J, Haunso. Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium. Impact of ablation site, electrode size and convective cooling. Circulation 1999; 99: 319-325.
    • (1999) Circulation , vol.99 , pp. 319-325
    • Petersen, H.1    Chen, X.2    Pietersen, A.3    Svendsen, J.4    Haunso5
  • 33
    • 0033036508 scopus 로고    scopus 로고
    • Ablation of ventricular tachycardia with a saline-cooled radiofrequency catheter: Anatomic and histologic characteristics of the lesions in humans
    • Delacretaz E, Stevenson WG, Winters G, Mitchell R, Stewart S, Lynch K et al. Ablation of ventricular tachycardia with a saline-cooled radiofrequency catheter: anatomic and histologic characteristics of the lesions in humans. J Cardiovasc Electrophysiol 1999; 10: 860-865.
    • (1999) J Cardiovasc Electrophysiol , vol.10 , pp. 860-865
    • Delacretaz, E.1    Stevenson, W.G.2    Winters, G.3    Mitchell, R.4    Stewart, S.5    Lynch, K.6
  • 34
    • 0344447087 scopus 로고    scopus 로고
    • Successful irrigated-tip catheter ablation of atrial flutter resistant to conventional radiofrequency ablation
    • Jais P, Haissaguerre M, Shah DC, Takahashi A, Hocini M, Lavergne T et al. Successful irrigated-tip catheter ablation of atrial flutter resistant to conventional radiofrequency ablation. Circulation 1998; 98: 835-838.
    • (1998) Circulation , vol.98 , pp. 835-838
    • Jais, P.1    Haissaguerre, M.2    Shah, D.C.3    Takahashi, A.4    Hocini, M.5    Lavergne, T.6
  • 35
    • 0029101339 scopus 로고
    • Linear ablation of the isthmus between the inferior vena cava and tricuspid annulus for the treatment of atrial flutter. A study in the canine atrial flutter model
    • Tabuchi T, Okumura K, Matsunaga T, Tsunoda R, Jougasaki M, Yasue H et al. Linear ablation of the isthmus between the inferior vena cava and tricuspid annulus for the treatment of atrial flutter. A study in the canine atrial flutter model. Circulation 1995; 92: 1312-1319.
    • (1995) Circulation , vol.92 , pp. 1312-1319
    • Tabuchi, T.1    Okumura, K.2    Matsunaga, T.3    Tsunoda, R.4    Jougasaki, M.5    Yasue, H.6
  • 36
    • 0034700269 scopus 로고    scopus 로고
    • Efficacy and safety of an irrigated-tip catheter for the ablation of accessory pathways resistant to conventional radiofrequency ablation
    • Yamane T, Jaïs P, Shah D, Hocini M, Tian Peng J, Deisenhofer I et al. Efficacy and safety of an irrigated-tip catheter for the ablation of accessory pathways resistant to conventional radiofrequency ablation. Circulation 2000; 102: 2565-2568.
    • (2000) Circulation , vol.102 , pp. 2565-2568
    • Yamane, T.1    Jaïs, P.2    Shah, D.3    Hocini, M.4    Tian Peng, J.5    Deisenhofer, I.6
  • 37
    • 85046067848 scopus 로고
    • Complications of radiofrequency catheter ablation of arrhythmias
    • The Multicentre European Radiofrequency Survey (MEradiofrecuenciaS) Investigators of the Working Group on Arrhythmias of the European Society of Cardiology
    • Hindricks G. The Multicentre European Radiofequency Survey (MERFS). Complications of radiofrequency catheter ablation of arrhythmias. The Multicentre European Radiofrequency Survey (MEradiofrecuenciaS) Investigators of the Working Group on Arrhythmias of the European Society of Cardiology. Eur Heart J 1994; 15: 1290-1291.
    • (1994) Eur Heart J , vol.15 , pp. 1290-1291
    • Hindricks, G.1
  • 38
    • 0032935092 scopus 로고    scopus 로고
    • Catheter ablation of accessory pathways, atrioventricular nodal reentrant tachycardia, and the atrioventricular junction: Final results of a prospective, multicenter clinical trial
    • The Atakr Multicenter Investigators Group
    • Calkins H, Yong P, Miller J, Olshanky B, Carlson M, Saul P et al. Catheter ablation of accessory pathways, atrioventricular nodal reentrant tachycardia, and the atrioventricular junction: final results of a prospective, multicenter clinical trial. The Atakr Multicenter Investigators Group. Circulation 1999; 99: 262-270.
    • (1999) Circulation , vol.99 , pp. 262-270
    • Calkins, H.1    Yong, P.2    Miller, J.3    Olshanky, B.4    Carlson, M.5    Saul, P.6
  • 39
    • 0032926515 scopus 로고    scopus 로고
    • Catheter Ablation of Cardiac Arrhythmias. Usually cure, but complications may occur
    • Wellens HJJ. Catheter Ablation of Cardiac Arrhythmias. Usually cure, but complications may occur. Circulation 1999; 99: 195-197.
    • (1999) Circulation , vol.99 , pp. 195-197
    • Wellens, H.J.J.1
  • 40
    • 0034213761 scopus 로고    scopus 로고
    • Randomized comparison of two targets in typical atrial flutter ablation
    • Anselme F, Klug D, Scanu P, Poty H, Lacroix D, Kacet S et al. Randomized comparison of two targets in typical atrial flutter ablation. Am J Cardiol 2000; 85: 1302-1307.
    • (2000) Am J Cardiol , vol.85 , pp. 1302-1307
    • Anselme, F.1    Klug, D.2    Scanu, P.3    Poty, H.4    Lacroix, D.5    Kacet, S.6
  • 41
    • 0034612306 scopus 로고    scopus 로고
    • Tissue factor overexpression in rat arterial neointima models thrombosis and progression of advanced atherosclerosis
    • Hasenstab D, Lea H, Hart C, Lok S, Clowes A. Tissue factor overexpression in rat arterial neointima models thrombosis and progression of advanced atherosclerosis. Circulation 2000; 101: 2651-2657.
    • (2000) Circulation , vol.101 , pp. 2651-2657
    • Hasenstab, D.1    Lea, H.2    Hart, C.3    Lok, S.4    Clowes, A.5
  • 42
    • 0034028565 scopus 로고    scopus 로고
    • Distal end of the atrioventricular nodal artery predicts the risk of atrioventricular block during slow pathway catheter ablation of atrioventricular nodal re-entrant tachycardia
    • Lin JL, Huang SKS, Lai LP, Lin LJ, Chen H et al. Distal end of the atrioventricular nodal artery predicts the risk of atrioventricular block during slow pathway catheter ablation of atrioventricular nodal re-entrant tachycardia. Heart 2000; 83: 543-550.
    • (2000) Heart , vol.83 , pp. 543-550
    • Lin, J.L.1    Huang, S.K.S.2    Lai, L.P.3    Lin, L.J.4    Chen, H.5
  • 43
    • 0032954789 scopus 로고    scopus 로고
    • Right coronary artery occlusion as a complication of accessory pathway ablation in a 12-year-old treated with stenting
    • Khanal S, Ribeiro P, Platt M, Kuhn M. Right coronary artery occlusion as a complication of accessory pathway ablation in a 12-year-old treated with stenting. Cathet Cardiovasc Diagn 1999; 46: 59-61.
    • (1999) Cathet Cardiovasc Diagn , vol.46 , pp. 59-61
    • Khanal, S.1    Ribeiro, P.2    Platt, M.3    Kuhn, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.