Volumn 24, Issue 9, 2001, Pages 649-654
|
Tibial implants: Biomechanical and histomorphometric studies of hydroxyapatite-coated and uncoated stainless steel and titanium screws in long-term ovariectomized sheep
a a a a a |
Author keywords
Hydroxyapatite; Osteopenia; Sheep; Stainless steel; Titanium
|
Indexed keywords
BIOMECHANICS;
BONE;
COATED MATERIALS;
EXTRACTION;
SCREWS;
STAINLESS STEEL;
BIOMECHANICAL STUDIES;
CONTROL GROUPS;
CORTICAL BONE;
HISTOMORPHOMETRIC STUDY;
OSTEOINTEGRATION;
OSTEOPENIA;
SHEEP;
STAINLESS STEEL SCREWS;
TITANIA;
UNCOATED STAINLESS STEELS;
HYDROXYAPATITE;
HYDROXYAPATITE;
STAINLESS STEEL;
TITANIUM;
ANIMAL EXPERIMENT;
ANIMAL TISSUE;
ARTICLE;
BIOCOMPATIBILITY;
BIOMECHANICS;
BONE SCREW;
CONTROLLED STUDY;
CORTICAL BONE;
DIAPHYSIS;
EVALUATION;
EXPERIMENTAL SURGERY;
HISTOLOGY;
IMPLANT;
LONG TERM CARE;
MORPHOMETRICS;
NONHUMAN;
OVARIECTOMY;
PARAMETER;
SHEEP;
STATISTICAL ANALYSIS;
TIBIA;
TORQUE;
|
EID: 0035148947
PISSN: 03913988
EISSN: None
Source Type: Journal
DOI: 10.1177/039139880102400909 Document Type: Article |
Times cited : (30)
|