메뉴 건너뛰기




Volumn 52, Issue 1, 2000, Pages 119-126

Assessing the information content of phosphor produced medical images: Application to Zn2SiO4:Mn phosphor

Author keywords

Medical phosphors; MTF; Phosphor screens; Signal to noise ratio

Indexed keywords

IMAGE ANALYSIS; LIGHT MODULATION; MEDICAL IMAGING; OPTICAL TRANSFER FUNCTION; QUANTUM EFFICIENCY; SIGNAL TO NOISE RATIO; X RAYS; ZINC COMPOUNDS;

EID: 0033992132     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0969-8043(99)00116-5     Document Type: Article
Times cited : (11)

References (20)
  • 1
    • 0001939373 scopus 로고
    • The use of bar pattern test objects in assessing the resolution of film/screen systems
    • A.G. Haus. New York: American Association of Physicists in Medicine
    • Barnes G.T. The use of bar pattern test objects in assessing the resolution of film/screen systems. Haus A.G. The Physics of Medical Imaging Recording System Measurements and Techniques. 1979;138-151 American Association of Physicists in Medicine, New York.
    • (1979) The Physics of Medical Imaging Recording System Measurements and Techniques , pp. 138-151
    • Barnes, G.T.1
  • 2
    • 0023336825 scopus 로고
    • Analysis of detective quantum efficiency of a radiographic film-screen combination
    • Bunch P.C., Huff K.E., Van Metter R. Analysis of detective quantum efficiency of a radiographic film-screen combination. J. Opt. Soc. Am. A. 4:1987;902.
    • (1987) J. Opt. Soc. Am. a , vol.4 , pp. 902
    • Bunch, P.C.1    Huff, K.E.2    Van Metter, R.3
  • 6
    • 0002611183 scopus 로고
    • Detective quantum efficiency, signal to noise ratio, and the noise-equivalent number of quanta
    • New York: Academic Press
    • Dainty J.C., Shaw R. Detective quantum efficiency, signal to noise ratio, and the noise-equivalent number of quanta. Image science. 1974;152-188 Academic Press, New York.
    • (1974) Image Science , pp. 152-188
    • Dainty, J.C.1    Shaw, R.2
  • 7
    • 0004242397 scopus 로고
    • Fundamentals of radiation dosimetry
    • London: Institute of Physics
    • Greening J.R. Fundamentals of radiation dosimetry. Medical Physics Handbooks. 1985;Institute of Physics, London.
    • (1985) Medical Physics Handbooks
    • Greening, J.R.1
  • 8
    • 0023611229 scopus 로고
    • Imaging performance of a digital storage phosphor system
    • Hillen W., Schiebel U., Zaengel T. Imaging performance of a digital storage phosphor system. Med. Phys. 14:1987;744.
    • (1987) Med. Phys. , vol.14 , pp. 744
    • Hillen, W.1    Schiebel, U.2    Zaengel, T.3
  • 10
    • 0004266385 scopus 로고
    • Chicago: Year Book Medical Publishers
    • Hendee W.R. Medical Radiation Physics. 1970;145-148 Year Book Medical Publishers, Chicago.
    • (1970) Medical Radiation Physics , pp. 145-148
    • Hendee, W.R.1
  • 12
    • 0039860737 scopus 로고    scopus 로고
    • An experimental method for the determination of spatial frequency dependent detective quantum efficiency (DQE) of scintillators used in x-ray imaging detectors
    • Kandarakis I., Cavouras D., Panayiotakis G.S., Triantis D., Nomicos C.D. An experimental method for the determination of spatial frequency dependent detective quantum efficiency (DQE) of scintillators used in x-ray imaging detectors. Nucl. Instrum. and Meth. Phys. Res. 399:1997;335.
    • (1997) Nucl. Instrum. and Meth. Phys. Res. , vol.399 , pp. 335
    • Kandarakis, I.1    Cavouras, D.2    Panayiotakis, G.S.3    Triantis, D.4    Nomicos, C.D.5
  • 15
    • 0017841479 scopus 로고
    • Image information content and patient exposure
    • Motz J.W., Danos M. Image information content and patient exposure. Med. Phys. 5:1978;8.
    • (1978) Med. Phys. , vol.5 , pp. 8
    • Motz, J.W.1    Danos, M.2
  • 16
    • 0025156138 scopus 로고
    • Model of the spatial-frequency-dependent detective quantum efficiency of phosphor screens
    • Nishikawa R.M., Yaffe M.J. Model of the spatial-frequency-dependent detective quantum efficiency of phosphor screens. Med. Phys. 17:1990;894.
    • (1990) Med. Phys. , vol.17 , pp. 894
    • Nishikawa, R.M.1    Yaffe, M.J.2
  • 17
    • 0039247525 scopus 로고
    • Some modern aspects of image evaluation
    • A.G. Haus. New York: American Association of Physicists in Medicine
    • Shaw R. Some modern aspects of image evaluation. Haus A.G. The physics of medical imaging: Recording system, measurements and techniques. 1979;515-523 American Association of Physicists in Medicine, New York.
    • (1979) The Physics of Medical Imaging: Recording System, Measurements and Techniques , pp. 515-523
    • Shaw, R.1
  • 18
    • 0021621742 scopus 로고
    • An analysis of the fundamental limitations of screen-film systems for x-ray detection
    • Shaw R., Van Metter R. An analysis of the fundamental limitations of screen-film systems for x-ray detection. Proc. SPIE. 454:1984;128.
    • (1984) Proc. SPIE , vol.454 , pp. 128
    • Shaw, R.1    Van Metter, R.2
  • 20
    • 0026585446 scopus 로고
    • Describing the signal-transfer characteristics of asymmetrical radiographic screen-film systems
    • Van Metter R. Describing the signal-transfer characteristics of asymmetrical radiographic screen-film systems. Med. Phys. 19:1992;53.
    • (1992) Med. Phys. , vol.19 , pp. 53
    • Van Metter, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.