메뉴 건너뛰기




Volumn 60, Issue 2, 2001, Pages 203-213

Application of a test package in an intercomparison of the photon dose calculation performance of treatment planning systems used in a clinical setting

Author keywords

Dose calculation; Quality assurance; Treatment planning system

Indexed keywords

ARTICLE; COLLIMATOR; COMPARATIVE STUDY; DOSE CALCULATION; DOSIMETRY; GEOMETRY; INTERMETHOD COMPARISON; LINEAR ACCELERATOR; PHOTON; PREDICTION; PRIORITY JOURNAL; QUALITY CONTROL; RADIATION BEAM; RADIATION DEPTH DOSE; RADIATION DOSE; RADIATION FIELD; TREATMENT PLANNING;

EID: 0034963623     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-8140(01)00304-8     Document Type: Article
Times cited : (59)

References (32)
  • 1
    • 0031469933 scopus 로고    scopus 로고
    • Application of AAPM Radiation Therapy Committee Task Group 23 test package for comparison of two treatment planning systems for photon external beam radiotherapy
    • (1997) Med Phys , vol.24 , pp. 2043-2054
    • Alam, R.1    Ibbott, G.S.2    Pourang, R.3    Nath, R.4
  • 3
    • 0000974827 scopus 로고    scopus 로고
    • AAPM Report No. 53. Quality assurance for clinical radiotherapy treatment planning Report of Task Group 53 of the Radiation Therapy Committee
    • (1998) Med Phys , vol.25 , pp. 1773-1829
  • 5
    • 0034036575 scopus 로고    scopus 로고
    • A method to check the accuracy of dose computation using quality index: Application to scatter contribution in high energy photon beams
    • (2000) Med Phys , vol.27 , pp. 1018-1024
    • Caneva, S.1    Rosenwald, J.C.2    Zefkili, S.3
  • 8
    • 0018193038 scopus 로고
    • Implementation of the Philips treatment planning system for use in radiation teletherapy
    • (1978) Br J Radiol , vol.51 , pp. 613-621
    • Dale, R.G.1
  • 12
    • 0027237136 scopus 로고
    • External beam treatment planning, can we deliver what we plan?
    • (1993) Acta Oncol , vol.32 , pp. 445-451
    • Harrison, R.M.1
  • 21
    • 0003050844 scopus 로고
    • Quality assurance in treatment planning. Report from the German task group Proc. IXth ICCR
    • Bruinvis IAD, van der Giessen PH, van Kleffens HJ, Whitkamper FW, editors. The use of computers in radiation therapy. Amsterdam, Elsevier
    • (1987) , pp. 45-48
    • Rosenow, U.F.1    Dannhausen, H.-W.2    Lubbert, K.3
  • 23
    • 0004666807 scopus 로고
    • Accuracy of dose calculations of the Philips treatment planning system OSS for blocked fields. Quality assurance in treatment planning. Report from the German task group Proc. Xth ICCR
    • Bruinvis IAD, van der Giessen PH, van Kleffens HJ, Whitkamper FW, editors. The use of computers in radiation therapy. Amsterdam, Elsevier
    • (1987) , pp. 57-60
    • Sauer, O.1    Nowak, G.2    Richter, J.3
  • 26
    • 0004691110 scopus 로고
    • A three-dimensional photon beam model used in a microcomputer planning system Proc. IXth ICCR
    • Bruinvis IAD, van der Giessen PH, van Kleffens HJ, Whitkamper FW, editors. The use of computers in radiation therapy. Amsterdam, Elsevier
    • (1987) , pp. 517-519
    • Van der Linden, P.M.1