메뉴 건너뛰기




Volumn 27, Issue 5, 2000, Pages 1018-1024

A method to check the accuracy of dose computation using quality index: Application to scatter contribution in high energy photon beams

Author keywords

Accuracy quantitative evaluation treatment planning systems

Indexed keywords

PARTICLE BEAMS; PHANTOMS; PHOTONS; QUALITY ASSURANCE; STATISTICAL TESTS;

EID: 0034036575     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598967     Document Type: Article
Times cited : (10)

References (22)
  • 2
    • 33744575150 scopus 로고
    • Quality control of 3D treatment planning systems used for conformal radiotherapy
    • DGMP
    • J. C. Rosenwald, "Quality control of 3D treatment planning systems used for conformal radiotherapy," Medizinische Physik 95 Würzburg, DGMP, pp. 168-169 (1995).
    • (1995) Medizinische Physik 95 Würzburg , pp. 168-169
    • Rosenwald, J.C.1
  • 3
    • 0031789601 scopus 로고    scopus 로고
    • Quality assurance for clinical radiotherapy treatment planning: Report of AAPM Radiation Therapy Committee Task Group 53
    • B. Fraass, K. Doppke, M. Hunt, G. Kutcher, G. Starkschall, R. Stern, and J. Van Dyke, "Quality assurance for clinical radiotherapy treatment planning: Report of AAPM Radiation Therapy Committee Task Group 53," Med. Phys. 25, 1773-1829 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1773-1829
    • Fraass, B.1    Doppke, K.2    Hunt, M.3    Kutcher, G.4    Starkschall, G.5    Stern, R.6    Van Dyke, J.7
  • 5
    • 0028230872 scopus 로고
    • Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Commitee Task Group 40
    • G. Kutcher et al., "Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Commitee Task Group 40," Med. Phys. 21, 581-618 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 581-618
    • Kutcher, G.1
  • 9
    • 0019148745 scopus 로고
    • Performance evaluation of computerized treatment planning systems for radiotherapy: External photon beams
    • E. C. McCullough, and A. M. Krueger, "Performance evaluation of computerized treatment planning systems for radiotherapy: External photon beams," Int. J. Radiat. Oncol., Biol., Phys. 6, 1599-1605 (1980).
    • (1980) Int. J. Radiat. Oncol., Biol., Phys. , vol.6 , pp. 1599-1605
    • McCullough, E.C.1    Krueger, A.M.2
  • 11
    • 0021045338 scopus 로고
    • Determination of the accuracy of different computer planning systems for treatment with external photon beams
    • C. Westermann, B. Mijnheer, and H. van Kleffens, "Determination of the accuracy of different computer planning systems for treatment with external photon beams," Radiother. Oncol. 1, 339-347 (1984).
    • (1984) Radiother. Oncol. , vol.1 , pp. 339-347
    • Westermann, C.1    Mijnheer, B.2    Van Kleffens, H.3
  • 16
    • 0031447649 scopus 로고    scopus 로고
    • Intercomparison of treatment planning systems (TPS) used in radiotherapy: Progress report of the TPS group of the European Dynarad project
    • E. Panitsa et al., "Intercomparison of treatment planning systems (TPS) used in radiotherapy: Progress report of the TPS group of the European Dynarad project," Phys. Medica 13, 139-143 (1997).
    • (1997) Phys. Medica , vol.13 , pp. 139-143
    • Panitsa, E.1
  • 17
    • 0031603753 scopus 로고    scopus 로고
    • Tests d'évaluation des systèmes informatiques concernant le calcul de la dose en trois dimensions
    • M. Simonian-Sauve and C. Smart, "Tests d'évaluation des systèmes informatiques concernant le calcul de la dose en trois dimensions," Cancer Radiother. 2, 53-62 (1998).
    • (1998) Cancer Radiother. , vol.2 , pp. 53-62
    • Simonian-Sauve, M.1    Smart, C.2
  • 18
    • 0028902539 scopus 로고
    • Depth dose under narrow shielding blocks: A comparison of measured and calculated dose
    • J. B. Davis, and B. Reiner, "Depth dose under narrow shielding blocks: a comparison of measured and calculated dose," Radiother. Oncol. 34, 219-227 (1995).
    • (1995) Radiother. Oncol. , vol.34 , pp. 219-227
    • Davis, J.B.1    Reiner, B.2
  • 19
    • 0029004883 scopus 로고
    • Quality control of inhomogeneity correction algorithms used in treatment planning systems
    • C. Kappas and J. C. Rosenwald, "Quality control of inhomogeneity correction algorithms used in treatment planning systems," Int. J. Radiat. Oncol., Biol., Phys. 32, 847-858 (1995).
    • (1995) Int. J. Radiat. Oncol., Biol., Phys. , vol.32 , pp. 847-858
    • Kappas, C.1    Rosenwald, J.C.2
  • 20
    • 0023196050 scopus 로고
    • Dose buildup for obliquely incident photon beams
    • B. J. Gerbi, A. Soleimani-Meigooni, and F. M. Khan, "Dose buildup for obliquely incident photon beams," Med. Phys. 14, 393-399 (1987).
    • (1987) Med. Phys. , vol.14 , pp. 393-399
    • Gerbi, B.J.1    Soleimani-Meigooni, A.2    Khan, F.M.3
  • 21
    • 85027233623 scopus 로고    scopus 로고
    • QA for 3D treatment planning systems
    • Edinburgh, Scotland, UK, Radiother. Oncol. Abstract no709
    • J. C. Rosenwald, "QA for 3D treatment planning systems," 17th Annual ESTRO Meeting, Edinburgh, Scotland, UK, Radiother. Oncol. 48, S180 Abstract no709 (1998).
    • (1998) 17th Annual ESTRO Meeting , vol.48
    • Rosenwald, J.C.1
  • 22
    • 0012228915 scopus 로고    scopus 로고
    • Quantitative assessement of build-up effect beyond air-tissue interface for quality control of treatment planning systems
    • Göttingen, Germany, Radiother. Oncol. Abstract no49
    • S. Caneva, J. C. Rosenwald, and S. Zefkili, "Quantitative assessement of build-up effect beyond air-tissue interface for quality control of treatment planning systems," 5th Biennial ESTRO Meeting on Physics for Clinical Radiotherapy, Göttingen, Germany, Radiother. Oncol. 51, S13 Abstract no49 (1999).
    • (1999) 5th Biennial ESTRO Meeting on Physics for Clinical Radiotherapy , vol.51
    • Caneva, S.1    Rosenwald, J.C.2    Zefkili, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.