메뉴 건너뛰기




Volumn 132, Issue 4, 2001, Pages 501-506

Relationship between visual field testing and scanning laser polarimetry in patients with a large cup-to-disk ratio

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIAGNOSTIC VALUE; DISCRIMINANT ANALYSIS; EARLY DIAGNOSIS; GLAUCOMA; HUMAN; MAJOR CLINICAL STUDY; NERVE FIBER; OPTIC NERVE; POLARIMETRY; PRIORITY JOURNAL; SCANNING LASER OPHTHALMOSCOPY; VISUAL FIELD;

EID: 0034800982     PISSN: 00029394     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-9394(01)01107-2     Document Type: Article
Times cited : (3)

References (20)
  • 1
    • 0024416486 scopus 로고
    • Glaucomalike discs without increased intraocular pressure or visual field loss
    • Tomita G, Takamoto T, Schwartz B. Glaucomalike discs without increased intraocular pressure or visual field loss. Am J Ophthalmol 1989;108:496-504.
    • (1989) Am J Ophthalmol , vol.108 , pp. 496-504
    • Tomita, G.1    Takamoto, T.2    Schwartz, B.3
  • 2
    • 0027433672 scopus 로고
    • Differences of retinal nerve fiber layer thickness between normal and glaucoma-like discs (physiologic cups) matched by optic disc area
    • Peigne G, Schwartz B, Takamoto T. Differences of retinal nerve fiber layer thickness between normal and glaucoma-like discs (physiologic cups) matched by optic disc area. Acta Ophthalmol (Copenh) 1993;71:451-457.
    • (1993) Acta Ophthalmol (Copenh) , vol.71 , pp. 451-457
    • Peigne, G.1    Schwartz, B.2    Takamoto, T.3
  • 3
    • 0026642603 scopus 로고
    • An evaluation of optic disc and nerve fiber layer examinations in monitoring progress of early glaucomatous damage
    • Quigley HA, Katz J, Derick RJ, Gilbert D, Sommer A. An evaluation of optic disc and nerve fiber layer examinations in monitoring progress of early glaucomatous damage. Ophthalmology 1992;99:19-28.
    • (1992) Ophthalmology , vol.99 , pp. 19-28
    • Quigley, H.A.1    Katz, J.2    Derick, R.J.3    Gilbert, D.4    Sommer, A.5
  • 4
    • 0031890436 scopus 로고    scopus 로고
    • Peripapillary nerve fiber layer thickness measurement reproducibility using scanning laser polarimetry
    • Hoh ST, Ishikawa H, Greenfield DS, Liebmann JM, Chew SJ, Ritch R. Peripapillary nerve fiber layer thickness measurement reproducibility using scanning laser polarimetry. J Glaucoma 1998;7:12-15.
    • (1998) J Glaucoma , vol.7 , pp. 12-15
    • Hoh, S.T.1    Ishikawa, H.2    Greenfield, D.S.3    Liebmann, J.M.4    Chew, S.J.5    Ritch, R.6
  • 5
    • 0031459317 scopus 로고    scopus 로고
    • Reproducibility of retardation measurements with the Nerve Fiber Analyzer II
    • Zangwill L, Berry CA, Garden VS, Weinreb RN. Reproducibility of retardation measurements with the Nerve Fiber Analyzer II. J Glaucoma 1997;6:384-389.
    • (1997) J Glaucoma , vol.6 , pp. 384-389
    • Zangwill, L.1    Berry, C.A.2    Garden, V.S.3    Weinreb, R.N.4
  • 6
    • 0032470784 scopus 로고    scopus 로고
    • Differentiating patients with glaucoma from glaucoma suspects and normal subjects by nerve fiber layer assessment with scanning laser polarimetry
    • Choplin NT, Lundy DC, Dreher AW. Differentiating patients with glaucoma from glaucoma suspects and normal subjects by nerve fiber layer assessment with scanning laser polarimetry. Ophthalmology 1998;105:2068-2077.
    • (1998) Ophthalmology , vol.105 , pp. 2068-2077
    • Choplin, N.T.1    Lundy, D.C.2    Dreher, A.W.3
  • 7
    • 0029044003 scopus 로고
    • Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eye
    • Weinreb RN, Shakiba S, Zangwill L. Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eye. Am J Ophthalmol 1995;119:627-636.
    • (1995) Am J Ophthalmol , vol.119 , pp. 627-636
    • Weinreb, R.N.1    Shakiba, S.2    Zangwill, L.3
  • 8
    • 0028864556 scopus 로고
    • Association between quantitative nerve fiber layer measurement and visual field loss in glaucoma
    • Weinreb RN, Shakiba S, Sample PA, et al. Association between quantitative nerve fiber layer measurement and visual field loss in glaucoma. Am J Ophthalmol 1995;120:732-738.
    • (1995) Am J Ophthalmol , vol.120 , pp. 732-738
    • Weinreb, R.N.1    Shakiba, S.2    Sample, P.A.3
  • 9
    • 0031049984 scopus 로고    scopus 로고
    • The sensitivity and specificity of nerve fiber layer measurements in glaucoma as determined with scanning laser polarimetry
    • Tjon-Fo-Sang MT, Lemij HG. The sensitivity and specificity of nerve fiber layer measurements in glaucoma as determined with scanning laser polarimetry. Am J Ophthalmol 1997;123:62-69.
    • (1997) Am J Ophthalmol , vol.123 , pp. 62-69
    • Tjon-Fo-Sang, M.T.1    Lemij, H.G.2
  • 12
    • 0030754476 scopus 로고    scopus 로고
    • Relationship between cup-disc ratio and optic disc diameter: The blue mountains eye study
    • Healey PR, Mitchell P, Smith W, Wang JJ. Relationship between cup-disc ratio and optic disc diameter: the Blue Mountains Eye Study. Aust N Z J Ophthalmol 1997;25(suppl 1):S99-S101.
    • (1997) Aust N Z J Ophthalmol , vol.25 , Issue.1 SUPPL.
    • Healey, P.R.1    Mitchell, P.2    Smith, W.3    Wang, J.J.4
  • 13
    • 0027474018 scopus 로고
    • Optic disc diameter influences the ability to detect glaucomatous disc damage
    • Heijl A, Molder H. Optic disc diameter influences the ability to detect glaucomatous disc damage. Acta Ophthalmol (Copenh) 1993;71:122-129.
    • (1993) Acta Ophthalmol (Copenh) , vol.71 , pp. 122-129
    • Heijl, A.1    Molder, H.2
  • 14
    • 0027198822 scopus 로고
    • Effect of repetitive imaging on topographic measurements of the optic nerve head
    • Weinreb RN, Lusky M, Bartsch DU, Morsman D. Effect of repetitive imaging on topographic measurements of the optic nerve head. Arch Ophthalmol 1993;111:636-638.
    • (1993) Arch Ophthalmol , vol.111 , pp. 636-638
    • Weinreb, R.N.1    Lusky, M.2    Bartsch, D.U.3    Morsman, D.4
  • 15
    • 0029738124 scopus 로고    scopus 로고
    • Optic nerve head topography in ocular hypertertensive eyes using confocal scanning laser ophthalmoscopy
    • Zangwill L, van Horn S, de Souza Lima M, Sample PA, Weinreb RN. Optic nerve head topography in ocular hypertertensive eyes using confocal scanning laser ophthalmoscopy. Am J Ophthalmol 1996;122:520-525.
    • (1996) Am J Ophthalmol , vol.122 , pp. 520-525
    • Zangwill, L.1    Van Horn, S.2    De Souza Lima, M.3    Sample, P.A.4    Weinreb, R.N.5
  • 16
    • 0003351355 scopus 로고
    • Similarities of total disc parameters for glaucoma-like and open angle glaucoma discs matched by optic disc area size
    • Krigelstein GK, ed. Berlin: Springer-Verlag
    • Peigne G, Schwartz B, Takamoto T. Similarities of total disc parameters for glaucoma-like and open angle glaucoma discs matched by optic disc area size. In: Krigelstein GK, ed. Glaucoma update IV. Berlin: Springer-Verlag, 1991:86-94.
    • (1991) Glaucoma Update IV , pp. 86-94
    • Peigne, G.1    Schwartz, B.2    Takamoto, T.3
  • 18
    • 0027209047 scopus 로고
    • Blue-on-yellow perimetry can predict the development of glaucomatous visual fields loss
    • Johnson CA, Brandt JD, Khong AM. Blue-on-yellow perimetry can predict the development of glaucomatous visual fields loss. Arch Ophthalmol 1993;11:645-650.
    • (1993) Arch Ophthalmol , vol.11 , pp. 645-650
    • Johnson, C.A.1    Brandt, J.D.2    Khong, A.M.3
  • 19
    • 0032698995 scopus 로고    scopus 로고
    • Achromatic and short wavelength automated perimetry in patients with glaucomatous large cups
    • Mansberger SL, Sample PA, Zangwill L, Weinreb RN. Achromatic and short wavelength automated perimetry in patients with glaucomatous large cups. Arch Ophthalmol 1999;117:1473-1477.
    • (1999) Arch Ophthalmol , vol.117 , pp. 1473-1477
    • Mansberger, S.L.1    Sample, P.A.2    Zangwill, L.3    Weinreb, R.N.4
  • 20
    • 0028877746 scopus 로고
    • Short-wave length automated perimetry in low-, medium-, and high-risk ocular hypertensive eyes
    • Johnson CA, Brandt JD, Khong AM. Short-wave length automated perimetry in low-, medium-, and high-risk ocular hypertensive eyes. Arch Ophthalmol 1995;113:70-76.
    • (1995) Arch Ophthalmol , vol.113 , pp. 70-76
    • Johnson, C.A.1    Brandt, J.D.2    Khong, A.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.