Volumn 6, Issue 16, 2001, Pages 76-105

Ventilators for noninvasive positive pressure ventilation: Technical aspects

Author keywords

Bilevel ventilators; Mechanical ventilators; Noninvasive ventilation; Portable ventilators; Respiratory failure; Ventilators.

Indexed keywords

OXYGEN;

EID: 0034769545     PISSN: 1025448X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (17)

References (47)
  • 2
    • 0023018767 scopus 로고
    • Clinical applications of body ventilators
    • (1986) Chest , vol.90 , pp. 897-905
    • Hill, N.S.1
  • 5
    • 0032766123 scopus 로고    scopus 로고
    • NIPPV: Patient-ventilator synchrony, the difference between success and failure?
    • (1999) Intens Care Med , vol.25 , pp. 645-647
    • Kacmarek, R.M.1
  • 9
    • 0027455012 scopus 로고
    • Intermittent positive pressure ventilation via the mouth as an alternative to tracheostomy for 257 ventilator users
    • (1993) Chest , vol.103 , pp. 174-182
    • Bach, J.R.1    Alba, A.S.2    Saporito, L.R.3
  • 17
    • 0025182269 scopus 로고
    • Obstructive sleep apnea treated by independently adjusted inspiratory and expiratory positive airway pressure via nasal mask
    • (1990) Chest , vol.98 , pp. 317-324
    • Sanders, M.H.1    Kern, N.B.2
  • 24
    • 0031791689 scopus 로고    scopus 로고
    • Respiratory muscle performance, pulmonary mechanics, and gas exchange between the BiPAP S/T-D system and Servo Ventilator 900C with bilevel positive airway pressure ventilation following gradual pressure support weaning
    • (1998) Chest , vol.114 , pp. 1390-1396
    • Patel, R.G.1    Petrini, M.F.2
  • 29
    • 0029829601 scopus 로고    scopus 로고
    • Increased initial flow rate reduces inspiratory work of breathing during pressure support ventilation in patients with exacerbation of chronic obstructive pulmonary disease
    • (1996) Intens Care Med , vol.22 , pp. 1147-1154
    • Bonmarchand, G.1    Chevron, V.2    Chopin, C.3
  • 30
    • 0028943947 scopus 로고
    • Nocturnal assisted ventilation using bilevel positive airway pressure: The effect of expiratory positive airway pressure
    • (1995) Eur Respir J , vol.8 , pp. 436-440
    • Elliott, M.W.1    Simonds, A.K.2
  • 41
    • 0025957086 scopus 로고
    • Effects of initial flow rate and breath termination criteria on pressure support ventilation
    • (1991) Chest , vol.99 , pp. 134-138
    • MacIntyre, N.R.1    Ho, L.-I.2
  • 43
    • 0032469970 scopus 로고    scopus 로고
    • Effects of different pressure support termination criteria on patient-ventilator synchrony
    • (1998) Respir Care , vol.43 , pp. 1048-1057
    • Yamada, Y.1    Du, H.-L.2
  • 46
    • 0032514508 scopus 로고    scopus 로고
    • A comparison of noninvasive positive-pressure ventilation and conventional mechanical ventilation in patients with acute respiratory failure
    • (1998) N Engl J Med , vol.339 , pp. 429-435
    • Antonelli, M.1    Conti, G.2    Rocco, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.