메뉴 건너뛰기




Volumn 3, Issue , 2000, Pages 2118-2121

Respiratory gating of sliding window IMRT

Author keywords

[No Author keywords available]

Indexed keywords

CAMERAS; COMPUTER CONTROL; DENSITY (OPTICAL); DOSIMETRY; INFRARED RADIATION; OPTICAL COLLIMATORS; POLYSTYRENES; RESPIRATORY MECHANICS; RESPIRATORY SYSTEM;

EID: 0034444887     PISSN: 05891019     EISSN: None     Source Type: Journal    
DOI: 10.1109/IEMBS.2000.900547     Document Type: Article
Times cited : (4)

References (8)
  • 1
    • 0028034318 scopus 로고
    • The potential and limitations of the inverse radiotherapy technique
    • R. Mohan X. Wang A. Jackson The potential and limitations of the inverse radiotherapy technique Radiother. Oncol. 32 232 248 1994
    • (1994) Radiother. Oncol. , vol.32 , pp. 232-248
    • Mohan, R.1    Wang, X.2    Jackson, A.3
  • 2
    • 0029865277 scopus 로고    scopus 로고
    • Dosimetric verification of intensity-modulated fields
    • S. Wang S. Splrou T. LoSasso Dosimetric verification of intensity-modulated fields Med. Phys. 23 317 327 1996
    • (1996) Med. Phys. , vol.23 , pp. 317-327
    • Wang, S.1    Splrou, S.2    LoSasso, T.3
  • 3
    • 0030199938 scopus 로고    scopus 로고
    • Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with multileaf collimation
    • C. C. Ling C. Barman C. Chui Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with multileaf collimation Int. J. Radiat. Oncol. Biol. Phys. 35 721 730 1996
    • (1996) Int. J. Radiat. Oncol. Biol. Phys. , vol.35 , pp. 721-730
    • Ling, C.C.1    Barman, C.2    Chui, C.3
  • 4
    • 0032810589 scopus 로고    scopus 로고
    • Intensity-modulated tangential beam irradiation of the intact breast
    • L. Hong M. Hunt C. Chui Intensity-modulated tangential beam irradiation of the intact breast Int. J. Radiat. Oncol. Biol. Phys 44 1155 1164 1999
    • (1999) Int. J. Radiat. Oncol. Biol. Phys , vol.44 , pp. 1155-1164
    • Hong, L.1    Hunt, M.2    Chui, C.3
  • 5
    • 0032844267 scopus 로고    scopus 로고
    • Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation
    • J. Hanley M.M. Debois D. Mah Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation Int. Jnl. Radiat. Oncol. Biol. Phys 45 1999
    • (1999) Int. Jnl. Radiat. Oncol. Biol. Phys , vol.45
    • Hanley, J.1    Debois, M.M.2    Mah, D.3
  • 6
    • 0004259036 scopus 로고    scopus 로고
    • Teletherapy: Present and Future
    • Treatment Setup Verification Advanced Medical Publishing WI, Madison
    • J. Balter R. K. Ten Haken Κ. L. Lam Teletherapy: Present and Future 1996 Advanced Medical Publishing WI, Madison Treatment Setup Verification
    • (1996)
    • Balter, J.1    Ten Haken, R.K.2    Lam, Κ.L.3
  • 7
    • 0030047783 scopus 로고    scopus 로고
    • Respiration gated radiotherapy treatment: a technical study
    • H.D. Kubo B.C. Hill Respiration gated radiotherapy treatment: a technical study Phys. Med. Biol. 41 83 91 1996
    • (1996) Phys. Med. Biol. , vol.41 , pp. 83-91
    • Kubo, H.D.1    Hill, B.C.2
  • 8
    • 0032704370 scopus 로고    scopus 로고
    • A comparison of beam characteristics for gated and ncngated clinical x-ray beams
    • C.R. Ramsey I. L. Cordrey A. L. Oliver A comparison of beam characteristics for gated and ncngated clinical x-ray beams Med. Phys. 26 21086 22091 1999
    • (1999) Med. Phys. , vol.26 , pp. 21086-22091
    • Ramsey, C.R.1    Cordrey, I.L.2    Oliver, A.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.