메뉴 건너뛰기




Volumn 13, Issue 4, 2000, Pages 178-190

Wavelet compression on detection of brain lesions with magnetic resonance imaging

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; BRAIN; COMPUTER WORKSTATIONS; DIGITAL IMAGE STORAGE; IMAGE COMPRESSION; IMAGE QUALITY; INFORMATION RETRIEVAL SYSTEMS; RADIOLOGY; STATISTICAL METHODS;

EID: 0034310649     PISSN: 08971889     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03168393     Document Type: Article
Times cited : (20)

References (22)
  • 1
    • 0029248912 scopus 로고
    • Radiologie image compression: A review
    • Wong S, Zaremba L, Gooden D, et al: Radiologie image compression: A review. Proc IEEE 83:194-218, 1995
    • (1995) Proc IEEE , vol.83 , pp. 194-218
    • Wong, S.1    Zaremba, L.2    Gooden, D.3
  • 2
    • 0027688479 scopus 로고
    • Displaying radiologic images on personal computers: Image storage and compression: Part 1
    • Gillespy T 3rd, Rowberg AH: Displaying radiologic images on personal computers: Image storage and compression: Part 1. J Digit Imaging 6:197-204, 1993
    • (1993) J Digit Imaging , vol.6 , pp. 197-204
    • Gillespy III, T.1    Rowberg, A.H.2
  • 3
    • 0026142897 scopus 로고
    • The JPEG still picture compression standard
    • Wallace GK: The JPEG still picture compression standard. Commun Assoc Comput Machinery 34:31-44, 1991
    • (1991) Commun Assoc Comput Machinery , vol.34 , pp. 31-44
    • Wallace, G.K.1
  • 4
    • 0031882994 scopus 로고    scopus 로고
    • Wavelet compression of medical images
    • Erickson BJ, Manduca A, Palisson P, et al: Wavelet compression of medical images. Radiology 206:599-607, 1998
    • (1998) Radiology , vol.206 , pp. 599-607
    • Erickson, B.J.1    Manduca, A.2    Palisson, P.3
  • 5
    • 0027740437 scopus 로고
    • Interactive wavelet-based 2-D and 3-D image compression
    • Manduca A: Interactive wavelet-based 2-D and 3-D image compression. Proc SPIE 1897:307-318, 1993
    • (1993) Proc SPIE , vol.1897 , pp. 307-318
    • Manduca, A.1
  • 6
    • 0032471099 scopus 로고    scopus 로고
    • Wavelet versus JPEG (Joint Photographic Expert Group) and fractal compression: Impact on the detection of low-contrast details in computed radiographs
    • Ricke J, Maass P, Lopez Hanninen E, et al: Wavelet versus JPEG (Joint Photographic Expert Group) and fractal compression: Impact on the detection of low-contrast details in computed radiographs. Invest Radiol 33:456-463, 1998
    • (1998) Invest Radiol , vol.33 , pp. 456-463
    • Ricke, J.1    Maass, P.2    Lopez Hanninen, E.3
  • 7
    • 0032588401 scopus 로고    scopus 로고
    • A comparison of wavelet and Joint Photographic Experts Group lossy compression methods applied to medical images
    • Iyriboz TA, Zukoski MJ, Hopper KD, et al: A comparison of wavelet and Joint Photographic Experts Group lossy compression methods applied to medical images. J Digit Imaging 12:14-17, 1999 (Suppl 1)
    • (1999) J Digit Imaging , vol.12 , Issue.1 SUPPL. , pp. 14-17
    • Iyriboz, T.A.1    Zukoski, M.J.2    Hopper, K.D.3
  • 8
    • 0034089298 scopus 로고    scopus 로고
    • Performance analysis of a new semiorthogonal spline wavelet compression algorithm for tonal medical images
    • Thompson SK, Hazle JD, Schomer DF, et al: Performance analysis of a new semiorthogonal spline wavelet compression algorithm for tonal medical images. Med Phys 27:276-288, 2000
    • (2000) Med Phys , vol.27 , pp. 276-288
    • Thompson, S.K.1    Hazle, J.D.2    Schomer, D.F.3
  • 9
  • 10
    • 0031195551 scopus 로고    scopus 로고
    • Evaluation of irreversible compression of digitized posterior-anterior chest radiographs
    • Erickson BJ, Manduca A, Persons KR, et al: Evaluation of irreversible compression of digitized posterior-anterior chest radiographs. J Digit Imaging 10:97-102, 1997
    • (1997) J Digit Imaging , vol.10 , pp. 97-102
    • Erickson, B.J.1    Manduca, A.2    Persons, K.R.3
  • 11
    • 0031883646 scopus 로고    scopus 로고
    • Detection of subtle abnormalities on chest radiographs after irreversible compression
    • Savcenko V, Erickson BJ, Palisson PM, et al: Detection of subtle abnormalities on chest radiographs after irreversible compression. Radiology 206:609-616, 1998
    • (1998) Radiology , vol.206 , pp. 609-616
    • Savcenko, V.1    Erickson, B.J.2    Palisson, P.M.3
  • 12
    • 0031021235 scopus 로고    scopus 로고
    • Focal hepatic lesions: Effect of three-dimensional wavelet compression on detection at CT
    • Goldberg MA, Gazelle GS, Boland GW, et al: Focal hepatic lesions: Effect of three-dimensional wavelet compression on detection at CT. Radiology 202:159-165, 1997
    • (1997) Radiology , vol.202 , pp. 159-165
    • Goldberg, M.A.1    Gazelle, G.S.2    Boland, G.W.3
  • 13
    • 0034146474 scopus 로고    scopus 로고
    • Effect of CT digital image compression on detection of coronary artery calcification
    • Zheng LM, Sone S, Itani Y, et al: Effect of CT digital image compression on detection of coronary artery calcification. Acta Radiol 41:116-121, 2000
    • (2000) Acta Radiol , vol.41 , pp. 116-121
    • Zheng, L.M.1    Sone, S.2    Itani, Y.3
  • 14
    • 0032730595 scopus 로고    scopus 로고
    • Best parameters selection for wavelet packet-based compression of magnetic resonance images
    • Abu-Rezq AN, Tolba AS, Khuwaja GA, et al: Best parameters selection for wavelet packet-based compression of magnetic resonance images. Comput Biomed Res 32:449-469, 1999
    • (1999) Comput Biomed Res , vol.32 , pp. 449-469
    • Abu-Rezq, A.N.1    Tolba, A.S.2    Khuwaja, G.A.3
  • 16
    • 0031962305 scopus 로고    scopus 로고
    • Statistical comparison of two ROC curve estimates obtained from partially-paired datasets
    • Metz CE, Herman BA, Roe CA: Statistical comparison of two ROC curve estimates obtained from partially-paired datasets. Med Decis Making 18:110-121, 1998
    • (1998) Med Decis Making , vol.18 , pp. 110-121
    • Metz, C.E.1    Herman, B.A.2    Roe, C.A.3
  • 17
    • 0029302603 scopus 로고
    • JPEG compression of digital echocardiographic images: Impact on image quality
    • Karson TH, Chandra S, Morehead AJ, et al: JPEG compression of digital echocardiographic images: Impact on image quality. J Am Soc Echocardiogr 8:306-318, 1995
    • (1995) J Am Soc Echocardiogr , vol.8 , pp. 306-318
    • Karson, T.H.1    Chandra, S.2    Morehead, A.J.3
  • 18
    • 0032129196 scopus 로고    scopus 로고
    • Clinical evaluation of irreversible data compression for computed radiography of the hand
    • Uchida K, Watanabe H, Aoki T, et al: Clinical evaluation of irreversible data compression for computed radiography of the hand. J Digit Imaging 11:121-125, 1998
    • (1998) J Digit Imaging , vol.11 , pp. 121-125
    • Uchida, K.1    Watanabe, H.2    Aoki, T.3
  • 19
    • 0030095040 scopus 로고    scopus 로고
    • Impact of lossy image compression on accuracy of caries detection in digital images taken with a storage phosphor system
    • Wenzel A, Gottredsen E, Borg E, et al: Impact of lossy image compression on accuracy of caries detection in digital images taken with a storage phosphor system. Oral Surg Med Pathol Radiol Endodont 81:351-355, 1996
    • (1996) Oral Surg Med Pathol Radiol Endodont , vol.81 , pp. 351-355
    • Wenzel, A.1    Gottredsen, E.2    Borg, E.3
  • 20
    • 0031195511 scopus 로고    scopus 로고
    • An analytical look at the effects of compression on medical images
    • Persons K, Palisson P, Manduca A, et al: An analytical look at the effects of compression on medical images. J Digit Imaging 10:60-66, 1997 (Suppl 1)
    • (1997) J Digit Imaging , vol.10 , Issue.1 SUPPL. , pp. 60-66
    • Persons, K.1    Palisson, P.2    Manduca, A.3
  • 21
    • 0024354748 scopus 로고
    • Full-frame transform compression of CT and MR images
    • Chan KK, Lou SL, Huang HK: Full-frame transform compression of CT and MR images. Radiology 171:847-851, 1989
    • (1989) Radiology , vol.171 , pp. 847-851
    • Chan, K.K.1    Lou, S.L.2    Huang, H.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.