메뉴 건너뛰기




Volumn 25, Issue 11, 2000, Pages 1457-1459

Femoral artery ischemia during spinal scoliosis surgery detected by posterior tibial nerve somatosensory-evoked potential monitoring

Author keywords

Femoral artery; Ischemia; Monitoring; Posterior tibial nerve; Somatosensory evoked potentials; Spinal cord; Surgery; Surgical complication

Indexed keywords

ADOLESCENT; ARTICLE; CASE REPORT; EVOKED SOMATOSENSORY RESPONSE; FEMORAL ARTERY; HUMAN; LEG ISCHEMIA; MALE; PATIENT MONITORING; PRIORITY JOURNAL; SPINAL CORD SURGERY; SURGICAL TECHNIQUE; TIBIAL NERVE; WAVEFORM;

EID: 0034214038     PISSN: 03622436     EISSN: None     Source Type: Journal    
DOI: 10.1097/00007632-200006010-00021     Document Type: Article
Times cited : (23)

References (11)
  • 1
    • 0033561463 scopus 로고    scopus 로고
    • External iliac artery occlusion in posterior spinal surgery
    • Akagi S, Yoshida Y, Kato I et al. External iliac artery occlusion in posterior spinal surgery. Spine 1999;24:823-5.
    • (1999) Spine , vol.24 , pp. 823-825
    • Akagi, S.1    Yoshida, Y.2    Kato, I.3
  • 2
    • 0023734457 scopus 로고
    • Changes in venous blood lactate, venous blood gases and somatosensory evoked potentials after tourniquet application
    • Benzon HT, Toeikis JR, Meagher LL et al. Changes in venous blood lactate, venous blood gases and somatosensory evoked potentials after tourniquet application. Anesthesiology 1988;69:677-82.
    • (1988) Anesthesiology , vol.69 , pp. 677-682
    • Benzon, H.T.1    Toeikis, J.R.2    Meagher, L.L.3
  • 3
    • 0031607752 scopus 로고    scopus 로고
    • Spinal cord protection during surgical procedures on the descending thoracic and thoracoabdominal aorta: A critical overview
    • Gharagozloo F, Neville RF, Cox JC. Spinal cord protection during surgical procedures on the descending thoracic and thoracoabdominal aorta: A critical overview. Sem Thoracic Cardiovasc Surg 1998;10:73-86.
    • (1998) Sem Thoracic Cardiovasc Surg , vol.10 , pp. 73-86
    • Gharagozloo, F.1    Neville, R.F.2    Cox, J.C.3
  • 4
    • 0030032140 scopus 로고    scopus 로고
    • The risk of ischemic spinal cord injury in patients undergoing graft replacement for thoracoabdominal aortic aneurysms
    • Grabitz K, Sandmann W, Stuhmeier K, et al. The risk of ischemic spinal cord injury in patients undergoing graft replacement for thoracoabdominal aortic aneurysms. J Vasc Surg 1996;23:230-40.
    • (1996) J Vasc Surg , vol.23 , pp. 230-240
    • Grabitz, K.1    Sandmann, W.2    Stuhmeier, K.3
  • 5
    • 0032899578 scopus 로고    scopus 로고
    • Strategies to prevent neurologic deficit based on motor-evoked potentials in type I and II thoracoabdominal aortic aneurysm repair
    • Jacobs MJMH, Meylaerts SA, de Haan P, de Mol BA, Kalkman CJ. Strategies to prevent neurologic deficit based on motor-evoked potentials in type I and II thoracoabdominal aortic aneurysm repair. J Vasc Surg 1999;29:48-57.
    • (1999) J Vasc Surg , vol.29 , pp. 48-57
    • Jacobs, M.J.M.H.1    Meylaerts, S.A.2    De Haan, P.3    De Mol, B.A.4    Kalkman, C.J.5
  • 6
    • 0025959738 scopus 로고
    • Monitoring of spinal cord stimulation evoked potentials during thoracoabdominal aneurysm surgery
    • North RB, Drenger B, Beattie C, et al. Monitoring of spinal cord stimulation evoked potentials during thoracoabdominal aneurysm surgery. Neurosurgery 1991;28:325-30.
    • (1991) Neurosurgery , vol.28 , pp. 325-330
    • North, R.B.1    Drenger, B.2    Beattie, C.3
  • 7
    • 0028881660 scopus 로고
    • Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: Results of a large multicenter study
    • Nuwer MR, Dawson EG, Carlson LG, Kanim LEA, Sherman JE. Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: Results of a large multicenter study. Electroencephalogr Clin Neurophysiol 1995;96:6-11.
    • (1995) Electroencephalogr Clin Neurophysiol , vol.96 , pp. 6-11
    • Nuwer, M.R.1    Dawson, E.G.2    Carlson, L.G.3    Kanim, L.E.A.4    Sherman, J.E.5
  • 8
    • 0031815006 scopus 로고    scopus 로고
    • Spinal cord monitoring with somatosensory techniques
    • Nuwer MR. Spinal cord monitoring with somatosensory techniques. J Clin Neurophysiol 1998;15:183-93.
    • (1998) J Clin Neurophysiol , vol.15 , pp. 183-193
    • Nuwer, M.R.1
  • 9
    • 0031815007 scopus 로고    scopus 로고
    • Anesthetic effects in electrophysiologic recordings
    • Sloan TB. Anesthetic effects in electrophysiologic recordings. J Clin Neurophysiol 1998;15:217-26.
    • (1998) J Clin Neurophysiol , vol.15 , pp. 217-226
    • Sloan, T.B.1
  • 10
    • 0027477143 scopus 로고
    • The effect of lower limb ischemia on somatosensory evoked potentials during spinal surgery. Report of two cases and review of the literature
    • Trammell TR, Friedlander JK, Reed DB. The effect of lower limb ischemia on somatosensory evoked potentials during spinal surgery. Report of two cases and review of the literature. Spine 1993;18:413-5.
    • (1993) Spine , vol.18 , pp. 413-415
    • Trammell, T.R.1    Friedlander, J.K.2    Reed, D.B.3
  • 11
    • 0019820980 scopus 로고
    • Tourniquet-induced ischemia and somatosensory evoked potentials
    • Yamada T, Muroga T, Kimura J. Tourniquet-induced ischemia and somatosensory evoked potentials. Neurology 1981;31:1524-9.
    • (1981) Neurology , vol.31 , pp. 1524-1529
    • Yamada, T.1    Muroga, T.2    Kimura, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.