Volumn 78, Issue 4, 2000, Pages 605-611

On-line monitoring for multiloop control systems under load disturbance

Author keywords

L(c,max); Multiloop control system; On line monitoring; Relay bias; Relay feedback

Indexed keywords

CLOSED LOOP CONTROL SYSTEMS; COMPUTER SIMULATION; FEEDBACK CONTROL; MATHEMATICAL MODELS; MIXING; NONLINEAR CONTROL SYSTEMS; ONLINE SYSTEMS; OSCILLATIONS;

EID: 0034190660     PISSN: 02638762     EISSN: None     Source Type: Journal    
DOI: 10.1205/026387600527545     Document Type: Article
Times cited : (1)

References (12)
  • 2
    • 0024750457 scopus 로고
    • Assessment of control loop performance
    • Harris, T. J., 1989, Assessment of control loop performance, Canad J Chem Eng, 61: 856-861.
    • (1989) Canad J Chem Eng , vol.61 , pp. 856-861
    • Harris, T.J.1
  • 3
    • 0027545302 scopus 로고
    • Monitoring and diagnosing process control performance: The single-loop case
    • Stanfelj, N., Marlin, T. E. and MacGregor, J. F., 1993, Monitoring and diagnosing process control performance: The single-loop case, Ind Eng Chem Res, 32: 301-314.
    • (1993) Ind Eng Chem Res , vol.32 , pp. 301-314
    • Stanfelj, N.1    Marlin, T.E.2    MacGregor, J.F.3
  • 4
    • 0027138294 scopus 로고
    • Monitoring procedure for intelligent control: On-line identification of maximum closed-loop log modulus
    • Chiang, R. C. and Yu, C. C., 1993, Monitoring procedure for intelligent control: On-line identification of maximum closed-loop log modulus, Ind Eng Chem Res, 32: 90-99.
    • (1993) Ind Eng Chem Res , vol.32 , pp. 90-99
    • Chiang, R.C.1    Yu, C.C.2
  • 5
    • 0029192306 scopus 로고
    • Closed-loop estimation of robustness margins by the relay method
    • Longchamp, R. and Piguet, Y., 1995, Closed-loop estimation of robustness margins by the relay method, Proc American Control Conf, 2687-2691.
    • (1995) Proc American Control Conf , pp. 2687-2691
    • Longchamp, R.1    Piguet, Y.2
  • 6
    • 0031169244 scopus 로고    scopus 로고
    • Relay-based on-line monitoring procedure for 2 x 2 and 3 x 3 multiloop control systems
    • Ju, J. and Chiu, M. S., 1997, Relay-based on-line monitoring procedure for 2 x 2 and 3 x 3 multiloop control systems, Ind Eng Chem Res, 36: 2225-2230.
    • (1997) Ind Eng Chem Res , vol.36 , pp. 2225-2230
    • Ju, J.1    Chiu, M.S.2
  • 7
    • 0032033711 scopus 로고    scopus 로고
    • An on-line monitoring procedure for 2 x 2 and 3 x 3 full multivariable control systems
    • Ju, J. and Chiu, M. S., 1998, An on-line monitoring procedure for 2 x 2 and 3 x 3 full multivariable control systems, Chem Eng Sci, 53: 1277-1293.
    • (1998) Chem Eng Sci , vol.53 , pp. 1277-1293
    • Ju, J.1    Chiu, M.S.2
  • 8
    • 0031162425 scopus 로고    scopus 로고
    • Controller performance assessment by frequency domain techniques
    • Kendra, S. J. and Cinar, A., 1997, Controller performance assessment by frequency domain techniques, J Proc Cont, 7: 181-194.
    • (1997) J Proc Cont , vol.7 , pp. 181-194
    • Kendra, S.J.1    Cinar, A.2
  • 11
    • 0030151784 scopus 로고    scopus 로고
    • Autotune identification under load disturbance
    • Shen, S. H., Wu, J. S. and Yu, C. C., 1996, Autotune identification under load disturbance, Ind Eng Chem Res, 35: 1642-1651.
    • (1996) Ind Eng Chem Res , vol.35 , pp. 1642-1651
    • Shen, S.H.1    Wu, J.S.2    Yu, C.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.