메뉴 건너뛰기




Volumn 53, Issue 6, 1998, Pages 1277-1293

An on-line monitoring procedure for 2 x 2 and 3 x 3 full multivariable control systems

Author keywords

Full multivariable controller; Maximum closed loop log modulus; Monitoring procedure; PI controller; Relay feedback; Robustness

Indexed keywords

CLOSED LOOP CONTROL SYSTEMS; CONTROL SYSTEM SYNTHESIS; FEEDBACK CONTROL; LINEAR CONTROL SYSTEMS; MULTIVARIABLE CONTROL SYSTEMS; NONLINEAR CONTROL SYSTEMS; ROBUSTNESS (CONTROL SYSTEMS); TWO TERM CONTROL SYSTEMS;

EID: 0032033711     PISSN: 00092509     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0009-2509(97)00413-2     Document Type: Article
Times cited : (5)

References (13)
  • 2
    • 0027138294 scopus 로고
    • Monitoring procedure for intelligent control: On-line identification of maximum closed-loop log modulus
    • Chiang R. C., Yu C. C. Monitoring procedure for intelligent control. on-line identification of maximum closed-loop log modulus Ind. Engng Chem. Res. 32:1993;90-99.
    • (1993) Ind. Engng Chem. Res. , vol.32 , pp. 90-99
    • Chiang, R.C.1    Yu, C.C.2
  • 3
    • 0024302326 scopus 로고
    • Control of distillation columns with low relative volatilities
    • Finco M. V., Luyben W. L., Polleck R. E. Control of distillation columns with low relative volatilities. Ind. Engng. Chem. Res. 28:1989;75-83.
    • (1989) Ind. Engng. Chem. Res. , vol.28 , pp. 75-83
    • Finco, M.V.1    Luyben, W.L.2    Polleck, R.E.3
  • 4
    • 0024750457 scopus 로고
    • Assessment of control loop performance
    • Harris T. J. Assessment of control loop performance. Can. J. Chem. Engng. 67:1989;856-861.
    • (1989) Can. J. Chem. Engng , vol.67 , pp. 856-861
    • Harris, T.J.1
  • 6
    • 0031169244 scopus 로고    scopus 로고
    • Relay-based on-line monitoring procedures for 2+2 and 3+3 multiloop control systems
    • Ju J., Chiu M. S. Relay-based on-line monitoring procedures for 2+2 and 3+3 multiloop control systems. Ind. Engng Chem. Res. 36:1997;2225-2230.
    • (1997) Ind. Engng Chem. Res. , vol.36 , pp. 2225-2230
    • Ju, J.1    Chiu, M.S.2
  • 7
    • 0028480071 scopus 로고
    • Describing function matrix for multivariable system and its use in multiloop PI design
    • Loh A. P., Vasnani V. U. Describing function matrix for multivariable system and its use in multiloop PI design. J. Proc. Cont. 4:1994;114-120.
    • (1994) J. Proc. Cont. , vol.4 , pp. 114-120
    • Loh, A.P.1    Vasnani, V.U.2
  • 10
    • 0020782356 scopus 로고
    • Advanced multivariable control of a pilot plant distillation column
    • Ogunnaike B. A., Lemaire J. P., Morari M., Ray W. H. Advanced multivariable control of a pilot plant distillation column. A.I.Ch.E. J. 29:1983;632-640.
    • (1983) A.I.Ch.E. J. , vol.29 , pp. 632-640
    • Ogunnaike, B.A.1    Lemaire, J.P.2    Morari, M.3    Ray, W.H.4
  • 11
    • 0041778585 scopus 로고
    • Multivariable process control - A survey
    • Ray W. H. Multivariable process control - a survey. Comput. Chem. Engng. 7:1983;367-394.
    • (1983) Comput. Chem. Engng , vol.7 , pp. 367-394
    • Ray, W.H.1
  • 12
    • 0027545302 scopus 로고
    • Monitoring and diagnosing process control performance: The single-loop case
    • Stanfelj N., Marlin T. E., MacGregor J. F. Monitoring and diagnosing process control performance. the single-loop case Ind. Engng Chem. Res. 32:1993;301-314.
    • (1993) Ind. Engng Chem. Res. , vol.32 , pp. 301-314
    • Stanfelj, N.1    Marlin, T.E.2    MacGregor, J.F.3
  • 13
    • 0019559036 scopus 로고
    • Feedback and optimal sensitivity: Model reference transformations, multiplicative seminorms and approximate inverses
    • Zames G. Feedback and optimal sensitivity. model reference transformations, multiplicative seminorms and approximate inverses IEEE Trans. Autom. Control. AC 26:1981;301-320.
    • (1981) IEEE Trans. Autom. Control , vol.26 , pp. 301-320
    • Zames, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.