메뉴 건너뛰기




Volumn 41, Issue 4, 2000, Pages 692-699

Transmission scanning system for a γ camera coincidence scanner

Author keywords

camera; 137Cs; Attenuation correction

Indexed keywords

CESIUM 137; FLUORODEOXYGLUCOSE;

EID: 0034109786     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (17)
  • 1
    • 0029784885 scopus 로고    scopus 로고
    • PET imaging using gamma camera systems: A review
    • Jarritt PH, Acton PD. PET imaging using gamma camera systems: a review. Nucl Med Commun. 1996;17:758-766.
    • (1996) Nucl Med Commun , vol.17 , pp. 758-766
    • Jarritt, P.H.1    Acton, P.D.2
  • 2
    • 0342445583 scopus 로고    scopus 로고
    • 511 keV imaging: SPECT, coincidence, or both?
    • Smith EM, O'Mara RE. 511 keV imaging: SPECT, coincidence, or both? Appl Radiology. 1996;25:6-27.
    • (1996) Appl Radiology , vol.25 , pp. 6-27
    • Smith, E.M.1    O'Mara, R.E.2
  • 3
    • 0032976092 scopus 로고    scopus 로고
    • FDG imaging of lung nodules: A phantom study comparing SPECT, camera-based PET, and dedicated PET
    • Coleman RE, Laymon CM, Turkington TG. FDG imaging of lung nodules: a phantom study comparing SPECT, camera-based PET, and dedicated PET. Radiology. 1999;210:823-828.
    • (1999) Radiology , vol.210 , pp. 823-828
    • Coleman, R.E.1    Laymon, C.M.2    Turkington, T.G.3
  • 5
    • 0029063786 scopus 로고
    • Single photon transmission measurements in positron tomography using Cs-137
    • Yu SK, Nahmias C. Single photon transmission measurements in positron tomography using Cs-137. Phys Med Biol. 1995;40:1255-1266.
    • (1995) Phys Med Biol , vol.40 , pp. 1255-1266
    • Yu, S.K.1    Nahmias, C.2
  • 8
    • 0016088183 scopus 로고
    • The reduction of coincidence loss in radionuclide imaging cameras through the use of composite filters
    • Muehllehner G, Jaszczak RJ, Beck RN. The reduction of coincidence loss in radionuclide imaging cameras through the use of composite filters. Phys Med Biol. 1974;19:504-510.
    • (1974) Phys Med Biol , vol.19 , pp. 504-510
    • Muehllehner, G.1    Jaszczak, R.J.2    Beck, R.N.3
  • 9
    • 0013454225 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. J Nucl Med. 1994;39:601-609.
    • (1994) J Nucl Med , vol.39 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 10
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • Lange K, Carson R. EM reconstruction algorithms for emission and transmission tomography. J Comput Assist Tomogr. 1984;8:306-316.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 11
    • 0021952059 scopus 로고
    • Fast calculation of the exact radiological path for a three-dimensional CT array
    • Siddon RL. Fast calculation of the exact radiological path for a three-dimensional CT array. Med Phys. 1985;12:252-255.
    • (1985) Med Phys , vol.12 , pp. 252-255
    • Siddon, R.L.1
  • 12
    • 0031864145 scopus 로고    scopus 로고
    • Transmission imaging for nonuniform attenuation correction using a three-headed SPECT camera
    • Gilland DR, Jaszczak RJ, Greer KL, Coleman RE. Transmission imaging for nonuniform attenuation correction using a three-headed SPECT camera. J Nucl Med. 1998;39:1105-1110.
    • (1998) J Nucl Med , vol.39 , pp. 1105-1110
    • Gilland, D.R.1    Jaszczak, R.J.2    Greer, K.L.3    Coleman, R.E.4
  • 13
    • 0003017412 scopus 로고
    • Photon cross-sections, attenuation coefficients, and energy absorption coefficients from 10 keV to 100 GeV
    • Hubbell JH. Photon cross-sections, attenuation coefficients, and energy absorption coefficients from 10 keV to 100 GeV. Natl Stand Ref Data Ser. 1969;29:62-66.
    • (1969) Natl Stand Ref Data Ser , vol.29 , pp. 62-66
    • Hubbell, J.H.1
  • 14
    • 0028341310 scopus 로고
    • Attenuation correction in PET using single photon transmission measurement
    • deKemp RA, Nahmias C. Attenuation correction in PET using single photon transmission measurement. Med Phys. 1994;21:771-778.
    • (1994) Med Phys , vol.21 , pp. 771-778
    • DeKemp, R.A.1    Nahmias, C.2
  • 15
    • 0033315059 scopus 로고    scopus 로고
    • Multiple point sources collimated with transaxial septa for high energy gamma camera transmission scanning
    • Turkington TG, Laymon CM, Schopfer KG, Coleman RE, Wainer N. Multiple point sources collimated with transaxial septa for high energy gamma camera transmission scanning. IEEE Trans Nucl Sci. 1999;46:2247-2252.
    • (1999) IEEE Trans Nucl Sci , vol.46 , pp. 2247-2252
    • Turkington, T.G.1    Laymon, C.M.2    Schopfer, K.G.3    Coleman, R.E.4    Wainer, N.5
  • 17
    • 0027391737 scopus 로고
    • Attenuation correction using count-limited transmission data in positron emission tomography
    • Meickle SR, Dahlbom M, Cherry SR. Attenuation correction using count-limited transmission data in positron emission tomography. J Nucl Med. 1993;34:143-150.
    • (1993) J Nucl Med , vol.34 , pp. 143-150
    • Meickle, S.R.1    Dahlbom, M.2    Cherry, S.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.