메뉴 건너뛰기




Volumn 45, Issue 6 PART 2, 1998, Pages 3115-3121

Attenuation effects in gamma-camera coincidence imaging

Author keywords

[No Author keywords available]

Indexed keywords

IMAGE ANALYSIS; IMAGE QUALITY; MEDICAL COMPUTING; MEDICAL IMAGING; PATTERN MATCHING; POSITRON EMISSION TOMOGRAPHY; SIGNAL TO NOISE RATIO;

EID: 0032309912     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/23.737673     Document Type: Article
Times cited : (10)

References (19)
  • 1
    • 84908720720 scopus 로고    scopus 로고
    • Performance parameters of a positron imaging camera, IEEE Trans Nucl Sei vol. 23, pp. 528-537, 1976.
    • G. Muchllehncr, M.P. Buchin, S.H. Dudek, Performance parameters of a positron imaging camera, IEEE Trans Nucl Sei vol. 23, pp. 528-537, 1976.
    • S.H. Dudek
    • Muchllehncr, G.1    Buchin, M.P.2
  • 3
    • 33747383911 scopus 로고    scopus 로고
    • Coincidence mode imaging using a standard dualheaded gamma camera, J Nucl Med vol. 37, p 223, 1996.
    • R.S. Miyaoka, W.L.S. Costa, T.K. Lewellen, et al, Coincidence mode imaging using a standard dualheaded gamma camera, J Nucl Med vol. 37, p 223, 1996.
    • Miyaoka, R.S.1    Costa, W.L.S.2    Lewellen, T.K.3
  • 5
    • 0029806321 scopus 로고    scopus 로고
    • Untreated lung cancer: quantification of systematic distortion of tumor size and shape on nonattenuation-corrected 2-[fluorine-18]fluoro-2-deoxy-n-glucose PHT scans
    • K.R. Zasadny, P.V. Kison, L.E. Quint, R.L. Wahl, Untreated lung cancer: quantification of systematic distortion of tumor size and shape on nonattenuation-corrected 2-[fluorine-18]fluoro-2-deoxy-n-glucose PHT scans, Radiology vol. 201. pp. 873-876, 1997.
    • Radiology Vol. 201. Pp. 873-876, 1997.
    • Zasadny, K.R.1    Kison, P.V.2    Quint, L.E.3    Wahl, R.L.4
  • 7
    • 33747382767 scopus 로고    scopus 로고
    • Initial Comparison of the accuracy of attenuation corrected vs. nonattenuation corrected FDG PET scans in evaluating the thorax of patients with suspected non-small cell lung cancer
    • R.L. Wahl, P Kison, P Shreve, Initial Comparison of the accuracy of attenuation corrected vs. nonattenuation corrected FDG PET scans in evaluating the thorax of patients with suspected non-small cell lung cancer, J Nucl Med, vol. 38, pp. 5P-6P, May 1997.
    • J Nucl Med, Vol. 38, Pp. 5P-6P, May 1997.
    • Wahl, R.L.1    Kison, P.2    Shreve, P.3
  • 8
    • 33747387620 scopus 로고    scopus 로고
    • Advance PET scanner is manufactured by General Electric Inc., Milwaukee, WI.
    • Advance PET scanner is manufactured by General Electric Inc., Milwaukee, WI.
  • 9
    • 33747407344 scopus 로고    scopus 로고
    • VariCam coincidence gamma camera is manufactured by Elscint Ltd., Haifa, Israel.
    • VariCam coincidence gamma camera is manufactured by Elscint Ltd., Haifa, Israel.
  • 10
    • 33747391579 scopus 로고    scopus 로고
    • Thorax phantom manufactured by Data Spectrum Corp., Hillsboro, NC.
    • Thorax phantom manufactured by Data Spectrum Corp., Hillsboro, NC.
  • 16
    • 0030214069 scopus 로고    scopus 로고
    • Post-injection transmission scans in a PET camera operating without septa with simultaneous measurement of emission activity contamination
    • R.J. Smith and J.S. Karp, Post-injection transmission scans in a PET camera operating without septa with simultaneous measurement of emission activity contamination, IEEE Trans Nucl Sei, vol. 43, pp. 2207-2212, 1996.
    • IEEE Trans Nucl Sei, Vol. 43, Pp. 2207-2212, 1996.
    • Smith, R.J.1    Karp, J.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.