메뉴 건너뛰기




Volumn 10, Issue 2, 2000, Pages 297-303

Precision of tibial cartilage morphometry with a coronal water- excitation MR sequence

Author keywords

Cartilage; Joint; MR imaging; Osteoarthritis; Precision

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; FUNCTIONAL ANATOMY; HUMAN; IMAGE ANALYSIS; MALE; MORPHOMETRICS; NUCLEAR MAGNETIC RESONANCE IMAGING; OSTEOARTHRITIS; PATHOLOGICAL ANATOMY; PRIORITY JOURNAL; REPRODUCIBILITY; TIBIA;

EID: 0034107773     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s003300050047     Document Type: Article
Times cited : (57)

References (23)
  • 1
    • 0028874943 scopus 로고
    • The economic cost and social and psychological impact of musculoskeletal conditions
    • Yelin E, Callaghan LF (1995) The economic cost and social and psychological impact of musculoskeletal conditions. Arthritis Rheum 38: 1351-1362
    • (1995) Arthritis Rheum , vol.38 , pp. 1351-1362
    • Yelin, E.1    Callaghan, L.F.2
  • 2
    • 0001360184 scopus 로고
    • Über die Arthritis deformans
    • Heine J (1926) Über die Arthritis deformans. Arch Pathol Anat:521-663
    • (1926) Arch Pathol Anat , pp. 521-663
    • Heine, J.1
  • 3
    • 0013587855 scopus 로고
    • Osteoarthritis. The epidemiologic viewpoint
    • Peyron JG (1986) Osteoarthritis. The epidemiologic viewpoint. Clin Orthop 13: 213-218
    • (1986) Clin Orthop , vol.13 , pp. 213-218
    • Peyron, J.G.1
  • 4
    • 0030885051 scopus 로고    scopus 로고
    • Articular cartilage. Part II. Degeneration and osteoarthrosis, repair, regeneration, and transplantation
    • Buckwalter JA, Mankin HJ (1997) Articular cartilage. Part II. Degeneration and osteoarthrosis, repair, regeneration, and transplantation. J Bone Joint Surg 79A:612-632
    • (1997) J Bone Joint Surg , vol.79 A , pp. 612-632
    • Buckwalter, J.A.1    Mankin, H.J.2
  • 6
    • 0028059347 scopus 로고
    • Quantification of articular cartilage in the knee with pulsed saturation transfer subtraction and fat-suppressed MR imaging: Optimization and validation
    • Peterfy CG, van Dijke DF, Janzen DL, Glüer CC, Namba R, Majumdar S, Lang P, Genant HK (1994) Quantification of articular cartilage in the knee with pulsed saturation transfer subtraction and fat-suppressed MR imaging: optimization and validation. Radiology 192: 485-491
    • (1994) Radiology , vol.192 , pp. 485-491
    • Peterfy, C.G.1    Van Dijke, D.F.2    Janzen, D.L.3    Glüer, C.C.4    Namba, R.5    Majumdar, S.6    Lang, P.7    Genant, H.K.8
  • 7
    • 0030043472 scopus 로고    scopus 로고
    • Articular cartilage volume in the knee: Semiautomatic determination from three-dimensional reformations of MR images
    • Piplani MA, Disler DG, McCauley TR, Holmes TJ, Cousins JP (1996) Articular cartilage volume in the knee: semiautomatic determination from three-dimensional reformations of MR images. Radiology 198: 855-859
    • (1996) Radiology , vol.198 , pp. 855-859
    • Piplani, M.A.1    Disler, D.G.2    McCauley, T.R.3    Holmes, T.J.4    Cousins, J.P.5
  • 9
    • 0030967791 scopus 로고    scopus 로고
    • A non-invasive technique for 3-dimensional assessment of articular cartilage thickness based on MRI. Part II. Validation with CT arthrography
    • Haubner M, Eckstein F, Lösch A, Schnier M, Sittek H, Becker C, Kolem H, Reiser M, Englmeier K-H (1997) A non-invasive technique for 3-dimensional assessment of articular cartilage thickness based on MRI. Part II. Validation with CT arthrography. Magn Reson Imaging 15: 805-813
    • (1997) Magn Reson Imaging , vol.15 , pp. 805-813
    • Haubner, M.1    Eckstein, F.2    Lösch, A.3    Schnier, M.4    Sittek, H.5    Becker, C.6    Kolem, H.7    Reiser, M.8    Englmeier, K.-H.9
  • 11
    • 0030921706 scopus 로고    scopus 로고
    • A non-invasive technique for 3-dimensional assessment of articular cartilage thickness based on MRI. Part I. Development of a computational method
    • Lösch A, Eckstein F, Haubner M, Englmeier KH (1997) A non-invasive technique for 3-dimensional assessment of articular cartilage thickness based on MRI. Part I. Development of a computational method. Magn Reson Imaging 15: 795-804
    • (1997) Magn Reson Imaging , vol.15 , pp. 795-804
    • Lösch, A.1    Eckstein, F.2    Haubner, M.3    Englmeier, K.H.4
  • 12
    • 0032999913 scopus 로고    scopus 로고
    • Determination of 3D cartilage thickness data from MR imaging: Computational method and reproducibility in the living
    • Stammberger T, Eckstein F, Englmeier K-H, Reiser M (1999) Determination of 3D cartilage thickness data from MR imaging: computational method and reproducibility in the living. Magn Reson Med 41: 529-536
    • (1999) Magn Reson Med , vol.41 , pp. 529-536
    • Stammberger, T.1    Eckstein, F.2    Englmeier, K.-H.3    Reiser, M.4
  • 14
    • 0022642386 scopus 로고
    • Should perimenopausal women be screened for osteoporosis?
    • Cummings SR, Black D (1986) Should perimenopausal women be screened for osteoporosis? Ann Intern Med 104: 817-823
    • (1986) Ann Intern Med , vol.104 , pp. 817-823
    • Cummings, S.R.1    Black, D.2
  • 15
    • 0026215143 scopus 로고
    • The impact of measurement errors on the diagnostic value of bone density measurements: Theoretical considerations
    • Hassager C, Jensen B, Gotfredsen A, Christiansen C (1991) The impact of measurement errors on the diagnostic value of bone density measurements: theoretical considerations. Osteoporosis Int 1: 250-256
    • (1991) Osteoporosis Int , vol.1 , pp. 250-256
    • Hassager, C.1    Jensen, B.2    Gotfredsen, A.3    Christiansen, C.4
  • 16
    • 0029112340 scopus 로고
    • Accurate assessment of precision errors: How to measure the reproducibility of bone densitometry techniques
    • Glüer CC, Blake G, Lu Y, Blunt BA, Jergas M, Genant HK (1995) Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques. Osteoporosis Int 5: 262-270
    • (1995) Osteoporosis Int , vol.5 , pp. 262-270
    • Glüer, C.C.1    Blake, G.2    Lu, Y.3    Blunt, B.A.4    Jergas, M.5    Genant, H.K.6
  • 18
    • 0032824770 scopus 로고    scopus 로고
    • Interobserver reproducibility of quantitative cartilage measurements: Comparsion between B-spline snakes and manual segmentation
    • in press
    • Stammberger T, Eckstein F, Michaelis M, Englmeier K-H, Reiser M (1999) Interobserver reproducibility of quantitative cartilage measurements: comparsion between B-spline snakes and manual segmentation. Magn Reson Imaging (in press)
    • (1999) Magn Reson Imaging
    • Stammberger, T.1    Eckstein, F.2    Michaelis, M.3    Englmeier, K.-H.4    Reiser, M.5
  • 19
    • 0013941871 scopus 로고
    • The intraclass correlation coefficient as a measure of reliability
    • Bartko JJ (1966) The intraclass correlation coefficient as a measure of reliability. Psychol Rep 19: 3-11
    • (1966) Psychol Rep , vol.19 , pp. 3-11
    • Bartko, J.J.1
  • 20
    • 0028596182 scopus 로고
    • Assessment of cartilage volume in the femorotibial joint with magnetic resonance imaging and 3D computer reconstruction
    • Pilch L, Stewart C, Gordon D, Inman R, Parsons K, Pataki I, Stevens J (1994) Assessment of cartilage volume in the femorotibial joint with magnetic resonance imaging and 3D computer reconstruction. J Rheumatol 21: 2307-2319
    • (1994) J Rheumatol , vol.21 , pp. 2307-2319
    • Pilch, L.1    Stewart, C.2    Gordon, D.3    Inman, R.4    Parsons, K.5    Pataki, I.6    Stevens, J.7
  • 21
    • 0343501525 scopus 로고    scopus 로고
    • A rapid 3D FLASH water excitation sequence for quantification of articular cartilage volume and thickness by MRI: Optimization and validation
    • Glaser C, Eckstein F, Faber S, Englmeier K-H, Reiser M (1999) A rapid 3D FLASH water excitation sequence for quantification of articular cartilage volume and thickness by MRI: optimization and validation. Eur Radiol 9:C25
    • (1999) Eur Radiol , vol.9
    • Glaser, C.1    Eckstein, F.2    Faber, S.3    Englmeier, K.-H.4    Reiser, M.5
  • 22
    • 1642641518 scopus 로고    scopus 로고
    • High-resolution, selective water-excitation MR imaging for quantitative assessment of thin cartilage layers: Validation with CT-arthrography and A-mode ultrasound
    • in press
    • Graichen H, Springer V, Flamann T, Stammberge T, Glaser C, Englmeier K-H, Reiser M, Eckstein F (1999) High-resolution, selective water-excitation MR imaging for quantitative assessment of thin cartilage layers: validation with CT-arthrography and A-mode ultrasound. Osteoarthritis Cart (in press)
    • (1999) Osteoarthritis Cart
    • Graichen, H.1    Springer, V.2    Flamann, T.3    Stammberge, T.4    Glaser, C.5    Englmeier, K.-H.6    Reiser, M.7    Eckstein, F.8
  • 23
    • 0031277817 scopus 로고    scopus 로고
    • Repeatability of patellar cartilage thickness patterns in the living, using a fat-suppressed MRI sequence with short acquisition time and 3D data processing
    • Tieschky M, Faber S, Haubner M, Kolem H, Schulte E, Englmeier K-H, Reiser M, Eckstein F (1997) Repeatability of patellar cartilage thickness patterns in the living, using a fat-suppressed MRI sequence with short acquisition time and 3D data processing. J Orthop Res 15: 808-813
    • (1997) J Orthop Res , vol.15 , pp. 808-813
    • Tieschky, M.1    Faber, S.2    Haubner, M.3    Kolem, H.4    Schulte, E.5    Englmeier, K.-H.6    Reiser, M.7    Eckstein, F.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.