메뉴 건너뛰기




Volumn 26, Issue 4, 2000, Pages 629-639

Quantification of microbubble destruction of three fluorocarbon-filled ultrasonic contrast agents

Author keywords

Definity ; DMP115; Echocardiography; NC100100; Optison ; Sonazoid ; Tissue mimicking phantom; Ultrasonic contrast agents; Ultrasound

Indexed keywords

BLOOD VESSELS; BUBBLE FORMATION; CONTRAST MEDIA; FLUOROCARBONS; TISSUE; ULTRASONIC DEVICES; ULTRASONIC SCATTERING; ULTRASONIC VELOCITY;

EID: 0034076974     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(00)00148-4     Document Type: Article
Times cited : (46)

References (19)
  • 2
    • 0028985912 scopus 로고
    • The effect of an elastic solid surface layer on the radial pulsations of gas bubbles
    • Church C.C. The effect of an elastic solid surface layer on the radial pulsations of gas bubbles. J Acoust Soc Am. 97:1995;1510-1521.
    • (1995) J Acoust Soc Am , vol.97 , pp. 1510-1521
    • Church, C.C.1
  • 4
    • 0032212255 scopus 로고    scopus 로고
    • Myocardial contrast echocardiography: Too much, too soon?
    • DeMaria A.N., Cotter B. Myocardial contrast echocardiography too much, too soon? J Am Coll Cardiol. 32:1998;1270-1271.
    • (1998) J Am Coll Cardiol , vol.32 , pp. 1270-1271
    • Demaria, A.N.1    Cotter, B.2
  • 5
    • 0032969632 scopus 로고    scopus 로고
    • Scattering properties of encapsulated gas bubbles at high ultrasound pressures
    • Frinking P.J.A., de Jong N., Cespedes E.I. Scattering properties of encapsulated gas bubbles at high ultrasound pressures. J Acoust Soc Am. 105:1999;1989-1996.
    • (1999) J Acoust Soc Am , vol.105 , pp. 1989-1996
    • Frinking, P.J.A.1    De Jong, N.2    Cespedes, E.I.3
  • 7
    • 0032480764 scopus 로고    scopus 로고
    • Assessment of transmural distribution of myocardial perfusion with contrast echocardiography
    • Linka A.Z., Sklenar J., Wei K., Jayaweera A.R., Skyba D.M., Kaul S. Assessment of transmural distribution of myocardial perfusion with contrast echocardiography. Circulation. 98:1998;1912-1920.
    • (1998) Circulation , vol.98 , pp. 1912-1920
    • Linka, A.Z.1    Sklenar, J.2    Wei, K.3    Jayaweera, A.R.4    Skyba, D.M.5    Kaul, S.6
  • 9
    • 0032126027 scopus 로고    scopus 로고
    • Quantification of the enhanced backscatter phenomenon from an intravenous and an intra-arterial contrast agent
    • Moran C.M., Anderson T., Sboros V., Sutherland G.R., Wright R., McDicken W.N. Quantification of the enhanced backscatter phenomenon from an intravenous and an intra-arterial contrast agent. Ultrasound Med Biol. 24:1998;871-880.
    • (1998) Ultrasound Med Biol , vol.24 , pp. 871-880
    • Moran, C.M.1    Anderson, T.2    Sboros, V.3    Sutherland, G.R.4    Wright, R.5    McDicken, W.N.6
  • 10
    • 0033035902 scopus 로고    scopus 로고
    • Potential advantage of flash echocardiography for digital subtraction of B-mode images acquired during myocardial contrast echocardiography
    • Pelberg R.A., Wei K., Kamiyama N., Sklenar J., Bin J., Kaul S. Potential advantage of flash echocardiography for digital subtraction of B-mode images acquired during myocardial contrast echocardiography. J Am Soc Echocardiog. 12:1999;85-93.
    • (1999) J Am Soc Echocardiog , vol.12 , pp. 85-93
    • Pelberg, R.A.1    Wei, K.2    Kamiyama, N.3    Sklenar, J.4    Bin, J.5    Kaul, S.6
  • 11
    • 0028882611 scopus 로고
    • Transient myocardial contrast after initial exposure to diagnostic ultrasound pressures with minute does of intravenously injected microbubbles
    • Porter T.R., Xie F. Transient myocardial contrast after initial exposure to diagnostic ultrasound pressures with minute does of intravenously injected microbubbles. Circulation. 92:1995;2391-2395.
    • (1995) Circulation , vol.92 , pp. 2391-2395
    • Porter, T.R.1    Xie, F.2
  • 12
    • 0030889485 scopus 로고    scopus 로고
    • Detection of myocardial perfusion in multiple echocardiographic windows with one intravenous injection of microbubbles using transient response second harmonic imaging
    • Porter T.R., Shouping L., Kricsfeld D., Armbruster R.W. Detection of myocardial perfusion in multiple echocardiographic windows with one intravenous injection of microbubbles using transient response second harmonic imaging. J Am Coll Cardiol. 29:1997;791-799.
    • (1997) J Am Coll Cardiol , vol.29 , pp. 791-799
    • Porter, T.R.1    Shouping, L.2    Kricsfeld, D.3    Armbruster, R.W.4
  • 13
    • 0026535688 scopus 로고
    • Simulated capillary blood flow measurement using a non-linear ultrasonic contrast agent
    • Schrope B., Newhouse V.L., Uhlendorf V. Simulated capillary blood flow measurement using a non-linear ultrasonic contrast agent. Ultrasonic Imaging. 14:1992;134-158.
    • (1992) Ultrasonic Imaging , vol.14 , pp. 134-158
    • Schrope, B.1    Newhouse, V.L.2    Uhlendorf, V.3
  • 14
    • 0033096935 scopus 로고    scopus 로고
    • Pulse inversion Doppler: A new method for detecting non-linear echoes from microbubble contrast agents
    • Simpson D.H., Chin D.T., Burns P.N. Pulse inversion Doppler a new method for detecting non-linear echoes from microbubble contrast agents . IEEE Trans Ultrason Ferroelec Freq Control. 40:1999;372-382.
    • (1999) IEEE Trans Ultrason Ferroelec Freq Control , vol.40 , pp. 372-382
    • Simpson, D.H.1    Chin, D.T.2    Burns, P.N.3
  • 15
    • 0032970496 scopus 로고    scopus 로고
    • Persistent opacification of the left ventricle and myocardium with a new echo contrast agent
    • Strauss A.L., Beller K.D. Persistent opacification of the left ventricle and myocardium with a new echo contrast agent. Ultrasound Med Biol. 25:1999;763-769.
    • (1999) Ultrasound Med Biol , vol.25 , pp. 763-769
    • Strauss, A.L.1    Beller, K.D.2
  • 18
    • 0032501992 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion
    • Wei K., Jayaweera A.R., Firoozan S., Linka A., Skyba D.M., Kaul S. Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation. 97:1998;473-480.
    • (1998) Circulation , vol.97 , pp. 473-480
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3    Linka, A.4    Skyba, D.M.5    Kaul, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.